Vaillant 2.0" connection insulation for allSTOR exclusiv
Code: 0010015142Product detailed description
Vaillant 2.0" connection insulation — thermal insulation for the cylinder connection neck
The original 2.0" connection insulation from Vaillant is a small but functionally important accessory for multi-purpose cylinders of the allSTOR exclusiv range and other Vaillant systems that use connection necks with a nominal diameter of 2.0 inches. It is a shaped insulating shell that fits directly onto the metal connection neck of the cylinder, at the point where it joins the piping of the heating or solar circuit, or the domestic hot water circuit. Although it may at first glance seem like a negligible detail, it is precisely at the connection point where one of the most significant thermal bridges on the entire cylinder occurs — the metal flange or threaded joint conducts heat many times faster than the surrounding tank shell insulation, and without additional insulation, a surprisingly large amount of energy can escape through several such necks, especially with year-round operation of a cylinder kept at operating temperature.
Why insulating connections matters
Modern storage and multi-purpose cylinders, such as the allSTOR exclusiv range, come from the factory equipped with quality thermal insulation of the shell — usually soft foam or a stiffer shaped layer several centimetres thick, which significantly limits heat loss into the surrounding boiler room or utility room. However, for design reasons, this shell insulation cannot cover the connection necks themselves — i.e. the points where threaded or flanged outlets for the flow and return piping, hot water circulation, heat pump connection, solar circuit, or an additional heat source exit the tank. It is precisely here, directly on the metal, where uninsulated heat loss occurs, which — with multiple connections on a single cylinder — can accumulate into a measurable operating loss over the course of a year. That is why Vaillant offers separate insulation for individual connections, sized exactly to match the diameter of the given neck — in this case 2.0 inches — in order to achieve as complete a thermal insulation envelope as possible for the whole cylinder, including its connection points.
Investing in additional insulation of the connections pays off especially for cylinders that are in operation practically continuously (for example central storage tanks combining a heat pump, solar circuit, and hot water preparation), because even a small difference in daily heat loss multiplies over the number of days in a year. At the same time, this measure is in line with common practice in energy-efficient installations and the recommendations of heating system designers — thoroughly insulating all accessible hot-water surfaces, including fittings and connections, is one of the standard steps in optimizing the operating costs of the heating system of a house, apartment building, or smaller facility.
Additional effect — reducing condensation and protecting surfaces
In addition to direct energy savings, the connection insulation also serves a second, often overlooked function — it reduces the risk of surface condensation on cooler piping sections (for example on the return side of a colder solar or heat-pump circuit), thereby lowering the risk of long-term dampness around the cylinder, moisture on metal parts, and, in extreme cases, corrosion on unprotected metal components in the boiler room. In utility rooms with limited ventilation, this aspect can be just as important as the energy saving itself, since prolonged moisture near electrical switchboards, control equipment, or circulation pumps shortens their service life.
Technical design and material
The 2.0" connection insulation is designed as a shaped shell made of closed-cell foam (typically based on expanded polypropylene/EPP or a similar thermal insulation material also used on the main shell of Vaillant cylinders), which is simply slid or clipped around the connection neck and, if necessary, tightened or secured against slipping. The material is chosen to withstand long-term exposure to elevated temperatures near hot-water piping in the utility room, while also meeting fire-safety requirements common for spaces with heat sources — when installing in a boiler room, care should therefore be taken to ensure the insulation is not exposed to direct contact with an open flame or with surfaces significantly hotter than the material is rated for. The exact dimensions of the shell correspond to the nominal connection diameter of 2.0 inches, ensuring a tight fit without gaps through which warm air could escape.
Installation — what to watch out for
Fitting the insulating shell itself is a simple task that, on a new installation, is carried out by the installation company together with connecting the piping to the cylinder — the insulation is slid onto the neck either before or immediately after the pipe connection, depending on the specific design of the given connection. When retrofitting an already operating system, a brief shutdown of the circuit concerned should be expected, in order to avoid burns when handling the hot surface of the neck. We recommend entrusting the installation to a qualified plumber or heating system service technician, who can also use the opportunity to check the tightness of the connection itself, the tightening of the compression nuts, and the overall condition of the fittings at that point — this is a spot that, during normal cylinder operation, is usually covered by insulation and is therefore inspected less often than freely accessible piping.
When ordering, it is essential to verify the exact nominal diameter of the connection on your own cylinder — Vaillant offers additional insulation in several sizes (for example also a 2.5-inch version for larger connections), and choosing the wrong size would result either in too loose a fit with gaps, or, conversely, in it being impossible to slide onto the neck at all. If in doubt about the exact connection diameter on a specific cylinder model, we recommend checking the technical documentation of that cylinder or consulting our sales team, who can advise the correct insulation size based on the cylinder's type designation.
Compatibility
This part is intended for connections with a nominal diameter of 2.0 inches, as found on multi-purpose cylinders of the allSTOR exclusiv range and other Vaillant cylinder solutions using the same connection neck size standard. Since Vaillant has modified the design of individual cylinder ranges over time, before ordering we recommend comparing the exact order number or neck diameter with the technical data sheet of your specific cylinder — we are also happy to verify compatibility individually based on the device's type plate.
