ATMOS D 14 P COM
Code: D14P COMProduct detailed description
- 4-14 kW compact ecological automatic pellet boiler
ATMOS D14P COM is supplied as a complete set with a stainless steel connection (boiler circuit with a 70°C thermal valve + one pump group with a 3-way valve without a servo drive) and with a ATMOS A25 pellet burner.
- the boiler is designed for perfect pellet combustion so that a pellet burner is built into the left or right side of the boiler, depending on the customer's needs, which fully automatically draws pellets from the storage tank using a screw conveyor. The fuel storage tank is usually located next to the boiler or in an adjacent room and can be of any size (standard 250, 500 or 1000L). A part of the boiler room is also often used as a fuel storage tank, which is then enough for the whole heating season.
Operation of the pellet burner is completely automatic. If the burner receives a start signal or if heating is needed, the conveyor feeds pellets into the burner nozzle and ignites them itself with a heating element (spiral). After sufficient ignition of the pellets, the burner runs up to the set output, at which it remains until the system (house) is heated. Then the burner switches off and the pellets in the burner chamber burn out completely. The burner is thus ready for a new start. The whole cycle repeats itself whenever needed again.
The boiler output and other burner functions are controlled by electronic regulation, which allows the boiler operation to be adapted to the specific conditions of the whole system. Refilling pellets, cleaning the burner's combustion chamber and removing ash is done once every 1 – 30 days, depending on the quality of the pellets and the size of the storage tank.
If needed, boilers can be equipped with an automatic ash removal system for comfortable heating with minimal operation.
|
Basic technical data of Atmos D14P:
Note: The boiler is supplied with two KTF20 - 5m sensors (DHW and HW). |
| Accessories needed for the boiler: | |
![]() DA screw conveyor - various lengths |
![]() pellet storage tank - various |
|
Advantages of ATMOS pellet boilers:
|
Frequently Asked Questions
- How to choose the right output for a solid fuel boiler? Base your choice on the calculated heat loss of the heated building, but for wood/coal boilers also consider that the boiler burns for several hours at essentially constant output during one filling - therefore it is common practice to supplement the boiler with a buffer tank, which stores excess heat for later use instead of the boiler having to be inefficiently throttled down.
- What else do I need to install this boiler? In addition to the boiler itself, the system usually requires: a buffer (equalizing) tank of appropriate volume, a circulation pump (often already with a built-in Laddomat or thermoregulatory valve against low-temperature corrosion of the boiler), a safety valve, an expansion vessel and a flue/chimney with sufficient draft corresponding to the boiler output - you can find the exact chimney draft values in the technical parameters above.
- What fuel is suitable and what is not? Use only fuel recommended by the manufacturer for the given model (usually split logs of a defined length and moisture content, or brown coal briquettes or coal depending on the boiler type) - unsuitable or too moist fuel reduces efficiency, increases the formation of tar and deposits and can damage the boiler.
- What about chimney inspection and legislation? Before putting the boiler into operation, as well as regularly during its use (usually once a year for solid fuels), a chimney inspection/cleaning by an authorized chimney sweep is required by law - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputed.
- How much maintenance does the boiler require? This normally includes regular ash removal and cleaning of the heating surfaces/flue gas paths from soot (interval depending on intensity of use, usually a matter of weeks), and once a year a thorough inspection including seals and the chimney.
- Can I install the boiler myself? The actual placement and connection of the boiler to the heating system, chimney and safety elements should be carried out or at least professionally checked by a heating technician - this is a device with open flame, high temperatures and pressure elements, where an installation error can be a safety risk.
Additional parameters
| Category: | KOMPAKT boilers |
|---|---|
| Warranty: | 2 years |
| Weight: | 258 kg |
| Boiler output: | 4 – 14 kW |
| Boiler weight: | 231 kg |
| Combustion Class: | 5 |
| Combustion chamber volume: | 88 dm³ |
| Dimensions (H / W / D): | 1207/ 620 /768 mm |
| Efficiency: | 90,3% |
| Energy efficiency class: | A+ |
| Heating surface: | 1,7m 2 |
| Max. water working pressure: | 250 kPa |
| Minimum buffer tank volume: | 500L |
| Objem vody v kotli: | 56 L |
| Required chimney draught: | 16 Pa |