ATMOS D 25 P
Code: D25PProduct detailed description
- 7-24k W ecological, fully automatic boiler for pellets only

- it is designed for perfect combustion of pellets in such a way that a pellet burner is built into the left or right side of the boiler, depending on the customer's needs, which fully automatically draws pellets from the hopper using a screw conveyor. The fuel hopper is usually placed next to the boiler or in an adjacent room and can be of any size (standard 250, 500 or 1000L). A part of the boiler room is also often used as the fuel hopper, which is then sufficient for the entire heating season.
The operation of the pellet burner itself is fully automatic. If the burner receives a start command or if there is a need for heating, the conveyor feeds pellets into the burner nozzle and it ignites them itself with a heating element (spiral). After sufficient ignition of the pellets, the burner runs up to the set output, which it maintains until the system (house) is heated. Then the burner switches off and the pellets in the burner chamber burn out completely. The burner is then ready for a new start. The whole cycle repeats again whenever further heating is needed.
The boiler output and other burner functions are controlled by electronic regulation, which allows the boiler operation to be adapted to the specific conditions of the entire system. Refilling pellets, cleaning the burner combustion chamber and removing ash is carried out once every 1 – 30 days, depending on the quality of the pellets and the size of the hopper.
If required, the boilers can be equipped with an automatic ash removal system for comfortable heating with minimal operator attention.
|
Basic technical data Atmos D25P:
Note: |
| Required accessories for the boiler: | ||
burner A25 |
screw conveyor DA - various lengths |
![]() pellet hopper - various |
|
Advantages of ATMOS pellet boilers:
|
Frequently Asked Questions
- How to choose the right boiler output for a solid fuel boiler? Base your choice on the calculated heat loss of the heated building; however, for wood/coal boilers, also consider that the boiler burns for several hours at essentially constant output during one filling - therefore it is common practice to add a buffer tank to the boiler, which stores excess heat for later use instead of the boiler having to be inefficiently dampened down.
- What else do I need to install this boiler? In addition to the boiler itself, the system usually requires: a buffer (equalization) tank of adequate volume, a circulation pump (often already with a built-in Laddomat or thermoregulatory valve to prevent low-temperature corrosion of the boiler), a safety valve, an expansion tank, and a flue/chimney with sufficient draft corresponding to the boiler output - exact draft values can be found in the technical parameters above.
- What fuel is suitable and what is not? Use only fuel recommended by the manufacturer for the given model (typically split wood of a defined length and moisture content, or brown coal briquettes or coal depending on the boiler type) - unsuitable or too moist fuel reduces efficiency, increases tar and deposit formation, and can cause damage to the boiler.
- What about chimney inspection and legislation? Before putting the boiler into operation, as well as regularly during its use (usually once a year for solid fuels), a chimney inspection/cleaning by an authorized chimney sweep is required by law - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputed.
- How much maintenance does the boiler require? This usually includes regular removal of ash and cleaning of heating surfaces/flue gas paths from soot (interval depending on intensity of use, usually a matter of weeks), and once a year a thorough inspection including seals and the chimney.
- Can I install the boiler myself? The actual placement and connection of the boiler to the heating system, chimney and safety elements should be performed or at least professionally checked by a heating technician - this is a device with an open flame, high temperatures and pressure elements, where an error in connection can be a safety risk.
Additional parameters
| Category: | kotly |
|---|---|
| Warranty: | 2 years |
| Weight: | 285 kg |
| Boiler output: | 7 – 24 kW |
| Boiler weight: | 254 kg |
| Combustion Class: | 5 |
| Combustion chamber volume: | 88 dm³ |
| Dimensions (H / W / D): | 1207/ 620 / 868 mm |
| Efficiency: | 90,2% |
| Energy efficiency class: | A+ |
| Heating surface: | 2 m² |
| Max. water working pressure: | 250 kPa |
| Minimum buffer tank volume: | 500L |
| Objem vody v kotli: | 62 L |
| Required chimney draught: | 22 Pa |