Vaillant high-efficiency electronic class A pump for ecoCRAFT 200/240/280 kW
Code: 0020180028Product detailed description
High-efficiency electronic class A pump for Vaillant ecoCRAFT 200/240/280 kW
This high-efficiency electronic class A boiler circuit pump is original Vaillant accessory intended for stationary condensing boilers of the ecoCRAFT series with the highest output within this range – 200 kW, 240 kW and 280 kW. This represents the highest output segment of the ecoCRAFT series, which as a whole covers an output range from approximately 80 to 280 kW divided into six stages. This segment is installed primarily in boiler rooms of larger residential buildings, administrative and industrial facilities with high heat demand, where it is often combined into a cascade arrangement of multiple units with a total installed output exceeding one megawatt.
The pump ensures forced circulation of heating water through the boiler's primary heat exchanger and its further distribution into the system. It is an electronically commutated type with continuous speed control, which changes directly according to the current burner modulation (ecoCRAFT boilers operate with a modulation range of roughly 17% to 100% of rated output) – at lower current boiler output, the pump automatically reduces its speed and thus also electricity consumption, while at full output (up to 280 kW) it ensures a sufficient, precisely dimensioned flow rate for safe removal of the heat generated in the exchanger.
Technical characteristics
- Application: Vaillant ecoCRAFT (VKK) with output of 200 kW, 240 kW and 280 kW
- Pump type: high-efficiency electronically controlled boiler circuit circulation pump, energy efficiency class A
- Control: continuous speed change according to current boiler burner modulation (modulation range roughly 17–100%)
- Housing material: durable cast iron, circulation part (rotor, bearings) adapted to typical parameters of treated heating water
- Electrical connection: directly from the boiler's control board, without the need for a separate external power source or external speed control
- Max. operating water temperature: up to 110 °C
- Max. system operating pressure: up to 6 bar
- Noise level: low, electronically commutated motor without mechanical brushes
- Installation: directly onto the ecoCRAFT 200/240/280 kW boiler body, according to the manufacturer's installation instructions
- Head/flow rate: the highest parameters within the entire ecoCRAFT pump range, corresponding to the highest output segment of the series
Why this pump is essential for ecoCRAFT 200/240/280 kW boilers
In the highest output segment of the ecoCRAFT series, the demands on pump flow rate and head are the highest within the entire series, which is why Vaillant developed a separate pump design variant with the largest flow cross-section for this segment. Boilers of this output are in practice almost always installed in boiler rooms of larger buildings, very often in a cascade arrangement of multiple units, where it is essential to guarantee a precisely defined and even flow through each individual boiler body. Insufficient flow at this high output would have a particularly significant impact – a larger temperature difference between flow and return (ΔT) at high output means proportionally greater thermal stress on the exchanger and a higher risk of protective boiler shutdown precisely at the moment of highest heat demand.
The electronic interconnection with the boiler's control unit, which adjusts the pump speed directly according to the current burner modulation, is also the reason why it is recommended to use exclusively the original Vaillant pump corresponding to the given output stage for this type of boiler – both the communication protocol and the control curve are set by the manufacturer specifically for this particular component.
Installation and hydraulic connection
Installation must be carried out exclusively by an authorised service technician with professional qualification for the installation of gas and heating equipment, in accordance with the manufacturer's installation instructions. The pump is mounted directly onto the ecoCRAFT 200, 240 or 280 kW boiler body, followed by venting of the circuit and a tightness check at operating pressure. In a cascade arrangement of multiple boilers of this output, the pump of each boiler is set up and tested individually, after which the entire cascade is tested as a functional unit including hydraulic balancing of the individual branches – at such high total cascade outputs, hydraulic balancing is particularly important for even loading of all boilers.
We recommend that the same service order also include a check of heating water quality in accordance with the VDI 2035 guideline, as improperly treated water significantly shortens the service life of both the circulation pump and the boiler's primary exchanger regardless of the quality of the component itself. In practice, installation of this pump is most often carried out during the initial installation of a new ecoCRAFT boiler of this output, when replacing a faulty or worn-out pump, or when expanding an existing large boiler room with an additional boiler in a cascade arrangement.
Compatibility
The pump is intended exclusively for Vaillant ecoCRAFT stationary condensing boilers with output of 200 kW, 240 kW and 280 kW – i.e. the highest output segment of this series. The ecoCRAFT series covers an output range from approximately 80 to 280 kW in six output stages, with Vaillant supplying a separately dimensioned pump with different flow parameters for each segment (80 kW; 120/160 kW; 200/240/280 kW). This component is therefore not interchangeable with pumps intended for lower output segments (80 kW or 120/160 kW), nor with pumps for other Vaillant boiler series. When ordering, we recommend always verifying the exact output designation of the boiler, for example directly on the rating plate.
Maintenance and care
High-efficiency electronic pumps of this type practically require no manual maintenance during normal operation – they have no lubrication points or mechanical components requiring regular lubrication. As part of the annual boiler service inspection, we recommend checking:
- the tightness of the pump connection to the boiler body,
- the noise level and smoothness of pump operation,
- the functionality of the electronic speed control compared to the required boiler modulation,
- the quality of heating water and any deposits in the circulation part during professional disassembly during service.
For large cascade arrangements composed of boilers of this highest output segment, we recommend paying particular attention to regular rotation of load between boilers, as at total outputs exceeding one megawatt, uneven wear of individual pumps has a direct impact on operating costs and the reliability of the entire boiler room.
