Atmos Sibral Insulation for Large Door - Thick
Code: S0264Product detailed description
for the upper door of DC75SE, DC100, DC105S, DC150S, D14P, D21P, D25P, D31P, DCxxGSX, GSXxx, P14-P31, D21 boilers
Original Sibral Insulation for the Large Door, Atmos S0264:
- Thickness: 42 mm
- The package includes 2 washers and 2 M6x45 mm screws
Note:
If you need to replace the Sibral door lining on your boiler, you will likely also need to replace the sealing cord located in a separate groove around this lining. You can order the sealing cord for the large door here: 18x18 sealing cord for the large door
Frequently asked questions
- How do I choose the right output for a solid-fuel boiler? Base your choice on the calculated heat loss of the heated building; for wood/coal boilers also consider that the boiler burns for several hours at essentially constant output during a single load - which is why it's common practice to add a buffer (accumulation) tank to the boiler, storing surplus heat for later use instead of having to inefficiently throttle the boiler.
- What else do I need to install this boiler? Besides the boiler itself, the system usually requires: a buffer (accumulation) tank of adequate volume, a circulation pump (often already fitted with a built-in Laddomat or thermoregulatory valve against low-temperature corrosion of the boiler), a safety valve, an expansion vessel, and a flue/chimney with sufficient draught matching the boiler's output - you'll find the exact chimney draught values in the technical parameters above.
- What fuel is suitable, and what isn't? Use only fuel recommended by the manufacturer for the given model (typically split logs of a defined length and moisture content, or brown-coal briquettes or coal depending on the boiler type) - unsuitable or overly damp fuel reduces efficiency, increases tar and deposit build-up, and can damage the boiler.
- What about chimney inspection and legislation? Before putting the boiler into operation, and regularly during its use (typically once a year for solid fuels), the chimney must, by law, be inspected/cleaned by an authorised chimney sweep - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputed.
- How much maintenance does the boiler require? This usually includes regularly removing ash and cleaning the heating surfaces/flue-gas passages of soot (interval depending on intensity of use, typically on the order of weeks), plus a thorough annual inspection including seals and the chimney.
- Can I install the boiler myself? The actual placement and connection of the boiler to the heating system, chimney and safety components should be carried out, or at least professionally checked, by a heating technician - this is an appliance with an open flame, high temperatures and pressurised components, where a connection error can be a safety risk.
Additional parameters
| Category: | Spare parts for doors |
|---|---|
| Warranty: | 2 years |
| Weight: | 1.909 kg |
| Thickness: | 42 mm |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
