Vaillant hydraulic connection set boiler – cylinder VIH R 150, with safety group, temperature sensor and siphon

Code: 0020151262
Not rated Rating details
260 € –5 %
vaillant 0020151261 kit connessione murali unistor 120
260 € –5 % 247 € / pcs Measure price:
In stock at supplier

Detailed information

Product detailed description

Vaillant hydraulic connection set between the boiler and the VIH R 150 cylinder, with safety group, temperature sensor and siphon

This Vaillant hydraulic connection set is designed for the complete connection of the wall-mounted ecoTEC plus condensing boiler with the larger external VIH R 150 domestic hot water storage cylinder (150-litre volume). It is a set designed and tested by the manufacturer as a single unit, offering all the necessary parts precisely matched to each other – hydraulic piping, safety group, temperature sensor and siphon – instead of assembling them from separate individual components. This simplifies and speeds up installation for the installation company and at the same time eliminates the risk of an incorrect combination of parameters.

Why choose the 150-litre volume

The VIH R 150 cylinder with a volume of 150 litres is a suitable choice for households with a higher number of occupants (typically four or more people), for houses with two bathrooms, or where there is a common simultaneous need for hot water at multiple draw-off points at once. Compared to the smaller 120-litre cylinder, it provides a greater reserve of hot water for the morning or evening consumption peak, reducing the risk that the hot water supply will run out before the boiler manages to reheat it when several household members shower at the same time. This reserve is especially advantageous in households with irregular, burst-type consumption (for example a larger family with children, or a household that often has guests).

Contents of the set

The set includes hydraulic connecting piping between the boiler outlets and the corresponding connections of the VIH R 150 cylinder, a safety group matching the operating pressure of this specific cylinder, a cylinder water temperature sensor for communication with the boiler control, and a siphon for the safe and hygienic discharge of water from the safety valve, as well as condensate, into the sewage system. Due to the larger cylinder volume, the connecting piping and safety group themselves are also dimensioned with regard to this larger volume of water in the system.

Reheating control thanks to the temperature sensor

The temperature sensor fitted in the cylinder's immersion sleeve provides the boiler control with information about the current water temperature, based on which the boiler decides on starting and the intensity of reheating the cylinder. With the larger 150-litre cylinder volume, the correct function of this sensor is even more important for operating efficiency – with a larger volume of water, reheating takes longer, so it is important that the control has accurate and timely information about the temperature drop and can start reheating at the optimal time – neither too late (risk of insufficient hot water) nor unnecessarily often (unnecessary energy consumption).

Safety group adapted to the larger volume

The safety group included in this set protects the VIH R 150 cylinder against a dangerous increase in pressure during water heating. With a larger cylinder volume, this protection is even more important, since in the event of a fault there is a risk of a larger volume of hot water being released than with a smaller cylinder – which is precisely why it is essential that the discharge piping from the safety valve (handled in this set via the siphon) is sufficiently dimensioned and correctly routed to a safe discharge point.

Siphon and condensate discharge

The siphon in this set ensures the safe discharge of water from the safety valve as well as the acidic condensate from the condensing boiler into the sewage system, while its water seal prevents sewage odours from penetrating back into the installation area. Correct function of the siphon is a prerequisite for hygienic and trouble-free operation of the whole assembly, so its patency should be part of the regular inspection during service visits.

Installation

Installation of this connection set is part of the overall installation of the boiler + cylinder assembly and should take place simultaneously with the installation of the boiler and cylinder, exclusively by a qualified installer authorised to install gas and pressure equipment. It is important to correctly mechanically connect the piping, correctly fit the temperature sensor into the cylinder's immersion sleeve with good thermal contact, and correctly route the discharge via the siphon into the sewage system with sufficient gradient, taking into account the larger possible volume of discharged water with the larger cylinder.

