AVANSA 100M gas detector + solenoid valve G3/4", DN 20
Code: AVANSA PLYNOVY DETEKTOR -100MM-S VENTILORelated products
Product detailed description
AVANSA 100M gas detector + solenoid valve G3/4", DN20
Installing a gas detector can prevent poisoning, suffocation, fire or explosion. The detector can detect a gas build-up before it becomes life-threatening. Detection is local, both visual and audible.
The electromagnetic solenoid valve is a special safety device used to shut off the main gas supply in emergency situations. It can be connected to a leak-monitoring system (gas detector) to automatically shut off the gas supply.
Detector technical parameters:
- Power supply: AC 220V 50Hz
- Sensitivity: 10% L.E.L. (lower explosive limit)
- Response time: < 30 s
- Power consumption: normal operating mode < 1.5 W - alarm 3 W
- Operating temperature: -15 °C... - 50 °C
- Humidity: < 97% RH (relative humidity)
- Alarm volume: > 90 dB at a distance of 1m from the detector
- Polarity: white wire (+) positive, black wire (-) negative
- Weight: 250 g
- Detectable gases: natural gas (methane), LPG (butane, propane)
- Can be connected to a 12V DC solenoid valve
Valve technical parameters:
- Gas types: natural gas (methane) and LPG (butane, propane)
- Solenoid body: brass alloy, nickel
- Sealing material: NBR/EKM rubber
- Operating temperature: -10 °C... + 50 °C
- Connections: G3/4" DN20
- Opening: manual
- Closing: 9 V DC - 12 V voltage or manual
- Closing current: < 1.5 A (pulse)
- Closing time: < 1 s
- Polarity: white wire (+) positive, black wire (-) negative
- Maximum pressure: 500 mBar (max. 1 bar pressure test for 20 minutes)
Frequently Asked Questions
- How do I check compatibility with my valve/system? Compare the connection type (e.g. thread M30x1.5) and supply voltage with the technical parameters of your valve or control system.
- Must installation and wiring be carried out by a professional? Mechanical fitting onto the valve can be handled by a DIYer; we recommend having the electrical wiring to the control system checked by an electrician or heating technician.
Additional parameters
| Category: | Fire and smoke alarms |
|---|---|
| Warranty: | 2 years |
| Power supply: | AC 220V 50Hz |
| Material type: | rubber NBR/EKM Operating temperature |
| Operating temperature: | -15 °C... - 50 °C |
| Alert volume: | > 90 dB pri vzdialenosti 1m od detektora |
| Closing Current: | < 1,5 A (impulz) |
| Closing time: | < 1 s |
| Humidity: | < 97% RH (relative humidity) |
| Maximum pressure: | 500 mBar (max. 1 bar pressure test for 20 minutes) |
| Otvorenie: | manual |
| Pripojenia: | G3/4" DN20 |
| Response time: | < 30 s |
| Sealing Material: | guma NBR/EKM |
| Sensitivity: | 10% L.E.L. (lower explosive limit) |
| Solenoid valve connection option: | 12V |
| Spotreba energie: | in normal operating mode < 1.5 W - alarm 3 W |
| Telo solenoidu: | brass alloy, nickel |
| Uzavretie: | 9 V DC - 12 V voltage or manual |
| Weight: | 250 g |
| EAN: | 5949040800087 |
| Rozmer balenia (mm): | 70/230/140 |
Video Detektor plynu AVANSA 100M + solenoidový ventil G3/4", DN 20
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
S
Stano
Dobrý den,
zakoupil jsem u vás detektor plynu Avansa 100M LPG+ elektromag. ventil, a na výstupu při aktivaci plynem nemůžu naměřit napětí 12V DC, jak je v návodu uvedeno. Zkoušel jsem to jak s plynem tak i pomocí tlačítka, při zapnutí do zásuvky jsem počkal až se čidlo kalibruje pak jsem ze zapalovače udělal falešný poplach ale na výstupu voltmetr nic nenaměřil. I když teď mě napadlo jestli toto čidlo nemá časovou prodlevu, takže možná kdybych déle přiváděl plyn tak se možná napětí na výstupu objeví. Můžete mi poradit?
S přáním pěkného dne Stanislav
A
ATRIA.SK
Dobrý deň,
preposielame odpoveď od dodávateľa :
"Napätie je len impulz na veľmi krátku dobu, je vyrobené pre prácu s 12V solenoidovým ventilom. Nemôžete to zmerať voltmetrom, pretože to trvá len sekundu." Pekný deň.
J
jan
Dobrý deň, mám záujem o kúpu "Detektoru plynu AVANSA 100M + solenoidovým
ventilom
". Zaujímam ma či je snímač detektoru plynu možné vymeniť a v akých intervaloch? Alebo treba kúpiť celý detektor a v akých intervaloch? A ohľadom elektroventilu ma zaujíma či v prípade vypadnutia dodávky elektrickej energie sa elektroventil automaticky uzavrie, a ak by sa neuzavrel tak či treba schému zapojiť so záložným zdrojom? Za zodpovedanie otázok Vám vopred ďakujem.
A
atria
Dobrý deň, nedá sa meniť je potrebný nový. Áno elektroventil sa uzavrie. Pekný deň.
J
jan
Dobrý deň, ďakujem Vám za Vašu odpoveď, prosím o zaslanie cenovej ponuky pre objednanie "Detektor plynu AVANSA 100M + solenoidovým ventilom" so snímačom pre CH4 - zemný plyn.
J
jan
Dobrý deň, na e-mail Vám zasielam želanú CP na u nás dostupný tovar. Pekný deň
R
riso
Ked pri vypadku el. sa ventil zavrie, pri opatovnom zapnuti el. prudu sa ventil otvori ?
A
atria
Dobrý deň, nie neotvorí, treba ručne. Pekný deň.