Clamp-on thermostat AVANSA TH 2A
Code: 312034Product detailed description
Clamp-on thermostat AVANSA TH 2A for circulation pump
- used to switch on or off any contact, most often an electrical contact (pump phase) - thereby switching the circulation on or off
- this allows the pump to be easily controlled, for example the boiler circuit of a solid fuel boiler, or the charging of a storage tank or a DHW cylinder
- the thermostat can be easily clamped onto the pipe and secured on the other side with a strap so that it does not come loose
- the clamp-on thermostat contains a bimetal element, which by bending activates the contact to switch on or off.
Parameters:
- safety clamp-on thermostat with a spring for fixing to the pipe or manifold
- can be connected as a switch-on or switch-off thermostat
- voltage: 230 V
- temperature range: 20 - 90 °C
- temperature differential: 8-3 °C
- protection rating: IP 20
- insulation class: I
- rate of temperature change: < 10 °C/min
- maximum controlled temperature: 85 °C
- storage temperature: -15 °C to 60 °C
- output: changeover contact
The bimetallic contact thermostat is used for control depending on the temperature of the heating medium in the pipes on which it is mounted. It can be mounted on pipes up to a maximum diameter of 2" using a flexible steel clamp, which ensures contact between the thermostat and the pipe.
Use:
Thermostat for temperatures from -15°C to 60°C with an 8°C differential. The selected temperature
is set using a knob. The thermostat is mounted directly onto the hot-water pipe and fixed with a spring.
The thermostat has three contacts (switches from terminal 1 to terminal 2). It is most often used to control the run-on of the boiler pump. It is also suitable for switching off the pump in underfloor heating as a safety thermostat.
Frequently asked questions
- How do I check that this part is compatible with my manifold? Compare the thread/connection type (e.g. Eurocone EK, M30x1.5) and the dimension given in this product's name with the technical data of your specific manifold - brass manifolds from different manufacturers may have different connection dimensions.
- Must the installation be carried out by a professional? Fitting simple parts (brackets, fittings, flow meters) onto an already installed manifold can be handled by a skilled DIYer; we recommend having the connection to a functioning heating circuit and its balancing checked by a heating technician.
- Why is brass a common material choice for manifolds and their accessories? Brass is a long-proven material resistant to corrosion in water/heating systems, easy to machine into precise threads, and able to withstand the typical operating temperatures and pressures of heating water.
Additional parameters
| Category: | pump and boiler room thermostats |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.18 kg |
| Storage temperature: | -15 °C to 60 °C |
| Insulation Class: | I |
| IP Rating: | IP 20 |
| Maximum controlled temperature: | 85 °C |
| Operating Temperature Range: | 20 - 90 °C |
| Outlet: | changeover contact |
| Rate of Temperature Change: | < 10 °C/min |
| Temperature Difference: | 8-3 °C |
| Voltage: | 230 V |
| Rozmer balenia (mm): | 60/130/70 |
Product rating
Be the first who will post an article to this item!
The average product rating is 5,0 out of 5 stars.
2 ratings
5
4
3
2
1
Leave a rating
List of ratings
Discussion
List of discussions
P
Pavol
Dobrý deň. Chce sa Vás opýtať, že či pri osobnom odbere produktu platia otváracie hodiny iba cez týždeň, alebo je ešte možnosť si tovar vyzdvihnúť cez víkend ? (Sobota) ? Ďakujem S pozdravom Ferianec
A
ATRIA.SK
Dobrý deň,
tovar si je možné vyzdvihnúť iba v otváracích hodinách a teda PO - PIA 07:15 do 15:45. Pekný deň.
G
Gabika
A
Atria
Dobrý deň, áno je vhodný.
Pekný deň.
LT
Ladislav Tuček
Dobrý deň,
mám kotol na pevné palivo. Na prízemí mám podlahové kúrenie a na poschodí rádiátory. Potrebujem aby mi zapínalo čerpadlo na podlahovke na prízemí pri 40 C a vypínalo pri 20 C. Aký termostat sa hodí?
Ďakujem Laco.
I
Ivan
D
Damian
Dobrý den. Ja potrebujem poradit ohladom termostatu k obehovemu cerpadlu. JA by som potreboval termostat ktoreho cidlo mozem namontovat do pripraveneho otvoru na ruru od kotla. Pan ktory nam to montoval urobil 1/2 colovy otvor s vnutornym zavitom s tym ze sa takyto termostat s ponornym cidlom da kupit. Ja by som potreboval poradit termostat ktory taketo ponorne cidlo obsahuje. Vopred velmi pekne dakujem
A
ATRIA
Dobrý deň, v tom prípade máme dva termostaty, tento https://www.atria.sk/prilozny-termostat-salus-at10f/ a tento ktorý sa nastavuje elektronicky s možnosťou nastavenia hysterézie https://www.atria.sk/elektricky-termostat-adex-ttuv/. Pekný deň.