Maintenance
The connection insulation requires no active maintenance during normal operation. We only recommend an occasional visual check (for example during regular servicing of the cylinder or boiler) to ensure the shell remains properly seated on the neck, and is not mechanically damaged, cracked, or shifted in a way that would expose part of the uninsulated metal. If damage is found (for example material embrittlement after many years of operation, or mechanical damage during other work in the boiler room), it is advisable to simply replace the part with a new one, as it is an inexpensive and readily available item.
Why choose an original Vaillant part
Although the thermal insulation of the connection could in principle be replaced with a universal insulation hose from a general range of products, the original Vaillant part has the advantage of being designed in shape and dimensions specifically for the given cylinder connection neck — thus ensuring a precise fit, an appearance matching that of the cylinder itself, and the use of a material verified by the manufacturer in terms of temperature resistance and fire safety near heat sources. When ordering original parts, you can also be sure that the part fits within the concept of Vaillant's system warranty for the entire installation.
Frequently Asked Questions
Which cylinders is this 2.0" connection insulation intended for?
It is intended for connection necks with a nominal diameter of 2.0 inches, as found on multi-purpose cylinders of the allSTOR exclusiv range and related Vaillant cylinder solutions. We recommend verifying exact compatibility with a specific cylinder model using the technical documentation or by consulting our sales team.
Is it suitable to install this insulation yourself?
Fitting the shell itself is simple, but on an already operating system we recommend entrusting the installation to a qualified plumber, who can also check the tightness and condition of the connection itself underneath the insulation.
Why is insulating connections important if the cylinder is already insulated from the factory?
For design reasons, the cylinder's shell insulation does not cover the connection necks, which therefore remain an uninsulated thermal bridge. Insulating these points reduces overall heat loss and also lowers the risk of surface condensation.
What material is the insulation made of?
It is a shaped shell made of closed-cell foam resistant to elevated temperatures near hot-water piping, designed to meet the usual requirements for use in utility rooms with heat sources.
What is the difference compared to the 2.5-inch version?
The 2.5-inch version is intended for connections with a larger nominal diameter — that is, for different necks or larger cylinder variants with higher flow. It is not interchangeable with the 2.0-inch version, so the size must be selected exactly according to the diameter of the specific connection.
Does the part require any regular maintenance?
No, an occasional visual check during regular cylinder servicing is sufficient — to confirm the shell is still properly seated and not mechanically damaged.
Is a photo of this exact part available?
For small connection parts of this type, a manufacturer photo is not always publicly available in sufficient quality to be clearly matched to a specific order number — if a suitable photo is found, we will add it later.
What warranty applies to this part?
This original Vaillant part comes with the standard statutory 2-year warranty.
When to choose additional insulation instead of replacing the cylinder's entire insulation
When modernizing an older installation, investors sometimes have to decide whether it is more advantageous to address heat loss by completely replacing the cylinder shell with a newer, better-insulated model, or whether targeted addition of the missing insulation at the connection points is sufficient. In many cases, the second route is significantly more economical — if the cylinder shell itself is in good technical condition and its basic insulation meets current standards, but individual connections have, for various reasons (for example the later installation of a solar circuit or heat pump after years of operation), remained without additional insulation, it is enough to order and install just those connection insulation pieces that match the diameter of the given neck. This approach does not require shutting down the entire system for an extended period, is significantly cheaper than replacing the cylinder, and delivers a comparable effect at those specific points where uninsulated heat loss previously occurred.
Thermal bridges in DHW and heating piping — broader context
The topic of thermal bridges at fittings and connections is not specific to a single manufacturer or a single type of cylinder — it is a generally recognized principle in the field of heating technology, which has also found its way into methodologies for assessing the energy performance of buildings. When calculating heat losses in hot water and heating piping, in addition to losses along straight pipe sections, so-called additional losses at fittings, valves, flanges, and connection necks are also taken into account, which can account for an unexpectedly high share of the total loss of the distribution system precisely because these are points with significantly reduced thermal insulation capability compared to a straight pipe section covered with continuous insulation. When designing or modernizing heating systems, attention should therefore be paid not only to the thickness of insulation on straight sections, but also to the completeness of insulation on all fittings, valves, and connections throughout the system.
In practice, this means that even a relatively cheap and simple accessory such as connection insulation can, across all connections on a single cylinder and over its entire service life, deliver measurable savings that pay back several times over its purchase price over the years. That is why Vaillant systematically offers these additional insulation parts as part of its accessories for cylinder solutions, and recommends including them in every new installation of a multi-purpose cylinder, as well as on the list of add-ons when modernizing an older setup where the original connections have not yet been insulated.
For designers and investors dealing with optimizing the operating costs of larger buildings (apartment buildings, facilities with higher hot water consumption, combined sources with a heat pump and solar collectors), thoroughly insulating all connections represents one of the cheapest ways to reduce the overall heat losses of the system without altering its hydraulic concept or control. It is therefore a measure with a very favourable cost-to-benefit ratio, well worth considering for every cylinder installation with multiple connections.
Additional parameters
| Category: | Vaillant – valves, insulation and installation kits |
|---|---|
| Warranty: | 2 years |
| Type: | Thermal connection insulation |
| Nominal connection diameter: | 2.0" |
| Material: | Closed-cell thermal insulation foam |
| Intended for: | allSTOR exclusiv multi-purpose cylinders and compatible Vaillant systems |
| Country of origin: | Germany |
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.