AVANSA UPS 1050W 24V Backup Power Supply for Circulation Pumps, Pure Sine Wave Replacement Power Source for Boilers and Heating
Code: PR_117511Product detailed description
This backup power supply can be used to ensure the operation of other electrical appliances that require stable and steady electrical power parameters. However, it should not be used as a converter (for unlimited operation from a 24V battery). The main feature of this device is the input power curve during battery operation. The curve is a pure sine wave, identical to the main power grid supply in your home. When the main power from your home is on, the backup power supply will charge the battery and ensure its long service life. The backup power supply (UPS) works only with an external 12V battery (for the 1050 W model, a 24V battery). Only a lead-acid type battery should be used, as the backup power supply is designed for charging this type of battery. The use of gel batteries is not recommended. WARNING! When connecting the backup power supply, remove any metal objects (e.g. bracelets, chains, watches, rings, etc.). This is because a short circuit of electrical current may occur, followed by scattering of metal materials on the user's body. When connecting the battery, maintain the correct polarity: red (+positive) - the cable will be connected to the + terminal, and black (-negative) - the wire will be connected to the - terminal. Metal connectors are used to connect the cable to the battery terminals. Before connecting, it is recommended to clean the battery contacts with a brush. Tighten the connector using a wrench to ensure a firm contact. Install the backup power supply (UPS) in a dry place, free of moisture, away from water or snow. The installation location of the backup power supply (UPS) must be large enough not to obstruct the cooling system of the backup power supply. Furthermore, this location should be free of dust or coal dust, which could block the fan of the backup power supply. The installation location should be well ventilated to prevent the system from overheating. To avoid electric shock, check that all cables are in good condition and free of uninsulated parts. Operation of the backup power supply (UPS) may cause sparking. The backup power supply should not be installed in flammable environments. WARNING! The backup power supply (UPS) works only when connected to an external battery. It should not be used without a battery connected. After connecting the battery, plug the main power cable into a grounded socket (230V, 50 Hz). On the back of the unit, connect the device that you want to keep running during a power outage. Follow this sequence: connect the battery, connect the main power supply, and then connect the consumer (device) to the backup power supply (UPS). To turn the unit on, press and hold the power button (ON/OFF) for 4 seconds. The system operation begins with automatic detection of the battery status of the mains voltage. If the battery voltage drops below 10.8V, the battery may be damaged and cannot be started. In the event of a power outage, or if its parameters are not within the normal range, the backup power supply (UPS) will automatically switch to the battery. The switch of the backup power supply to the battery is displayed on the screen of the backup power supply (UPS). The device (UPS) also announces the switch of the backup power supply (UPS) to battery with an audible signal. WARNING! This is only a safety device that is used only in the event of a power outage. When using this device, please do not leave it near fuel. Technical data: maximum capacity: 1500 VA maximum rated power: 1050W main input power: 150 – 270 VAC input frequency: 45 – 65 Hz output power: 207 – 241 VAC input frequency: 50 – 60 Hz switching time: <4ms battery capacity: 24V DC overload protection: 110%, 130% (30 seconds) standby power consumption: 22W dimensions (H/W/D): 18.5x14.5x34 cm The backup power supply is suitable for appliances with a combined rated power of approx. max. 500 W For a consumption of 100W: the backup power supply (UPS) with a 65 Ah battery will run for 3.5 hours the backup power supply (UPS) with a 120 Ah battery will run for 6.5 hours the backup power supply (UPS) with a 150 Ah battery will run for 8 hours For a consumption of 200W: the backup power supply (UPS) with a 65 Ah battery will run for 2 hours the backup power supply (UPS) with a 120 Ah battery will run for 3 hours the backup power supply (UPS) with a 150 Ah battery will run for 4 hours For a consumption of 300W: the backup power supply (UPS) with a 65 Ah battery will run for 1.5 hours the backup power supply (UPS) with a 120 Ah battery will run for 2.5 hours the backup power supply (UPS) with a 150 Ah battery will run for 3 hoursAdditional parameters
| Category: | Backup Power Supplies for Circulation Pumps |
|---|---|
| EAN: | 5949040800216 |
| Dimensions H x W x D (cm): | 18,5x14,5x34 |
| EAN: | 5949040800216 |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!