M
Milan
kupil som termostat salus at 10 prilozil na ruru nad kotlom fazu zapojil na c a potom cez kontakt 1 na obehove cerpadlo s uzemnenim no rura je horuca na 70 stupnov a termostat nezopneako keby nereagoval na zmeny teploty
A
ATRIA
Dobrý deň, fázu čerpadla musíte zapojiť napríklad na C a potom fázu od steny, teda prívodnú musíte dať na 2. Skúste, musí to fungovať, ešte sa nám nikdy nevrátil zlý výrobok. Pekný deň.
L
Lubomir
Dobrý deň, originál termostat len na obehové čerpadla nieje, potom jedine tento https://www.atria.sk/salus-eurotemp-11m/, lenže ten ovláda aj trojcestný ventil a neviem či by to správne fungovalo. Na riadenie čerpadla sa používa ten malý príložný, alebo potom tieto https://www.atria.sk/prilozny-termostat-salus-at10/, https://www.atria.sk/eurotemp-11c/ a https://www.atria.sk/elektricky-termostat-adex-ttuv/
O
Ondrej
M
Martin
Dobrý deň, tovar Príložný termostat SALUS AT10 môžem zapojiť tak aby mi zapínal čerpadlo pri cca 55 C a vypínal čerpadlo ked klesne teplota vody pod 55 C? Dakujem
A
ATRIA
Dobrý deň, áno je presne na to určené. Pekný deň.
E
edo
A
ATRIA
dobrý deň, treba ho nastaviť na vyššiu teplotu, ak nefunguje, tak reklamácia. Pekný deň
Z
Zdeno
Dobrý deň, potreboval by som ovládanie na obehové čerpadlo pdlahového kúrenia zn. IVAR za rozumnú cenu. Ďakujem
A
ATRIA
Dobrý den, čerpadlo môžete ovládať klasickým príložným termostatom https://www.atria.sk/prilozny-termostat-salus-at10. Pekný deň.
O
Ondro
Dobrý deň, mám otázku. Potrebujem vymeniť príložný termostat na čerpadle, pretože mi prestal spínať medzi teplotami 40-60. Kúpil som nový - Campigni Corel TS5310 (iný nemali), a ten má rovnaký štýl pripájania ako je Salus AT10. Na mojom kotli mám však príložný termostat, ktorý má 4 kontakty a neviem zistiť jeho značku. Dá sa to nejako vymeniť = zapojiť ten nový, alebo musím niekde skúsiť zohnať podobný so 4 kontaktmi? Vedeli by ste mi v tom prípade poradiť kde? Neviem ho nikde nájsť. Ďakujem
A
ATRIA
Dobrý deň, Žiaľ s vašim problémom Vám poradiť neviem. Prajem Vám pekný zvyšok dňa.
L
Lukáš
Zdravim potreboval by som Termostat s presnostou 0,1-0,5 do 40C
A
ATRIA
Pozeral som všetky termostaty a našiel som jediný, ktorý ma rozsah riadenia do 45 stupňov https://www.atria.sk/salus-eurotemp-st-320/. Ostatné máju do 35-40. Takže asi len tento, iný nemáme. Pekný deň
L
Lukáš
Potrebujem na snimanie teploty v malom priestore 40C-stupnov odchylka 0,1-0,5 konkretne do liahne alebo odchovne na vajicka.
A
ATRIA
Dobrý deň, neviem aký termostat myslíte, príložný, či na kotol?
M
Milan
zdravim ako mam prosim vas zapojit pripožny termostat SALUS AT10 k obehovemu čerpadlu ktori mam ku kotlu na drevo .mam na mysli na ktore svorky Cje privod a 1.2 to neviem potrebujem ked sa teplota dostane na 60 stupnou tak by sa mal spustit, dakujem za odpoved
M
Milan
myslím na ktorú svorku zapojiť fázu a na ktorú nulak
L
Lubomir
Dobry den potreboval by som poradit ako zapojit priložny termostat ARTH300 k obehovemu čerpadlu,na termostate su 4 konektory uzemnovaci, 1-2-4 Dakujem.
D
Dana
Dobry den,potrebujem poradit ako pripojit termostat Avansa th2 A k cerpadlu.na ktoru svorku treba napojit fazu a na ktoru nulak.dakujem
A
ATRIA
Dobrý deň, fázu treba dať na tú svorku, ktorá sa rozopína. Pekný deň
M
Milan
K
Kamil
Dobrý deň.
Prosím Vás o radu, že aký príložný termostat mám použiť k obehovému čerpadlu na kurenie ? Čerpadlo je ALPHA 1L 25-40 180.
Ďakujem
A
ATRIA
Dobrý deň,
môžete aj ten avansa TH2 alebo aj : https://www.atria.sk/avansa-110-e/
Pekný deň.
M
Milan
Dá sa nadstaviť príložný termostat AVANSA TH 2A tak, aby čerpadlo vypinal pri poklese teploty na 35 stupňov celzia ? Teraz vypína pri poklese na 25 stupňov. Ďakujem
A
ATRIA
Dobrý deň,
tak si nastavíte kedy sa má kontakt vypnúť tým kolieskom, ale rozdiel teploty vypnutia a zapnutia sa nedá nastaviť.
Pekný deň.