WIGELL Floor Manifold, 17 circuits, brass + manual air vent
Code: JEZ_WG01.0310716Product detailed description
The underfloor heating manifold is the main component for even heat distribution in underfloor heating systems. Manifold variants include different numbers of circuits, usually from 2 to 18, and are compatible with underfloor heating pipes with diameters of 16–20 mm.
Wigell manifolds can be mounted directly on the wall or, using the supplied brackets, into a manifold cabinet. The mounting position is arbitrary. Using compression fittings, you can connect PeX-AL-PeX or Pe-rt pipes to this manifold.
Product parameters
- Permissible liquid temperatures: -10 °C to 120 °C
- Max. working pressure: 4 - 6 bar
- Max. test pressure: 10 bar
- Measuring range: 0-5 l/min
- Flow rate: 1.12 m3/h
- Inlet and outlet connection: 1"
- Flow meters: dual-regulation with lockable option
Advantages of Wigell manifolds
- Each manifold undergoes a pressure test, which ensures its reliability and long service life.
- You can choose a manual or automatic air vent.
- The cabinet size is precisely designed for the given number of circuits and fits perfectly.
- The control valves can be chosen in two variants with thermometer preparation, either angled or straight.
- The manifold is fitted with control valves, flow meters and air vents.
Pressure test video
This manifold assembly consists of
Heating water body:
- flow meters terminated with a nipple and a PEX 3/4 x 16 coupling
- air vent and drain unit with a manual air vent (an automatic air vent can also be used)
Return water body:
- thermostatic valves M30 x 1.5 - option to install thermal actuators
- nipples with installed PEX 3/4 x 16 couplings
- air vent and drain unit with a manual air vent
Flow meter:
It is used to set the heating water flow rate in l/min and thus to balance the pressure differences of individual heating circuits. Depending on the direction you turn the bottom part of the flow meter, you decrease or increase the heating water flow, or shut it off completely. On the transparent part of the flow meter, the water level shows the flow rate in l/min. Max. operating pressure is 1 MPa.
Thermostatic valve inserts with manual heads are used to shut off individual heating circuits. These manual heads cannot be used to regulate individual branches. The manual heads can be removed and replaced with electric actuators.
Air vent and drain unit:
Used to vent the heating system. The air vent valve of this unit is manual (key-operated), and can be replaced with an automatic air vent valve.
What else to buy for the air vent?
Additional accessories are needed for proper connection. Below, select the connection components that are fully compatible with this manifold:
- Flush-mounted and surface-mounted cabinets
- Mixing sets (WILO pump + ESBE valve) - for variants without a built-in pump
- Ball valves for connection without a circulation pump
- Compression fittings
When laying the pipes, we also recommend buying:
- Underfloor heating pipes
- Underfloor heating foils
- Clips for securing floor pipes
- Staplers and dispensers
- Expansion tapes for the wall
Packaging and delivery method
We will deliver the product to you via standard parcel shipping and it will be packaged so that it is not damaged during transport. The actual packaging method depends on the number of pieces ordered and other order items. A single manifold is most often packed in a cardboard box and stretch film.
Additional parameters
| Category: | Brass Manifolds |
|---|---|
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!