We therefore also recommend keeping simple service records of individual boilers in the cascade (for example, number of operating hours), which will help identify whether the load is actually being distributed evenly among individual pumps throughout the year.
Why choose an original Vaillant component
The original pump guarantees precise hydraulic and electronic coordination with the ecoCRAFT boiler's control unit, which for boilers of this highest output directly affects the reliability and service life of the entire appliance. The component undergoes the same quality control as the boiler itself, and its use is also a condition for the manufacturer's warranty on the boiler body to be honoured in the event of a fault related to heating water circulation. Given the extremely high value of the investment in a boiler room with boilers of this output (often in a cascade arrangement of multiple units), the use of a non-original or incorrectly dimensioned pump is clearly not recommended.
In projects of this scale, the price difference between an original and an unverified component becomes negligible compared to the risk of failure or damage to a high-value boiler.
About the Vaillant ecoCRAFT series and the role of the highest 200/240/280 kW segment
ecoCRAFT exclusiv (VKK) is a series of stationary (floor-standing) Vaillant gas condensing boilers intended for commercial, industrial and larger residential applications, with an output range of approximately 80 to 280 kW divided into six output stages. The 200/240/280 kW segment represents the top of this series and is chosen where the highest capacity of a single boiler body is required – for example in large residential buildings, shopping centres, industrial halls or other facilities with high and stable heat demand. It is precisely in this segment that a cascade arrangement of multiple boilers is most often encountered, where the total installed output can reach up to several megawatts.
Vaillant supplies three separately dimensioned variants of this pump for the ecoCRAFT series according to the boiler's output segment – for 80 kW, for 120/160 kW and for 200/240/280 kW (this component, with the highest flow parameters within the entire series). When ordering a cascade arrangement combining boilers of different output stages, it is therefore necessary to order a pump corresponding to each boiler's specific output segment, not a single universal component for the entire cascade.
Frequently asked questions
Is this pump included in the standard delivery of the ecoCRAFT 200/240/280 kW boiler?
For ecoCRAFT boilers, this pump is a standard required accessory that is ordered separately from the boiler body, as the manufacturer does not supply it as a fixed part of the boiler's basic package.
Is this pump the same for the 200, 240 and 280 kW models?
Yes, Vaillant supplies the same pump component for these three highest output stages of the ecoCRAFT series, as they fall within the same design segment with the highest flow requirements within the series.
Can this pump also be used with lower ecoCRAFT segments?
No, for the 80 kW and 120/160 kW segments, Vaillant supplies separately dimensioned, smaller pump variants with lower flow parameters that are not interchangeable with this component.
Does this pump save electricity even at such a high output?
Yes, the electronically controlled class A pump continuously adjusts its speed according to the current boiler modulation even in this highest output segment, bringing significant electricity savings during year-round operation of a large boiler room compared to an older, non-regulated pump.
Can the pump be installed by an ordinary home handyman?
No. Installation requires professional qualification for working with gas and pressurised heating equipment and intervention in the boiler's primary circuit, and may therefore only be carried out by an authorised service technician with the relevant qualification for boilers of this output.
Is the pump suitable for a large cascade arrangement of multiple ecoCRAFT boilers?
Yes, it is precisely in large cascade arrangements of boilers of this highest output that ensuring correct flow through each individual boiler is particularly important, and this pump fitted to each boiler body is the standard solution to this requirement.
What is the warranty on this component?
Original Vaillant accessories carry a standard warranty of 24 months from the date of sale or commissioning by an authorised service technician.
Why does the boiler report a flow fault even after replacing the pump?
The most common causes are air in the system, insufficiently open shut-off valves in the boiler circuit, or a clogged filter on the return pipe. For large systems, we recommend having the flow fault investigated by a service technician, including a check of the hydraulic balance of the entire cascade.
How do I determine the exact output segment of my ecoCRAFT boiler?
The exact output designation can be found on the boiler body's rating plate, or in the accompanying technical documentation or installation record. If in doubt, we recommend contacting an authorised Vaillant service centre.
Does this pump also require separate thermal insulation?
For its highest-output boilers, Vaillant offers separate thermal insulation components for pumps and connection fittings, which reduce heat losses in a large boiler room. We recommend checking the suitability and availability of specific insulation for this output segment with an authorised service centre or supplier.
Does the failure of one pump in a cascade affect the operation of the entire boiler room?
In a correctly designed cascade, the failure of one boiler's pump generally does not jeopardise the operation of the entire boiler room, as the control system can temporarily redistribute the load to the other functional boilers. However, the affected boiler's downtime should be resolved as soon as possible to restore the full capacity of the boiler room, especially during periods of high heat demand.
Additional parameters
| Category: | Vaillant – valves, insulation and installation kits |
|---|---|
| Warranty: | 2 years |
| Brand: | Vaillant |
| Product type: | High-efficiency electronic boiler circuit pump |
| Application: | Vaillant ecoCRAFT (VKK) with output of 200 kW, 240 kW and 280 kW |
| Energy efficiency class: | A (in accordance with ErP Regulation 641/2009) |
| Speed control: | Continuous, electronic, according to current boiler modulation |
| Pump housing material: | Cast iron, circulation part resistant to treated heating water |
| Electrical connection: | Directly from the boiler's control board, without a separate external power source |
| Max. operating temperature: | up to 110 °C |
| Max. operating pressure: | up to 6 bar |
| Country of origin: | Germany / EU (Vaillant Group) |
| Warranty: | 24 months |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.