Vaillant high-efficiency pump with connection for ecoTEC plus 80, 100 and 120 kW
Code: 0020217872Product detailed description
High-efficiency pump with connection for Vaillant ecoTEC plus 80, 100 and 120 kW
This part is an original assembly of a high-efficiency circulation pump together with a connection fitting, designed specifically for Vaillant ecoTEC plus wall-hung condensing boilers in the highest power range – namely for models VU 806/5-5 (16.5 – 82.3 kW), VU 1006/5-5 (20.7 – 102.8 kW) and VU 1206/5-5 (24.7 – 123.4 kW at a temperature drop of 50/30 °C). These boilers are used mainly in larger residential buildings, administrative and operational buildings, industrial halls and cascade boiler rooms, where a high and reliably controllable heat output is required. The pump is a key hydraulic component of the boiler circuit – it ensures forced circulation of heating water through the boiler's heat exchanger and its subsequent distribution to the system, while the connection fitting handles the mechanical and hydraulic connection of the pump to the boiler body.
For boilers with an output of 80 to 120 kW, the volume of water flow and the demands on the pump's head are considerably higher than for common domestic boilers up to 35 kW, which is why Vaillant has developed a separate design series of pumps for this power segment with a larger flow cross-section and a reinforced connection fitting. Using a non-original or undersized pump in this segment can lead to insufficient circulation, boiler fault messages (for example due to overheating of the primary heat exchanger) or increased wear of the circulation mechanism.
Technical characteristics
- Intended for: Vaillant ecoTEC plus VU 806/5-5, VU 1006/5-5 and VU 1206/5-5 (80, 100 and 120 kW)
- Pump type: high-efficiency electronically controlled circulation pump, energy efficiency class A
- Control: continuous speed variation according to the current burner modulation and the set control mode (e.g. Δp-c or Δp-v depending on the boiler's control electronics design)
- Connection fitting: included in the delivery is a connection fitting that mechanically and hydraulically connects the pump to the heating outlet of the boiler body
- Material: pump body made of durable cast iron, circulation part (rotor, bearings) made of materials resistant to water treated according to VDI 2035 guidelines
- Electrical connection: power supply and control directly from the boiler control board (no separate external power source required)
- Max. operating water temperature: up to 110 °C
- Max. system operating pressure: up to 6 bar
- Noise level: low, electronically commutated motor without mechanical brushes
- Installation: directly on the boiler body, usually at the bottom or rear of the boiler depending on the specific model
Why this pump is essential for 80 – 120 kW boilers
ecoTEC plus boilers in the 80 to 120 kW power range are almost always connected either individually into a larger heating system with multiple heating branches, or in a cascade arrangement of up to six boilers with a total output of up to 720 kW. In both cases, sufficient and even flow through each individual boiler must be guaranteed – insufficient flow leads to a larger temperature difference between flow and return (ΔT), which increases the thermal stress on the heat exchanger and can trigger a protective boiler shutdown. This is precisely why the manufacturer supplies this pump as a separate, precisely sized part for each power stage (80, 100 and 120 kW), rather than as a universal part common to the whole range.
The pump also works directly with the boiler's control electronics – its speed changes depending on the current burner modulation, achieving an optimal ratio between the pump's electricity consumption and the thermal efficiency of the entire system. This electronic interconnection is the reason why it is recommended to use exclusively the original Vaillant pump corresponding to the given power stage for this type of boiler, since the communication protocol and control curve are set by the manufacturer specifically for this part.
Installation and hydraulic connection
Installation must be carried out exclusively by an authorised service technician with professional qualification for installing gas and heating equipment. The pump is mounted directly onto the boiler body using the supplied connection fitting, which also ensures the tightness of the joint with the rest of the heating circuit. Before installation, the system must be drained or at least depressurised in the given branch; after installation, the circuit must be vented and checked for tightness at operating pressure. In a cascade arrangement of multiple boilers, the pump of each boiler is set and tested individually, and the entire cascade is then tested as a functional unit, including hydraulic balancing of the individual branches.
