Vaillant VDM 10 direct pump group – a complete solution for a direct heating circuit
Vaillant VDM 10 direct (order number 0020191817) is an original, highly efficient pump group designed for a direct (unmixed) heating circuit that operates at the same temperature level as the boiler outlet. This is a typical case of a radiator circuit that complements a lower-temperature underfloor heating circuit connected via a VDM 20 M or VDM 25 M mixing group – together they form a classic solution for a dual-circuit (or multi-circuit) heating system built around Vaillant ecoTEC plus, ecoTEC pro or ecoTEC exclusive condensing boilers. The group is mounted on a manifold or hydraulic separator (low-loss header) with a 120 mm mounting distance, which is the standard used by most professional quick-installation systems on both the Slovak and Czech markets.
What exactly is included in the VDM 10 direct package
- High-efficiency electronic circulation pump, energy efficiency class A (wet-rotor design, with automatic speed control according to the current demand of the circuit, saving electricity compared to older three-speed pumps)
- 230 V power supply, standard household wiring, no special installation required
- Two round thermometers (on the supply and return lines), giving the technician and homeowner an instant visual overview of the circuit temperature without the need for a meter or app
- Complete thermal insulation made of shaped EPP (expanded polypropylene), which significantly reduces heat losses from the pump group into the boiler room or utility room and also prevents condensation on cooler pipe sections
- Shut-off ball valves on both sides of the group for easy service shutdown without draining the entire system
- 120 mm mounting distance compatible with all WHV series manifolds and standalone WH series low-loss headers
How a direct circuit works and why you need it
In a modern family house or a larger facility, it is increasingly common to combine several heating branches with different temperature requirements. Radiators typically operate with a temperature gradient of around 55/45 °C or even higher, while underfloor heating requires a substantially lower water temperature, typically 35–40 °C. If both circuits were connected directly to the boiler outlet without regulation, the underfloor heating would receive water that is too hot, which is not only energy-inefficient but for some types of flooring (wood, laminate) can also damage the covering or exceed the surface temperature limit. The solution is to split the system into separate circuits: the circuit that has the same temperature as the boiler (e.g. radiators) is connected via a direct pump group VDM 10 – this simply ensures water circulation in that circuit without any temperature change. The lower-temperature circuit (underfloor heating) is connected via a VDM 20 M or VDM 25 M mixing group, which uses a three-way valve to blend cooler return water with the boiler outlet, thus regulating the temperature to the required level.
VDM 10 direct is therefore not "just a circulation pump" – it is a complete, technically sophisticated and aesthetically unified module that simplifies installation, shortens installation time, and ensures that all components (pump, thermometers, insulation, shut-off valves) come from a single manufacturer and are mutually tuned in terms of pressure losses and hydraulic characteristics.
When to choose VDM 10 direct instead of a mixing group
Choose the direct group whenever the given heating circuit does not need temperature regulation independent of the boiler – that is, when the temperature supplied by the boiler (possibly regulated only via weather-compensated control of the boiler itself) is sufficient. Typical applications:
- Radiator circuit in a family house, where the second circuit is underfloor heating in the bathroom or living room
- Pool heating circuit via a heat exchanger, where three-way mixing regulation is not necessary (regulation is handled differently, e.g. thermostatically at the exchanger)
- The first (highest-temperature) circuit in a multi-circuit system with several temperature levels, from which heat is gradually drawn off for lower-temperature branches through further mixing groups
- Auxiliary heating circuit for ventilation equipment or an air heating coil, where the required temperature is the same as or close to the temperature of the boiler circuit
Assembly and installation – what a technician should know
The VDM 10 pump group is connected to a Vaillant WHV or WH series manifold or hydraulic separator (low-loss header) using a screw connection with a 120 mm mounting distance. Before installation, we recommend checking:
- Flow direction – the arrow on the pump body must match the actual direction of water flow in the circuit
- Venting – both the pump and the entire circuit must be thoroughly vented on first start-up, ideally using an automatic air vent at the highest point of the circuit
- Pump settings – the class A electronic pump allows selection of an operating mode (constant pressure, proportional pressure, constant speed) depending on the nature of the circuit; for a radiator circuit with thermostatic heads, proportional pressure mode is generally recommended, as it reduces noise when the valves are partially closed
- Electrical connection – the pump is powered by 230 V; control of operation (switching on/off according to heat demand) is usually taken over by the boiler controller or a room/weather-compensated controller via a relay or potential-free contact
- Insulation parts – once wiring is complete, both EPP insulation pieces are fitted so that they cover the entire body of the group, including the fittings, minimizing heat losses
The group is designed as a plug-and-play module – all components (pump, thermometers, ball valves) are already factory-assembled on a common body, so on site it is only necessary to connect the supply and return piping and the pump's power supply.