Compatibility

This connection set is designed specifically for the combination of Vaillant ecoTEC plus boilers with the VIH R 150 cylinder – i.e. for the 150-litre volume. For a smaller cylinder (for example VIH R 120), the corresponding separate variant of the set must be chosen, as the connection dimensions and safety group sizing differ between the individual cylinder volumes. Before ordering, we recommend verifying the exact model of the cylinder and boiler in your installation.

Why choose the original connection set

The original Vaillant connection set guarantees that all components (piping, safety group, sensor, siphon) are designed and tested as a functional unit specifically for the combination of the boiler and the 150-litre cylinder. Alternatively assembling it from individually procured parts would carry the risk of an incorrect combination of parameters – for example an unsuitably dimensioned safety group with regard to the larger cylinder volume, or an incompatible type of temperature sensor.

Maintenance

As part of the regular annual service inspection, we recommend checking the functionality of the safety valve (using the test lever), the patency of the siphon and discharge, and the correct fitting of the temperature sensor. With a larger cylinder volume, it is advisable to pay increased attention to the overall condition of the cylinder's thermal insulation, since a larger volume of water also means a greater potential for heat loss during longer periods between individual draw-offs if the cylinder insulation is not in good condition.

Frequently Asked Questions

Who is the 150-litre cylinder more suitable for compared to the 120-litre one?

The 150-litre cylinder is more suitable for households with four or more people, with two bathrooms, or with a common simultaneous need for hot water at multiple points, as it provides a greater reserve for peak consumption.

What does this connection set include?

The set includes hydraulic connecting piping between the boiler and the VIH R 150 cylinder, a safety group, a cylinder water temperature sensor, and a siphon for discharging water from the safety valve and condensate.

Is this set interchangeable with the set for the VIH R 120 cylinder?

No, each cylinder volume has its own separately dimensioned variant of the connection set. Before ordering, it is necessary to verify the exact volume of the cylinder in your installation.

Who is allowed to install the set?

Installation should be carried out exclusively by a qualified installer authorised to install gas and pressure equipment, simultaneously with the installation of the boiler and cylinder.

What warranty applies to this set?

For this original Vaillant part, we provide the standard statutory warranty of 2 years.

Wider context – planning hot water capacity for a larger household

When designing a suitable hot water cylinder capacity, it is advisable to base the decision not only on the number of household occupants, but also on the actual consumption pattern – i.e. whether there is simultaneous draw-off at multiple points (for example two bathrooms used at the same time), or whether consumption is spread gradually throughout the day. The 150-litre cylinder combined with the powerful ecoTEC plus condensing boiler represents a balanced choice for most larger family homes without the need to switch to a significantly larger (and more expensive, more space-demanding) stationary cylinder.

When ordering this connection set, we also recommend considering additional accessories depending on your space layout – for example an aesthetic insulating cover for concealed placement of the cylinder under the boiler, or additional soundproofing insulation when installing near living spaces. Our team will be happy to help you put together a complete solution tailored exactly to your project.

Space requirements of the larger cylinder

The 150-litre cylinder naturally has larger external dimensions than the smaller 120-litre variant, which needs to be taken into account already at the design stage of the utility room or space where the boiler + cylinder assembly is to be located. When installing under the boiler, sufficient clear height of the space must be allowed for; when installing next to the boiler, sufficient wall width is needed. This connection set is dimensioned precisely for the dimensions and connections of the VIH R 150 cylinder, so when using it there is no need to resolve any additional reductions or piping modifications beyond standard installation.

Effect of larger volume on reheating dynamics

With a larger cylinder volume, its complete reheating from a cooled-down state to operating temperature naturally takes longer than with a smaller cylinder, even if the same boiler were used. In normal operation, however, this is not a disadvantage – the boiler control keeps the cylinder continuously topped up to the set temperature, and complete cooling down only occurs exceptionally (for example after a longer absence with the heating switched off). This is precisely why the reliable function of the temperature sensor included in this set is important – it ensures that the boiler regularly, at optimal intervals, replenishes the energy consumed, instead of letting the cylinder cool down and then having to perform a significantly longer complete reheating.

