Dražice OKC 160 NTR/BP
Code: 120670101Related products
Product detailed description
Indirect heating stationary water heater, boiler Dražice OKC 160 NTR/BP for water heating
Possibility of additional installation of a heating flange type TPK 168 - 8 and for volumes of 200, 250, 300 litres a threaded TJ G 6/4" body
Most common use:
Year-round heating of domestic hot water using water from a gas boiler for connection with priority DHW heating. For the OKC x NTRR type, a combination of a gas boiler and an alternative energy source is possible, or when connecting both heat exchangers in series, an indirect heating tank for boilers over 24 kW.
A newer range of enamelled indirect heating water heaters for floor standing installation with volumes of 100–300 litres, featuring an enamelled tank and a powerful single heat exchanger, or from the 200-litre type onwards two heat exchangers for DHW heating from an external source or a combination of different sources. By connecting both heat exchangers in series, a DHW source with an output of up to 57 kW can be achieved. The heater is equipped with DHW temperature control (a thermostat for controlling a three-way valve or circulation pump) for 230 V/50 Hz voltage, up to 200 litres a safety valve, and a circulation outlet.
In the lower part of the heater there is an inspection flange opening for cleaning the inside of the tank and for the possible insertion of an auxiliary electric heating element of the TPK range from the accessories. For using the heater in a solar system, heaters over 200 litres have a 6/4" fitting available, located above the solar heat exchanger, for the TJ electric heating unit from the accessories section.
| Type | OKC 100 NTR/BP | OKC 125 NTR/BP | OKC 160 NTR/BP | OKC 200 NTR/BP | OKC 250 NTR/BP | OKC 300 NTR/BP |
|---|---|---|---|---|---|---|
| Volume [l] | 95 | 120 | 155 | 210 | 250 | 300 |
| Weight [kg] | 59 | 72 | 82 | 97 | 106 | 111 |
| Heater height [mm] | 815 | 980 | 1 018 | 1 328 | 1 508 | 1 597 |
| Heater diameter [mm] | 524 | 524 | 584 | 584 | 584 | 670 |
| Maximum operating pressure of tank [MPa] | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 |
| Maximum operating pressure of heat exchanger [MPa] | 1 | 1 | 1 | 1 | 1 | 1 |
| Maximum heating water temperature [°C] | 110 | 110 | 110 | 110 | 110 | 110 |
| Maximum DHW temperature [°C] | 80 | 80 | 80 | 80 | 80 | 80 |
| Heating surface of lower heat exchanger [m2] | 1,08 | 1,45 | 1,45 | 1,45 | 1,45 | 1,5 |
| Heating surface of upper heat exchanger [m2] | – | – | – | – | – | – |
| Output of lower/upper heat exchanger (LHE/UHE) [kW] | 24 | 32 | 32 | 32 | 32 | 35 |
| Continuous output DHW.*/LHE ./UHE . [l/h] | 610 | 990 | 990 | 990 | 990 | 1 100 |
| Heating time from 10 °C to 60 °C (by heat exchanger) [min] | 14 | 14 | 17 | 22 | 28 | 24 |
| Heating time by electric energy from 10 °C to 60 °C (2,2 kW) [hr] | 3 | 3,5 | 4,5 | 5,5 | 7 | 8,5 |
| Heating time by electric energy from 10 °C to 60 °C (3–6 kW) [hr] | – | – | – | – | – | 6–3 |
| Electrical protection rating | IP 44 | IP 44 | IP 44 | IP 44 | IP 44 | IP 44 |
| Heat losses [kWh/24 hr] | 0,9 | 1,05 | 1,39 | 1,4 | 1,72 | 1,86 |
Additional parameters
| Category: | indirect-heated stationary |
|---|---|
| Warranty: | 2 years |
| Weight: | 20 kg |
| The item has been sold out… | |
Product rating
Be the first who will post an article to this item!