Compatibility
VDM 10 direct is designed for installation together with Vaillant ecoTEC plus, ecoTEC pro and ecoTEC exclusive condensing boilers (including newer models with IoniDetect technology), via Vaillant WHV series manifolds (e.g. WHV 35) or WH series hydraulic separators (WH 27, WH 40, WH 95, WH 160). The 120 mm mounting distance is consistent across the entire Vaillant range of pump groups and manifolds, so the group can be combined with other direct and mixing groups into multi-circuit assemblies. The group can also be used as a standalone replacement in a functioning system that already uses a compatible low-loss header or manifold from another brand with the same mounting distance – in that case we recommend verifying connection compatibility with a technician.
Maintenance and service
The VDM 10 pump group does not require any special regular maintenance beyond normal care of the heating system. We recommend:
- Once a year (ideally before the heating season), check that the pump rotates freely, and if there has been a long summer shutdown, run it briefly to prevent the rotor from getting stuck due to deposits
- Monitor the readings on the round thermometers – a significant difference between the supply and return temperature outside the normal range may indicate a flow problem or a clogged circuit
- Check the tightness of the screw connections, especially after the first heating cycle, when thermal expansion of the material occurs
- If the system pressure drops, top up water according to the boiler manufacturer's instructions, and in the case of hard water, consider installing a softening cartridge, which extends the life of both the pump and the boiler's heat exchanger
- In the event of unusual pump noise (buzzing, knocking), check the venting of the circuit and the pump's operating mode setting
With proper maintenance and good heating water quality, the service life of class A wet-rotor circulation pumps typically ranges from 10 to 15 years, while the pump group body and insulation itself will last practically for the entire lifetime of the heating system.
Why choose this particular pump group
Choosing original accessories from the boiler manufacturer brings several advantages over generic solutions assembled from components of various brands. First, guaranteed hydraulic and mounting compatibility – the 120 mm distance, connection diameters and pressure losses are all tuned precisely to work with Vaillant boilers and manifolds. Second, a unified installation appearance – the white body and insulation match the design of ecoTEC boilers, which is especially appreciated by customers with a visible boiler room or utility room within the living area of the house. Third, easier future servicing – an authorized Vaillant service technician has immediate access to original spare parts and technical documentation for original components, which is not always guaranteed with non-original solutions. Finally, the class A electronic pump represents real savings in electricity consumption compared to older unregulated circulation pumps, which shows up on the electricity bill over year-round operation.
Energy class A of circulation pumps – why it matters
European legislation (the ErP Directive, Regulation 641/2009) has gradually pushed older unregulated three-speed circulation pumps out of the market in favor of electronically controlled units with high energy efficiency (EEI index below 0.20 for class A). The difference in consumption is particularly noticeable during year-round operation: while an older pump ran at practically constant speed throughout the entire heating season regardless of actual heat demand, the electronically controlled pump in the VDM 10 continuously adapts its output to the current state of the circuit – when thermostatic heads on the radiators partially or fully close the flow, the pump reduces its speed and consumption instead of increasing pressure against closed valves (which would cause noise and unnecessary wear). In an average family house, this saving amounts to tens of kWh of electricity per year on just one circulation pump, which multiplies in a multi-circuit system with two or three pump groups.
