- 19kW the most modern wood gasification boiler – DOKOGEN COMFORT with automatic ignition and ACD04 equithermal control with a touch display
- the Dokogen type features a special firebox lined on both sides with ceramic mouldings, fitted at the bottom with openings for the supply of preheated primary air, a gasification nozzle with openings for secondary air supply, and a lower combustion chamber with a spherical ceramic space. The rear flue gas duct is fitted with a tube heat exchanger.
Gasification of wood (reverse-down burning) with subsequent combustion of the wood gas in the ceramic combustion space ensures optimal burnout of all combustible substances. Air supply and the combustion process are controlled by the extraction fan. This allows the boiler to fire up quickly and burn well right from the start. The flame temperature is 1000 – 1250 °C. Reverse-down combustion and the ceramic combustion space enable practically perfect combustion with a minimum of harmful emissions. The boilers meet the limits for an environmentally friendly product.
Automatic ignition is used for immediate or scheduled boiler firing according to a time programme (e.g. before arriving home, or before arriving at a cottage), or according to the buffer tank temperature. Fuel ignition is very fast (approx. 5 min) and lets you arrive to a warm house already.
Simple and quick firing is ensured by an ignition coil using a small amount of pellets (a handful).
An automatic wood-ignition device (a chamber with a 500W glowing coil) is built in between the upper and lower doors. Quality wood pellets are used for ignition, filling the chamber. The amount of pellets corresponds to the size of the scoop supplied with the boiler.
Basic technical data Atmos DC18GD ZAP:
|
Note: This boiler can also be purchased in the standard version- i.e. without automatic ignition
and without the ACD04 equithermal control unit, here: ATMOS DC18GD
Advantages of ATMOS wood gasification boilers :
|
Frequently asked questions
- How do I choose the right output for a solid fuel boiler? Base it on the calculated heat loss of the building being heated. For wood/coal boilers, however, also consider that the boiler burns for several hours per load at essentially constant output - it is therefore common practice to add a buffer (accumulation) tank, which stores surplus heat for later use instead of forcing the boiler to be inefficiently throttled down.
- What else do I need to install this boiler? Besides the boiler itself, the system usually requires: a buffer (accumulation) tank of adequate volume, a circulation pump (often already fitted with a Laddomat or a thermoregulating valve to protect the boiler against low-temperature corrosion), a safety valve, an expansion vessel, and a flue/chimney with sufficient draught corresponding to the boiler’s output - you’ll find the exact chimney draught values in the technical parameters above.
- What fuel is suitable and what isn’t? Use only the fuel recommended by the manufacturer for the given model (typically split logs of a defined length and moisture content, or brown-coal briquettes or coal depending on the boiler type) - unsuitable or overly damp fuel reduces efficiency, increases tar and deposit build-up, and can damage the boiler.
- What about chimney inspections and legislation? Before commissioning the boiler, and regularly during its use (usually once a year for solid fuels), the law requires the chimney to be inspected/cleaned by a certified chimney sweep - without the relevant inspection certificate, an insurance claim in the event of a fire could also be disputed.
- How much maintenance does the boiler need? This usually involves regularly removing ash and cleaning soot from the heating surfaces/flue gas passages (the interval depends on how intensively the boiler is used, typically a matter of weeks), plus a thorough annual check including the seals and chimney.
- Can I install the boiler myself? Positioning the boiler and connecting it to the heating system, chimney and safety components should be carried out, or at least professionally checked, by a heating technician - this is equipment with an open flame, high temperatures and pressurised components, where a connection error can be a safety risk.
Additional parameters
| Category: | with ACD04 weather-compensated control |
|---|---|
| Warranty: | 2 years |
| Weight: | 445.05 kg |
| Objem vody: | 73 L |
| Boiler weight: | 376 kg |
| Combustion Class: | 5 |
| Efficiency: | 90,3% |
| Energy efficiency class: | A+ |
| Hopper volume: | 80 dm³ |
| Max. log length: | 330 mm |
| Minimum return water temperature: | 65 °C |
| Output: | 19 kW |
| Prescribed fuel: | dry wood with calorific value 15 - 18 MJ/kg, diameter 80 - 150 mm and moisture 12-20 % |
| Required chimney draught: | 16 Pa |