- 35kW ecological wood gasification boiler - WOOD GAS boiler with built-in ACD04 equithermal control unit with touch display


It is designed for burning wood on the principle of generator gasification using an exhaust fan (S), which extracts flue gases from the boiler. 
The boiler body is made as a welded construction from high-quality steel sheets 3 to 8 mm thick. It consists of a fuel hopper (6mm), which is fitted at the bottom with a gasification nozzle with a longitudinal opening for the passage of flue gases and gases. The afterburner chamber below it is equipped with ceramic shaped parts for ideal burnout of all combustible substances with high efficiency in ecologically friendly combustion. At the rear of the boiler body there is a vertical flue gas duct, which is fitted at the top with a starting flap. The upper part of the flue gas duct is fitted with an exhaust neck for connection to the chimney.  

Basic technical data of Atmos DC32S REG: 

  • output: 35 kW
  • efficiency: 88.9%
  • prescribed chimney draught: 24 Pa
  • boiler weight: 366 kg
  • water volume: 80 L
  • hopper volume: 135 dm3
  • max. wood length: 530 mm
  • prescribed fuel: dry wood with calorific value 15 – 18 MJ/kg,
    diameter 80 – 150 mm and moisture 12 -20 %
  • minimum return water temperature: 65 °C
  • suitable connection ATMOS F2 Laddomat, ATMOS F4 ESBE 
  • combustion class: 5
  • energy efficiency class: A+
  • the equithermal control unit ACD04 with touch display is built directly into the panel of this boiler,
    which can control
    besides the boiler itself also the boiler circuit, three heating circuits, DHW heating,  solar system, etc. It is a functionally identical control unit as the separately sold Equithermal control unit ACD03

Note:This boiler can also be purchased in the classic version with standard control (i.e. without the ACD04 equithermal control unit) ATMOS DC32S, or in the version with automatic ignition and electronic control AC32, boiler ATMOS DC32S ZAP

Advantages of ATMOS wood gasification boilers:

  • possibility to burn large pieces of wood
  • large fuel hopper = long burning time
  • high efficiency 
  • ecological combustion - boiler according to ČSN EN 303-5 class 4 and 5, ECODESIGN 2015/1189
  • exhaust fan - dust-free ash removal, boiler room without smoke 
  • cooling loop against overheating - no risk of boiler damage
  • automatic boiler shutdown after fuel burnout - flue gas thermostat
  • convenient ash removal - large ceramic combustion chamber for ash (with wood, ash is removed once a week)
  • boiler without a tube heat exchanger - easier cleaning
  • small dimensions and low weight
  • high quality 

 

Frequently Asked Questions

  • How to choose the correct output for a solid fuel boiler? Base your choice on the calculated heat loss of the heated building, but for wood/coal boilers also consider that the boiler burns for several hours at essentially constant output during one filling - it is therefore common practice to supplement the boiler with a storage tank, which stores excess heat for later use instead of the boiler having to be inefficiently throttled down.
  • What else do I need to install this boiler? In addition to the boiler itself, the system usually requires: a storage (buffer) tank of appropriate volume, a circulation pump (often already with a built-in Laddomat or thermoregulation valve against low-temperature corrosion of the boiler), a safety valve, an expansion vessel, and a flue/chimney with sufficient draught corresponding to the boiler output - exact draught values can be found in the technical parameters above.
  • What fuel is suitable and what is not? Use only the fuel recommended by the manufacturer for the given model (usually piece wood of defined length and moisture content, or brown coal briquettes or coal depending on the boiler type) - unsuitable or too moist fuel reduces efficiency, increases tar and deposit formation and can cause damage to the boiler.
  • What about chimney inspection and legislation? Before putting the boiler into operation, as well as regularly during its use (usually once a year for solid fuels), a chimney inspection/cleaning by an authorized chimney sweep is legally required - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputable.
  • How much maintenance does the boiler require? This usually includes regular removal of ash and cleaning of heating surfaces/flue gas passages from soot (interval depending on intensity of use, usually in the order of weeks), and once a year a thorough inspection including seals and the chimney.
  • Can I install the boiler myself? The actual placement and connection of the boiler to the heating system, chimney and safety elements should be carried out or at least professionally checked by a heating technician - this is a device with open flame, high temperatures and pressurized elements, where an error in connection can be a safety risk.

Additional parameters

Category: with ACD04 weather-compensated control
Warranty: 2 years
Weight: 420.9 kg
Objem vody: 80 L
Boiler weight: 366 kg
Combustion Class: 5
Efficiency: 88,9%
Energy efficiency class: A+
Hopper capacity: 135 dm³
Max. log length: 530 mm
Minimum return water temperature: 65 °C
Output: 35 kW
Prescribed fuel: dry wood with calorific value 15 - 18 MJ/kg, diameter 80 - 150 mm and moisture 12-20 %
Required chimney draught: 24 Pa

Product rating