HAKL TCX 10/ 1230 W, cable

Code: HATCX101230
napojeny tovar
Not rated Rating details
189,63 € –10 %
TCX10
189,63 € –10 % 170,67 € / pcs Measure price:
In stock at supplier

Detailed information

Product detailed description

 

KEY FEATURES

  • designed for wet installation, embedded in a concrete mix
  • heating cable thickness 6 mm
  • suitable for ceramic tiles, glued vinyl flooring and more
  • fixed in place using fixing strips
  • protective cable braiding allows installation in damp areas
  • ideal for new buildings, higher concrete layer thickness 
  • can also be used as the main source of heat in a room
  • maintenance-free operation, no need for regular servicing
  • high-quality heating cores with a melting point of up to 1100 °C
  • every product undergoes a strict final output test

 


 

PRODUCT DESCRIPTION

Electric underfloor heating cables HAKL TCX 10 have a power input of 10 W per metre of cable. They are connected to the mains using a single connecting cable 3 metres long.  For the most efficient operation, it is recommended to install a HAKL TH thermostat with a floor sensor in each room. You can also save energy and money by choosing the right floor covering and providing sufficient thermal insulation under the underfloor heating. Thanks to maintenance-free operation, HAKL underfloor heating meets even the most demanding requirements for quality and comfort.
Before installation, the manufacturer recommends reading the installation manual carefully, where you will find a detailed description of the product and its wiring. 

 

Illustrative image of the wiring of HAKL TCX underfloor heating using a single connecting cable.

 


 

FLOOR STRUCTURE

Heating cables HAKL TCX 10 are designed for wet installation, embedded in a concrete mix with a maximum thickness of 8 cm. This floor structure achieves what is known as "STORAGE HEATING". The heating cable is placed under the concrete layer above the thermal insulation. This floor structure means that the accumulated thermal energy in the concrete radiates heat into the room for a long time after the heating is switched off. Heating cables HAKL TCX 10 are recommended for installation as the main heat source in new buildings, where increasing the floor height is not a problem.

Illustrative image of the floor structure: 
1. floor covering - tiles, 2. flexible adhesive mortar, 3. top concrete layer, 4. TCX heating cable,
5. fixing strip, 6. bottom concrete base, 7. underlay foil, 8. hardened polystyrene  

 


 

HEATING CABLE

Heating cables HAKL TCX feature a high-quality heating core - the resistance wire comes from the renowned Swedish manufacturer KANTHAL. The sheath of the TCX heating cable has a diameter of 6 mm. It is thicker than the cable used in the TF and TFX heating mats. A cable of this size withstands sharp stone fragments found in the concrete mix. It is made of a highly heat-resistant material that does not deform even during prolonged heating. When underfloor heating is connected without a thermostat, the heating cable heats up to a maximum of 65°C, while the melting point is up to 1100 °C. 
The heating cables themselves are protected by a dense metal protective braid, which increases their durability and allows installation in damp areas (bathroom, WC…)

Illustrative image, cross-section of the heating cable.

 


 

QUALITY CERTIFICATE

Every single heating cable undergoes an output load test, during which the joints are tested, insulation breakdown is measured, total cable resistance, etc...
This record of piece testing is stated in the Quality Certificate. The product must meet the parameters 100% before it can leave the production line. 

 

Illustrative image.

 


 

SUITABILITY TABLE

To make it easier to choose the right electric underfloor heating model, the manufacturer has prepared a clear suitability table.
Electric underfloor heating is divided into two main groups: electric heating cables and aluminium and mesh heating mats.
The heating cable group has a power input of 10 W per metre of cable. They are designed for wet installation, embedded in a concrete mix. This floor structure achieves what is known as "STORAGE HEATING".
The second group consists of aluminium and mesh heating mats, which have a power input of 100 to 150 W per square metre. They are designed for wet installation, embedded in adhesive mortar directly under the floor covering, or they can be laid loosely, without the need for embedding. This floor structure achieves what is known as "DIRECT HEATING".
When choosing electric underfloor heating, it is necessary to take the parameters of the building into account; in a new building it is possible to raise the floor by 5 to 8 cm by embedding the cables in a concrete mix, but for renovations the thickness for embedding in adhesive mortar is only about 1.5 cm. 
 

Note:
A simple selection and sorting of underfloor heating according to your own requirements is available in the main category using the filtering tool. 
 
 

Additional parameters

Category: Underfloor Heating|Heating Cables|TCX 10
Weight: 4.81 kg
EAN: 8586018642224
Manufacturer:: HAKL - assembled in Slovakia
Power input:: 1230 W
Voltage:: 230 V
Fuse protection:: 6 A
Current:: 5.35 A
Power input per W/m:: 10 W/m
Protection rating:: IP 67
Heating cable length:: 123 m
Connection cable length:: 3 m
Number of heating cables:: 2 pcs
Number of connection cables:: 1 pc
Direct heating:: no
Storage heating:: yes
Moisture protection:: yes
Net weight:: 4.75 kg
Gross weight:: 4.81 kg
Box dimensions:: 36 x 6.0 x 36 cm
EAN:: 8586018642224