Control unit PC-16 with pressure gauge, Press Control for pumps and home water systems
Code: PR_38411Product detailed description
The PC-16 control unit with pressure gauge and dry-run auto-restart for controlling pump operation performs the function of a pressure switch or pressure tank, enabling automatic operation of submersible or self-priming (surface) pumps. Depending on a drop in pressure and the stopping of water flow in the system, it allows the pump or water system to run automatically. With the PC-16 control unit you DO NOT NEED a pressure tank (watering, irrigation), a pressure switch, or dry-run protection. If you need to use water every day, use a Home Water System with a pressure tank. Or a home water system with a self-priming - surface pump - darling. The PC-16 control unit with pressure gauge provides dry-run protection - it switches off the pump when running without water. This protects the pump from damage that could otherwise occur. The PC-16 control unit automatically, without manual intervention, tries to restart the pump - if water is still not available, the PC-16 switches the pump off. This cycle can repeat several times a day, which can be an advantage for automatic irrigation. We recommend using the PC-16 control unit with pressure gauge and dry-run auto-restart in clean water systems without impurities and sediments, otherwise a suitable filter must be installed. Product advantages: automatic dry-run restart usability with pumps (as an automatic unit) built-in electrical socket for connecting the pump Operation - basic data: The PC-16 control unit with pressure gauge and dry-run auto-restart starts the pump running for approximately 15 seconds at the moment of connection. The pump then starts every time the operating pressure is reached, at the moment the pressure in the system drops, for example after a valve is opened, and also during dry-run auto-restart. On the PC-16 control unit, the lower switch-on pressure is adjustable - the upper switch-off pressure cannot be set - once switched on, it works up to the pump's maximum. The PC-16 control unit with pressure gauge and dry-run auto-restart can be installed at any point between the pump and the first point of use. The system must ensure a perfect seal of all joints. Technical data: Power supply 230V Maximum current 10A; 1.1kW Maximum permissible pressure 10bar Maximum liquid temperature 55°C Connections: inlet/ outlet G 1" 1m cable with plug for connection to the electrical mains Plug for connecting the pump When used with pumps that generate a pressure higher than 6 BAR, we recommend installing a pressure reducing valve before the control unit.Additional parameters
| Category: | Control Units, PRESS CONTROL |
|---|---|
| Weight: | 1.5 kg |
| EAN: | 5903111344566 |
| Connection size: | 1" x 1" |
| EAN: | 5903111344566 |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!