Product detailed description
Stainless Steel Manifold, 4-way, for Underfloor Heating
The manifolds are made of high-quality stainless steel according to the German standard DIN EN 1264-4:2009-11. The manifolds can be used with all types of plastic pipes, including multilayer pipe and copper. Pipes are connected using a 3/4"EK compression fitting. Manifolds for underfloor heating are equipped with dual-control flow meters with a flow indicator (Regolux 0-5L/min) with memory, and thermostatic valves (with M30 x 1.5 connection) on each circuit, so that each heating circuit can be regulated separately. The manifold also includes automatic air vent valves, rotary drain valves and nickel-plated brackets. Country of origin: Germany
Frequently Asked Questions
- How can I check that this part fits my HEPWORTH pipe? Compare the size (pipe diameter in mm or the inch thread) given in this product's name with the diameter of your pipe - the HEPWORTH system uses its own precisely defined size ranges.
- Does installation have to be carried out by a professional? Clips, anchors and wall plates are standard installation accessories intended also for DIY installation; however, we recommend having the connection of the piping into a functioning heating or plumbing system checked by a professional.
Additional parameters
|
|
Stainless Steel Manifolds |
|
|
2 years
|
|
|
5999093608925
|
|
|
Press-Messing Ms 58, nickel-plated |
|
|
295mm |
|
|
345mm |
|
|
Nemecko |
|
|
heating water, cooling water, water mixtures with standard anti-corrosion antifreeze additive |
|
|
brass, heat-resistant plastics, stainless steel 1.4301 |
|
|
4 - 6 barov |
|
|
+ 80 °C |
|
|
6 barov |
|
|
10 barov |
|
|
PEX-AL-PEX 16 x 2 |
|
|
Compression fitting for ALPEX 16 x 2 ALU-EK pipe |
|
|
Manifold cabinets |
|
|
WS 3825 |
|
|
four |
|
|
+/- 10 % |
|
|
1,12 m3/h |
|
|
dual-regulation with locking option |
|
|
Ek, Eurokonus |
|
|
1" |
|
|
- 10 °C to 120 °C |
|
|
0-5 l/min |
|
|
EPDM |
|
|
heating and cooling systems |
|
|
DIN ISO EN 228-1 |
|
|
DIN 4109 |
Product rating
Be the first who will post an article to this item!
5,0
The average product rating is 5,0 out of 5 stars.
1 rating
List of ratings
Discussion
List of discussions
Dobrý den existuje regulovač kombinovaný pre podlahove kurenie a radiatory.Ďakujem
Dobrý deň,
áno existuje, ale u nás nemáme dostupný tento tovar. Pekný deň.
Dobrý deň,chcem sa opýtať čo konkrétne potrebujem na podlahové kúrenie,keďže chcem ovládať každú izbu samostatné s termostatom.Povedali že potrebujem nejaké spínacie zariadenie ktoré bude brať signál od termostatu.Mám ja káble od termostatov natiahnuté ku krabici kde sú jednotlivé ventily na otváranie prívodu na každý okruh podlahovky.Mám kondenzačný kotol Junkers cerapur smart 22-3 so 120l bojlerom na vodu.Ďakujem pekne.
Dobrý deň. Práve to je ono, čo som poslal. Servomotor dáte na každú hlavicu, teda vetvu rozdeľovača. Potom použijete rozvodnicu, tá slúži ako regulátor. Pripája sa na ňu termostat z izby a ovláda vlastne servo na jednotlivých vetvách rozdeľovača.
Mne povedali že potrebujem len nejaké spinacie ventily,lebo teraz tam mám len klasický ventil na každý okruh ktorý len otvorím alebo zavriem.Keď chcem regulovať každú izbu samostatné že potrebujem spinaciu hlavicu alebo ako sa to odborné volá,ktorá bude brať príkaz z termostatu v danej izbe a podľa toho pootvori alebo privrie vodu do podlahovky.To čo ste mi poslali sa mi zdá akoby úplne nový systém pre ovládanie kotla.Alebo tomu nerozumiem,čo je pravda lebo mám prvý krát kotol.
