Battery combiner Cyrix-ct 12-24V 120A
Code: TI_04290039Product detailed description
Battery combiner Cyrix-ct 12-24V 120A
The intelligent Cyrix-ct battery combiner controls the connection and disconnection of the starter and service batteries. If the voltage on one of the batteries reaches 13.0 V (26 V) for 10 minutes or 13.8 V (27.6 V) for 4 seconds, the Cyrix-ct connects the batteries and both batteries are charged simultaneously to a full state. As soon as the voltage on one of the batteries drops below 12.8 V (25.6 V) for 10 minutes or 11.8 V (23.6 V) for 4 seconds, the batteries are disconnected from each other. This connecting and disconnecting works bidirectionally. The batteries can be of different capacities, types and constructions. It is assumed that each battery supplies its own loads.
The Cyrix-ct model is equipped with temperature protection. In case of high ambient temperature or excessive charging current, it will switch off. As soon as the temperature drops, the Cyrix-ct activates automatically.
Basic wiring options can be found in the attached file "Wiring Diagrams" below.
Product parameters:
Operating voltage: 12 or 24 V (auto-detection)
Maximum current from alternator: 150 A
Maximum continuous current in system: 120 A
Current consumption when device is not switched on: 4 mA
Connection voltage (with a delay of approximately 10 minutes): 13 V / 26 V
Connection voltage (with a delay of approximately 4 seconds): 13.8 V / 27.6 V
Disconnection voltage (with a delay of approximately 10 minutes): 12.8 V / 25.6 V
Disconnection voltage (with a delay of approximately 4 seconds): 11.8 V / 23.6 V
Overvoltage disconnection: 16 V (32 V)
Dimensions without terminals: 45 x 45 x 45 mm
Housing material: black plastic
Protection rating: IP54
Additional parameters
| Category: | Photovoltaics |
|---|---|
| Warranty: | 2 years |
| EAN: | 8719076022138 |