Common mistakes in designing and installing a multi-circuit system
When implementing multi-circuit heating systems, we repeatedly encounter several mistakes that can be avoided by correctly selecting and connecting components:
- Confusing a direct group with a mixing group – installing a direct VDM 10 group on a circuit that actually needs temperature regulation (typically underfloor heating) leads to overheating of the floor and unnecessary heat losses.
- Lack of hydraulic separation – connecting several pump groups directly to the boiler without a manifold or low-loss header can cause the circuits to mutually interfere hydraulically and lead to unstable temperature control.
- Underestimating sizing – when designing the system, the total flow of all connected circuits must be compared with the capacity of the chosen manifold or low-loss header (e.g. WHV 35 or WH 40) to avoid excessive pressure losses.
- Insufficient venting – pump groups with electronic pumps are sensitive to air in the system, which causes noise and reduces heat transfer efficiency; thorough venting during commissioning is therefore essential.
- Neglecting insulation losses – improperly fitted or damaged insulation increases heat losses in the utility room, which in summer can also cause unwanted overheating of the space.
Comparison with other pump groups in the VDM range
In addition to the direct VDM 10 group, atria.sk also offers the mixing variants VDM 20 M (three-way valve Rp 3/4˝, Kv 6.3) and VDM 25 M (three-way valve Rp 1˝, Kv 8.0), which differ mainly in connection size and flow capacity of the mixing valve – the VDM 25 M is more suitable for circuits with higher required flow, for example larger underfloor heating installations or several heating zones connected via a common manifold. For a complete turnkey dual-circuit solution, we also offer ready-made VDM sets (a combination of a manifold with a low-loss header and two pump groups), which are more cost-effective than buying individual components separately and also guarantee mutual compatibility of all parts.
Frequently asked questions
- Can I use VDM 10 direct for underfloor heating as well? This is not a recommended solution – the direct group has no built-in temperature regulation, so it would supply the underfloor circuit with water as hot as the boiler circuit temperature, which can damage the floor covering and is energy-inefficient. For underfloor heating, use a VDM 20 M or VDM 25 M mixing group.
- Is a separate controller needed to control the pump? Switching the pump on and off is handled by the boiler controller or a connected room/weather-compensated controller. The pump itself internally handles speed regulation according to the selected operating mode (constant or proportional pressure).
- What is the difference between VDM 10 and older unregulated pump groups? VDM 10 uses an electronically controlled class A circulation pump, which automatically adapts its speed to the current demand of the circuit, saving electricity and reducing noise compared to older-generation three-speed pumps.
- Can VDM 10 direct be mounted on a manifold other than Vaillant WHV or WH? If the manifold or low-loss header has the same 120 mm mounting distance and a compatible screw connection, this is technically possible. However, we recommend verifying compatibility with a technician before purchase to avoid complications during installation.
- Do I need to order a separate manifold or low-loss header for installing this group? Yes, VDM 10 direct is a standalone pump group without its own manifold – for a multi-circuit system you also need a dual-circuit (or multi-circuit) manifold, such as the WHV 35, or a combined set that already includes both the manifold and the pump groups in one package.
- What is the warranty on this product? We provide a standard statutory warranty of 2 years from the date of sale on the VDM 10 direct pump group.
Additional parameters
| Category: | Vaillant – pump groups and accessories |
|---|---|
| Warranty: | 2 years |
| Product type: | Direct pump group |
| Pump efficiency class: | A (electronically controlled) |
| Power supply: | 230 V |
| Temperature regulation: | none (direct circuit) |
| Mounting distance: | 120 mm |
| Equipment: | 2× round thermometer, thermal insulation, ball valves |
| Brand: | Vaillant |
| Country of origin: | Germany |
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.