Frequently Asked Questions – supplement

Does reheating the 150-litre cylinder take significantly longer than the 120-litre one?

Complete reheating from a cooled-down state takes somewhat longer, but in normal operation the control continuously keeps the cylinder topped up, so this difference is minimal in practice.

Does the larger cylinder require more installation space?

Yes, the 150-litre cylinder has larger external dimensions than the 120-litre variant, which needs to be taken into account when designing the utility room space or when installing under the boiler.

Is this set compatible with all Vaillant controllers?

The temperature sensor in this set is designed for communication with the control system of fifth-generation ecoTEC plus boilers and common Vaillant controllers communicating via the eBUS bus. If you are unsure about compatibility with a specific controller, please contact us.

Choosing between 120 and 150 litres – summary of decision criteria

When deciding between the 120 and 150-litre volume, we recommend considering primarily the number of people in the household, the number of bathrooms, and the likelihood of simultaneous hot water draw-off at multiple points. As a rough guideline, households of up to three people with one bathroom will in most cases be well served by the smaller 120-litre volume, while households with four or more people, or with two fully used bathrooms, will appreciate the reserve provided by the 150-litre volume. The chosen cylinder volume should also be matched to the output of the boiler that reheats the cylinder – when combined with a more powerful boiler (for example the 25CS or 35CS range), reheating of the larger cylinder is faster than when combined with the smallest 10CS model.

If you are unsure about the right choice for your specific case, do not hesitate to contact our team – we will be happy to discuss the actual hot water consumption pattern in your household with you and recommend the optimal combination of boiler, cylinder and this connection set.

Summary of the benefits of the original solution

This connection set simplifies the realisation of the boiler + VIH R 150 cylinder assembly into a single comprehensive, manufacturer-verified package, saving the installation company time spent sourcing and verifying the compatibility of individual separate components. For the end customer, this means faster and more reliable project realisation, assurance of correctly functioning communication between the cylinder and the boiler control, and, not least, clear warranty responsibility in the event of any claim related to this part of the installation.

We recommend ordering this set together with the boiler and the VIH R 150 cylinder in a single delivery, so that the installation company has all the necessary parts available at once and can plan the complete installation in a single work session without unnecessary waiting for additionally purchased components. For larger projects involving a complete replacement of the heat source including modification of the distribution system, it is advisable to align the delivery of this set with the overall schedule of construction and installation works.

If you are replacing an older boiler + cylinder assembly with a new ecoTEC plus system with VIH R 150, we also recommend checking the condition of the original piping routing and possibly considering its partial modification, as older installations may not have included all the elements that this modern set addresses in one unit (for example a separate siphon for condensate discharge from the condensing boiler, which older non-condensing boilers did not need). Our technical advisors will be happy to help you assess whether this standard set fully covers your specific situation, or whether it is advisable to supplement it with additional components tailored to your project.

If you are planning a complete renovation of the utility room together with the replacement of the heat source, we also recommend taking into account, when designing the layout, the space needed for future access to the safety group (for regular testing), to the temperature sensor (for possible future replacement), and to the siphon (for checking patency). A well-designed utility room layout facilitates not only the initial installation but also all future service work throughout the entire service life of the assembly, which ultimately also results in lower costs and shorter time for each future service intervention.

Additional parameters

Category: Vaillant – valves, insulation and installation kits
Warranty: 2 years
Brand: Vaillant
Type: Hydraulic connection set boiler – cylinder
Designed for cylinder: VIH R 150 (150 l)
Components: connecting piping, safety group, temperature sensor, siphon
Compatibility: Vaillant ecoTEC plus boilers
Sensor function: communicating cylinder temperature with boiler control
Discharge: siphon for safety valve and condensate
Installation: qualified installer only
Country of origin: Germany
Warranty: 2 years

Product rating

Be the first who will post an article to this item!

Do not fill out this field:

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field:

O spoločnosti

Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.

Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.

Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.

Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.

Udržateľnosť 

Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.

Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.

 

Vytvořil Shoptet | Design Shoptak.cz. > >