We recommend that the same service order also include a check of the heating water quality (especially hardness and oxygen content) according to VDI 2035 guidelines, since improperly treated water significantly shortens the service life of both the circulation pump and the boiler's primary heat exchanger, regardless of the quality of the part itself.
In practice, this pump is most commonly installed on these occasions: during the first installation of a new ecoTEC plus boiler in the given power range, when replacing a faulty or worn-out original pump after several years of operation, or when expanding an existing boiler room with an additional boiler in a cascade arrangement. In all three cases, the same principle applies – the part must precisely match the power stage of the specific boiler body.
Compatibility
The pump with connection is intended exclusively for Vaillant ecoTEC plus wall-hung condensing boilers in the 80 – 120 kW power range, specifically models VU 806/5-5, VU 1006/5-5 and VU 1206/5-5, which are commonly installed individually, in tandem, or in a cascade of up to six units with a total output of up to 720 kW. Due to the different flow requirements of the individual power stages, this part is not interchangeable with pumps intended for lower power ranges (e.g. 48 – 65 kW), for which Vaillant supplies a separate, smaller pump type. When ordering, we always recommend verifying the exact power designation of the boiler (e.g. directly on the rating plate) to ensure correct compatibility.
Maintenance and care
High-efficiency electronic pumps of this type practically require no manual maintenance during normal operation – they have no lubrication points or mechanical components requiring regular lubrication. However, as part of the annual boiler service inspection, it is recommended to check:
- the tightness of the connection fitting and any traces of deposits at the joint,
- the noise level and smoothness of the pump's operation (unusual sounds may indicate air in the system or mechanical wear),
- the functionality of the electronic speed control in comparison with the required boiler modulation,
- the quality of the heating water and any deposits in the circulation part during professional disassembly during service.
During a prolonged system shutdown (for example outside the heating season in combined industrial applications), we recommend running the pump briefly at least once every few weeks to prevent the rotor from seizing due to deposits – in newer electronic pumps, this function is often automatically taken over by the boiler's control unit (so-called anti-blocking run).
Why choose an original Vaillant part
The original pump with connection guarantees precise hydraulic and electronic coordination with the boiler's control unit, which for boilers of this power directly affects the reliability and service life of the entire system. The part undergoes the same quality control as the boiler itself, and its use is also a condition for the manufacturer's warranty on the boiler body to be honoured in the event of a fault related to the circulation of heating water. Given the high value of the investment in a boiler of this power segment, the use of a non-original or incorrectly sized pump is clearly not recommended.
Overview of ecoTEC plus 80 – 120 kW power models
The following table serves as a guide when selecting the correct power stage of the boiler and the associated pump. Exact values for a specific boiler can always be found on its rating plate or in the technical documentation supplied by the manufacturer.
- VU 806/5-5: rated heat output at 50/30 °C approximately 16.5 – 82.3 kW, at 80/60 °C approximately 14.9 – 74.7 kW, boiler body weight approx. 68 kg
- VU 1006/5-5: rated heat output at 50/30 °C approximately 20.7 – 102.8 kW, at 80/60 °C approximately 18.7 – 93.3 kW, boiler body weight approx. 86 kg
- VU 1206/5-5: rated heat output at 50/30 °C approximately 24.7 – 123.4 kW, at 80/60 °C approximately 22.4 – 112.0 kW, boiler body weight approx. 90 kg
- All three models achieve a standardised utilisation rate of up to around 109% at partial load (30%), the burner modulation range is 20 – 100% of rated output
- The boilers can be connected in a cascade of up to six units with a total installed output of up to 720 kW – in such a case, a pump is fitted separately on each boiler in the cascade
Ordering and part identification
When ordering this pump, it is essential to know the exact type and power designation of the boiler to which it is to be installed – i.e. whether it is model 806, 1006 or 1206. This information can be found on the rating plate of the boiler body, usually on the inside of the front cover, or in the accompanying technical documentation or the installation report handed over to the investor upon completion of the work. In case of uncertainty, we recommend contacting an authorised Vaillant service or the heating supplier who carried out the installation, in order to avoid ordering the wrong variant and unnecessarily extending the service intervention.