Dobrý deň. V tomto prípade potrebujete rozvodnicu a jednotlive servomotory na ventile rozdeľovača https://www.atria.sk/vykurovacia-technika/rozdelovace-nerezove/regulacia-rozdelovacov/. Pekný deň.
Dobry den, chcem sa spytat mozno trocha netypicku otazku ohladom rozdeľovača pre podlahové vykurovanie s regulatorni prietoku. Je mozne ho instalovat tak povediac "obratene" to znamena privodne trubky by boli napajane zhora a nie odspodu.... odvzdusnovacie ventily by sa prehodili... popripade aj ostatne ak je to mozne .. Vopre vdaka za spatnu vazbu.
Dobrý deň. Áno, môže sa to, lebo tieto prietokomery nefungujú na gravitáciu ale je tam pružina, ktorou ťahá voda a tak je jedno ako je uložené. Pekný deň.
Dobry den,chcem sa spytat ci mate v ponuke aj rozdelovace na pitnu vodu.kupoval som u Vas potrubie alpex 20mm a srobovacie fitingy a potreboval by som nieco na rozdelenie jednotlivych vetiev teplej aj studenej vody aby spojky nemuseli byt pod omietkou ani v betone.vdaka
Dobrý deň. Kliešte nepotrebujete. Použijete normálny kľúč. Pekný deň.
Dobrý deň, Ďakujem za odpoveď. Ešte posledná otázka. Na tieto fitingy potrebujem kliešte typ U alebo TH? https://www.atria.sk/zverne-srobenie-na-potrubie-alpex-16-x-2-alu-ek-500684/ https://www.atria.sk/zverne-srobenie-so-vsuvkou-3-4-x20x2-alu-vonkajsi-zavit/ Máte na to kliešte skladom?
Dobrý deň. Nakoľko musíte mať prívod na potrubie pexalpex, tak všetko pôjde za sebou nasledovne: potrubie https://www.atria.sk/potrubie-pex-al-pex-20-x-2/ potom pripojenie k ventilu https://www.atria.sk/zverne-srobenie-so-vsuvkou-3-4-x20x2-alu-vonkajsi-zavit/ 2x ventil https://www.atria.sk/gulovy-ventil-pre-nerezovy-rozdelovac-3-4-x-1/ 2x a nakoniec ten rozdelovač čo máte. Pekný deň.
Dobrý deň. Kúpil som u Vás: https://www.atria.sk/potrubie-pex-al-pex-16-x-2/ https://www.atria.sk/nerezovy-rozdelovac-5-cestny-pre-radiatory/ https://www.atria.sk/zverne-srobenie-na-potrubie-alpex-16-x-2-alu-ek-500684/ a potrebujem k tomuto rozdeľovaču dorobiť prívod. Chcel by som od Vás poradiť, čo všetko mám kúpiť. Potrebujem tam 2 kolienka 90°, 2 guľové ventily, prívodnú rúru pex-al-pex, nejaké šróbenia na ňu... Neviem, či treba aj nejaké tesnenia medzi ventily, kolienka a šróbenia. Či tam treba aj nejaké poisťovacie ventily, či sa dajú dať priamo na ten rozdeľovač... Mohli by ste mi poradiť, prosím Vás?
Dobrý deň. Originálny rozdeľovač na vodu pri pexalpex v podstate nie je. Napríklad u systému Hepworth sa používa tento: https://www.atria.sk/vykurovacia-technika/kurenie-svojpomocne-hepworth/rozdelovace-plastove/ ale kľudne môžete použiť tento nerezový: https://www.atria.sk/vykurovacia-technika/rozdelovace-nerezove/rozdelovace-pre-radiatory/ alebo potom klasické T-kusy. Pekný deň.
Veľmi pekne ďakujem za konzultáciu. Ešte mám jednu otázku: v takto zapojenom systéme je nutné mať na radiatoroch termostatické hlavice? Logika mi hovorí, že ak mám priestor monitorovaný termostatom, ten mi reguluje kotol - na radiatore stačí klasický ventil, ale možno sa mýlim.
