Electrothermal actuator 230 V
Code: 315100Product detailed description
The electrothermal actuator is mounted on the thermoregulating valve of an underfloor heating manifold and, on command from the thermostat/control, opens or closes the flow of heating water into a specific circuit - in the resting state (without power) it is closed, which is a safety advantage in the event of a power outage.
Electrothermal actuator AC 230 V
- suitable for thermoregulating valves with M30 x 1.5 thread
- for manifolds of type: FBH-VL-RL and FBH-S
- opening/closing time 180 sec., electric cable 0.6 m, 2 x 0.5 mm,
- can be manually opened to full flow or closed for maintenance,
- closed when de-energised.
Frequently Asked Questions
- How does this accessory work together with an underfloor heating manifold? Electrothermal actuators, wiring centres and thermostats together form the control of individual circuits on the manifold - the room thermostat evaluates the need for heat and, via the wiring centre, signals the specific actuator on the manifold valve to open or close the flow into that circuit.
- How can I check compatibility with my manifold/control system? Check the valve thread type (usually M30 x 1.5) and the supply voltage (230 V or 24 V) - these must not be mixed up between systems.
- Must the installation be carried out by a professional? A DIYer can fit the actuator onto the valve; however, we recommend having the connection to the electrical control system/wiring centre checked by an electrician or heating technician.
Additional parameters
| Category: | Manifold Controls |
|---|---|
| Warranty: | 2 years |
| For manifolds of type: | FBH-VL-RL a FBH-S |
| Rozmer balenia (mm): | 60/80/70 |
Video Elektrotermická hlavica 230 V
Product rating
The average product rating is 5,0 out of 5 stars.
1 rating
5
4
3
2
1
Leave a rating
List of ratings
Discussion
List of discussions
M
Martin
Dobry den rad bych Vas pozadal o zaslani podrobnejsich informaci o Vami nabizenych elektrotermickych hlavicich. A to jak mechanicke, tak elektricke paramentry. Budu menit ovladani ventilu ve dvou nemovitostech. V tento okamzik nevim, jestli budu volit variantu 24V nebo 230V. Velkym prinosem by pro mne byla moznost castecneho otevreni ventilu, napr pomoci PWM. V nekterych mistech planovane rekonstrukce topeni jsem castecne limitovany maximalnimi moznymi rozmery hlavice. Dale bych se rad zeptal na moznost ochrany pred neopravnenym prepnutim ventilu mezi polohou otevreno (zavreno) a automatikou Dekuji Martin
A
Atria.sk
Dobrý deň,
mrzí ma to, ale všetky dostupné informácie sú uvedené priamo na stránke.
Pekný deň.
M
Marián
Dobrý deň.
Prosím Vás aký je maximálny odber prúdu zariadenia?
Ďakujem za odpoveď.
A
ATRIA.SK
Dobrý deň, maximálny odber prúdu je 10A. Pekný deň prajem.
M
Michael
Dobry den, aky ma prosim hlavica zdvih v mm? V popise produktu to nie je uvedene. Dakujem.
D
Daniel
Ktore rozdelovace( na podlahove kurenie) pasuju na tieto hlavice?
D
Daniel
Napr. aj na ten sa da? A ako? Odmontuje tie cervene, a tam sa nakrutia? https://www.atria.sk/nerezovy-rozdelovac-11-cestny-pre-podlahove-vykurovanie/
A
ATRIA
Dobrý deň. Pasujú tam takmer všetky rozdeľovače na podlahové kúrenie. Napríklad aj tieto https://www.atria.sk/vykurovacia-technika/rozdelovace-nerezove/. Pekný deň
M
Miro
Dobrý deň, Táto termostatická hlavica je typ normal on, alebo normal close?
A
ATRIA
Dobrý deň, táto sa pod prúdom otvára. Pekný deň.
S
Stefan
prajem dobrý deň , kupil som u vas nerez rozdelovač 6 , vymenil so stary a chcel som pouzit ex. termopohony , ale ti mi nepasuju , zavit je v poriadku , ale ventily maju dlhy "stift" alebo terompohony kratky zavit , daju sa skratit , alebo existuje nejaka redukcia , dakujem za odpoved
A
ATRIA
Dobrý deň. Veľmi ma to mrzí ale tento manuál nemáme k dispozícií. Nastavenie prietokomerov by Vám mohol spraviť kurenár. Prajem pekný deň.
S
Stefan
zdravim , termopohony so si u vas objednal , potreboval by som ale manual nastavenia prietokomerov Regolux , dakujem
A
ATRIA
Dobrý deň, ide o nemeckého výrobcu Oventrop. Pekný deň.
S
Stefan
zdravím , viete mi povedat typ ventila resp. vyrobcu integrovaného v nerez rozdelovaci , dakujem
A
ATRIA
Dobrý deň. Podľa mojich informácií žiadna redukcia nieje. Myslím že budete potrebovať nové servo. Našu ponuku si môžete pozrieť tu: https://www.atria.sk/vykurovacia-technika/rozdelovace-nerezove/regulacia-rozdelovacov/ Prajem pekný deň.
O
Oliver
Dobry den, viete mi povedat ako pracuje tento system? Servo reguluje prietok alebo iba otvara na plny prietok a uplne zatvara?
A
ATRIA
Dobrý deň. Iba otvára a zatvára. To je všetko. Pekný deň prajem.
M
Marián
Dobrý deň chcem sa opytať aku hlavicu treba na regulovanie či pod prudom otvorenu. Alebo pod prufom zatvorenu ďakujem
A
ATRIA
Dobrý deň. Ak na klasické podlahové kúrenie, tak táto na ktorú sa pýtate. Táto je pod prúdom otvorená. Pekný deň.
M
Milan
Potrebujem termopohony na 230V Len neviem ako vaše pracuju či pod prudom zavrete alebo otvorene Dakujem vopred za vysvetlenie
A
ATRIA
Dobrý deň, termopohony môžete nájsť tu : https://www.atria.sk/elektrotermicka-hlavica-230-v/ Tieto sú bez napätia uzavreté. Pekný deň.