The part is supplied as a complete installation kit, including seals and mounting material, so no additional small components need to be purchased for installation on the boiler body itself. The electrical connection to the boiler's control board is handled via a connector corresponding to the given boiler range, so the qualified technician can make the connection without any wiring modifications.
Frequently asked questions
Is this pump included with the boiler, or must it be ordered separately?
For ecoTEC plus boilers in the 80 – 120 kW power range, this pump is a standard required accessory that is ordered separately alongside the boiler body, as the manufacturer does not supply it as a fixed part of the boiler's basic package.
Can one pump be used for all three power models (806, 1006, 1206)?
No, this part is designed jointly for the entire 80-120 kW range, but it is always necessary to verify the exact power designation of the specific boiler when ordering, so that the selected pump matches its flow requirements and connection dimensions.
Is separate insulation also needed for this pump?
Vaillant offers a separate part for boilers of this power range – thermal insulation for the pump with connection – which reduces heat losses in the boiler room and is recommended especially for installations with long pump run-on outside the heating season.
Can the pump be installed by an ordinary DIY handyman?
No. Installation requires professional qualification for working with gas and pressurised heating equipment, intervention in the boiler's primary circuit, and setting of the pump's control curve in conjunction with the boiler's control electronics.
What is the warranty on this part?
Original Vaillant accessories are covered by a standard 24-month warranty from the date of sale, or commissioning by an authorised service technician.
Why does the boiler report a flow fault even after replacing the pump?
The most common cause is air in the system, insufficiently opened shut-off valves on the boiler circuit, or a clogged filter on the return pipe. In case of a flow fault, we recommend having the system checked by a service technician, including venting and checking the filters for clogging.
Does this pump save electricity compared to older types?
Yes. The electronically controlled class A pump continuously adjusts its speed according to the current demand of the system instead of running at constant speed, which brings noticeable electricity savings compared to older, non-regulated pumps in installations with a long annual boiler room operating time.
Is the pump noisy and will its operation be audible in the boiler room?
The electronically commutated motor without mechanical brushes operates with significantly lower noise than older pump types. In a standard boiler room with adequate sound insulation, the pump's operation is not disruptive; for more sensitive spaces (e.g. a boiler room adjacent to living rooms), we recommend also adding thermal and acoustic insulation to the connection.
What if the boiler is used only seasonally, for example in operation with intermittent heating?
In case of seasonal or intermittent operation, we recommend having a service technician check the free running of the pump and the condition of the heating water before restarting after a longer shutdown, as long-term stagnation of water in the system can promote the accumulation of impurities in the circulation part.
Additional parameters
| Category: | Vaillant – valves, insulation and installation kits |
|---|---|
| Warranty: | 2 years |
| Brand: | Vaillant |
| Product type: | High-efficiency circulation pump with connection fitting |
| Intended for: | ecoTEC plus VU 806/5-5, VU 1006/5-5, VU 1206/5-5 (80, 100 and 120 kW) |
| Pump energy efficiency class: | A (in accordance with ErP Regulation 641/2009) |
| Speed control: | Continuous, electronic, according to boiler modulation and the set control mode |
| Pump body material: | Cast iron / stainless steel rotor circulation part depending on design |
| Included in delivery: | Pump, connection fitting, seals, mounting material |
| Connection: | Flanged/screwed connection matching the ecoTEC plus 80-120 kW heating circuit outlet |
| Max. operating temperature: | up to 110 °C |
| Max. operating pressure: | up to 6 bar |
| Country of origin: | Germany / EU (Vaillant Group) |
| Warranty: | 24 months |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.