Thermona THERM 28 TXZE.A

Code: 1045.8
Not rated Rating details
1 497,60 € –34 %
Thermona THERM 28 TXZE.A
1 497,60 € –34 % 979,20 € / pcs Measure price:
Sale ended or currently unavailable
The item has been sold out…

Detailed information

Product detailed description

Low-temperature wall-mounted boilers Thermona THERM 28 28 TXZE.A with the option of connecting an external tank

 

Chimney version

 

Boiler features and functions:

  • The new control electronics are designed with an emphasis on increased user comfort, a display integrated directly on the board, and the replacement of mechanical parameter switches with software settings secured by an entry code, etc.
  • The automation software has been updated and includes several patented solutions - e.g. a self-diagnostic system and fault evaluation
  • The board design places emphasis on higher reliability of the operating elements
  • The board includes a universal terminal block for both a room thermostat and an OpenTherm-communication controller (eliminating the need for the IU 02 unit)
  • The electronics include both hardware and software for controlling a boiler cascade
  • The software allows convenient service parameter settings via PC (authorised service only)
  • The DIMS 01 automation monitoring and tester can still be used (different connectors - wiring adapter pieces required)
  • For boilers with a tank, the software allows switching off domestic hot water (DHW) heating at the left end position of the DHW temperature control knob
  • Possibility of connection to a solar system

 

Improved features of the new boilers:

  • Suppression of EMC interference caused by the ignition spark and contact switching
  • Pump operation control, fan operation control
  • Flue gas discharge control by pressure switch or flue gas thermostat
  • Power supply of the safety and flue gas thermostat by safe low voltage
  • Provision of irreversible shutdown
  • Smooth flame modulation with PWM current regulator
  • Temperature control by PID-type regulation
  • Heating temperature monitoring by an NTC temperature sensor (continuous-flow water heating boilers only)
  • DHW temperature monitoring by an NTC temperature sensor
  • DHW tank thermostat input (heating of an indirect tank)
  • Communication with an external controller (OpenTherm) or cascade system (with IU04 and IU05 interfaces)
  • Communication port for a desktop or laptop computer for boiler monitoring and setting of operating parameters
  • Optional integrated weather-compensated control using an external temperature sensor
  • Information menu for checking operating parameters
  • Setting of boiler operating parameters (setup menu)
  • Boiler configuration setting after entering an access code (setup menu 2)
  • Fault detection via the history menu
  • Three rotary controls for selecting the operating mode, the desired heating temperature and the desired DHW temperature (continuous-flow heating only)
  • Monitoring of heating water flow, or pressure, by a flow/pressure switch

 

TECHNICAL DATAunit28LXZE.A 
Heat output for heating min-maxkW12-28 
Nominal heat output for DHW heatingkW28
Natural gas consumptionm3/h1,40-3,25
Max. overpressure of heating systembar3
Max. inlet pressure DHWbar6
Boiler efficiency%92
Nominal electrical inputW120
Protection rating of electrical parts-IP 44
Expansion vessel volumel10
Flue diameter *mm130
Boiler weightkg38
Dimensions: height / width / depthmm830/430/367

Additional parameters

Category: Thermona
Warranty: 2 years
Product replaced by new one:: https://www.atria.sk/protherm-panther-condens-25-kko-model-2021/
The item has been sold out…

Product rating

Be the first who will post an article to this item!

Do not fill out this field:

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field:
Vytvořil Shoptet | Design Shoptak.cz. > >