Dobrý deň, netreba mať termostatické hlavice - ak sú tak sa otvoria doplna. Ak Vám bude horúco tak si len rýchlo uberiete na radiátore... Kým sa ale termostat vypne a zatvorí servo to bude trošku trvať. Pekný deň.
Ďakujem veľmi pekne za návrh komponentov na zónovú reguláciu. Trochu som nad tým špekuloval a chcem sa opýtať či by bolo možné zapojenie podľa prílohy (KURENIE 3). 1. je možné zapojenie viacerých rozdelovačou za sebou? 2. majú rozdelovače dostatočný prietok na zásobovanie radiátorov teplou vodou? 3. sú priemery plasthliníkových trubiek dostatočne dimenzované? 4. zóna 3 je napojená priamo bez elektrotermickej hlavice - slúži ako by-pass 5. HPW rozvodnica dokáže ovládať 6 termostatov, čiže je možné celé zapojenie rozdeliť na 6 zón? Ďakujem za odpoveď
Dobrý deň, takýmto spôsobom ako v prílohe (Kurenie 3) to zapojenie nemôže byť v žiadnom prípade. Zóna 1 má 5 radiátorov, tie musia byť napojené na rozdeľovač a ten priamo od kotla aspoň s pexalopex 20 https://www.atria.sk/potrubie-
pex-al-pex
-20-x-2/, nie z ďalšej vetvy ďalšieho rozdeľovača pred ním, atď pre zónu 2,3,4. Taktiež zóna dva musí mať napr. ten Euroster regulátor, nie CW100 ako je na obrázku, ten bude slúžiť ako hlavný termostat kotla. Predstavme si, že namiesto tohto http://prntscr.com/ia9622 rozdeľovača má byť kotol. Jednotlivé zóny sa budú ovládať cez štyri rozvodnice, ku každej jednej je potrebný termostat a serva. Tým pádom aj zapojenie v kurenie2.pdf nieje dobre. Jednoznačne tam musí byť tento rozdeľovač http://prntscr.com/ia96rd vymenený za kotol. Posledným riešením je ešte napríklad použiť kotlové zostavy https://www.atria.sk/vykurovacia-technika/nerezove-kotlove-zostavy/. Pekný deň.
Ak som správne pochopil, priame pripojenie od kotla musí ísť do rozdelovača - je možné zapojenie podľa prílohy? (KURENIE 4) V takomto prípade asi bude nutné mať ešte v systéme anuloid.
Áno kúrenie 4.pdf je správne, v tomto prípade prívod a spiatočka aspoň s pexalpex 26. Bude potrebné použiť asi 4 rozvodnice, alebo menej pokiaľ viete prepojiť aj dva rozdeľovače k jednej. Lebo môžete mať až 24 servopohonov na jednu a 6 termostatov. Viac info o zapojení môžete nájsť tu : https://www.atria.sk/soubory/26058/navod-na-obsluhu-pre-svorkovnici-podlahoveho-vykurovania-salus-kl06%20(2).pdf Anuloid nieje až taký potrebný, nemyslím že by naraz zatvorilo všetkých x hlavíc. Pekný deň.
Samotný rozdeľovač je super ale tento mix má vážne konštrukčné vady. Tá najvážnejšia - aj keď otvoríte ventil naplno, berie to 90% studenej vody zo spiatočky. Jeden sa mi pokazil počas prevádzky a druhý nefungoval od samého začiatku - nebolo možné dostať teplú vodu do podlahy. Oba mixy som vyhodil preč a v momente systém začal kúriť! Nekupujte to, sú to vyhodené peniaze. Dobré je z toho snáď len to čerpadlo Dab Evosta za príplatok a teplomer. Nič iné. Druhý problém je, že ak sa vzduch dostane do komory s teplomerom, už sa odtiaľ nedostane inak než demontážou. Tretí problém je, že mix má špeciálne vstuvky s nastaveným tesnením. Ak sa to tesnenie pokazí, náhradné nikde nezoženiete. Opakujem, rozdeľovač áno, mix rozhodne nie. Treba však zabezpečiť aby teplota vody do podlahy neprekročila 50°C u anhydritu a 40°C u betónu.