Thermona THERM EL 5
Code: 1607Product detailed description
Electric boiler with output modulation Thermona THERM EL 5
The THERM - EL electric boiler is designed by its construction for hot-water heating systems with forced water circulation. It can be installed in central and single-storey heating systems with forced circulation, in open or closed systems. It is an ecologically clean operation with no flue-gas discharge requirements. Unattended operation is enabled by an external controller or yesther external control/operating element (not included in the boiler's scope of delivery); alternatively, a simple weather-compensation controller or a room temperature controller built directly into the control automatics, maintaining a preset temperature in the selected room, can be used. The electric boiler can be used as a universal heat source for heating in apartments, small family houses and recreational buildings, as well as an alternative source when yesther main heating and hot-water source is used (even for a transitional period) - for heat pumps, accumulation systems, or in previously installed single-storey and central systems, etc. For higher outputs, the boilers can be linked into cascades.
Main advantages of THERM EL electric boilers:
- extremely fine smooth control in 9 output steps
- Therm EL 5 • min. output 500 W, rated output 4.5 kW, control step 0.5 kW
- Therm EL 9 • min. output 1000 W, rated output 9 kW, control step 1 kW
- Therm EL 14 • min. output 1500 W, rated output 13.5 kW, control step 1.5 kW
- suitable especially as a supplementary stable source for heating and hot-water preparation (hereinafter DHW) in combination with solar panels, a heat pump, etc., in passive houses or other buildings with lower heat loss
- built-in weather-compensation control
- smaller internal-tank dimensions - higher flexibility
- smaller external dimensions of the whole boiler - high installation-location variability
- smaller water volume, and therefore clearly:
- faster temperature rise
- more flexible and more precise control
- option to use a new control method
- new, clearer display method - texts, errors, fault messages...
- option to optionally connect the boiler to a single-phase or three-phase supply by simply linking the terminals!
- intuitive and easier control via a touch display, better menu orientation thanks to replacing abbreviations with full text)
- option of language versions - (Czech, Slovak, Russian, English, German)
- option to control the boiler via SMS messages and receive status information - optional (additional accessory available only for a standalone boiler)
- integrated topping-up (via a hydro-block), integrated bypass
- option to connect all boilers (regardless of type) into an intelligent cascade
- design finish in stainless-steel sheet
- integrated OPENTHERM communication - option to connect intelligent room controllers or, for example, a higher-level Siemens RVS control system...
- option to connect a room thermostat, etc.
| TECHNICAL DATA | unit | THERM EL 5 | THERM EL 9 | THERM EL 14 |
| Rated heat output | kW | 4,5 | 9 | 13,5 |
| Minimum heat output | kW | 0,5 | 1,0 | 1,5 |
| Minimum output control step | kW | 0,5 | 1,0 | 1,5 |
| Number of output control steps | - | 9 | ||
| Degree of electrical protection | - | 40 | ||
| Rated current – three-phase connection | A | 7 | 13 | 20 |
| Electrical voltage – three-phase connection | V/Hz | 3 x 400/230 + N + PE/50 | ||
| Maximum rated current – three-phase connection |
A | 3x8 | 3x14 | 3x21 |
| Main electrical circuit breaker – three-phase connection |
A | 10 | 16 | 24 |
| Rated current – single-phase connection | A | 21 | 40 | 60 |
| Electrical voltage – single-phase connection | V/Hz | 1 x 230 + N + PE/50 | ||
| Maximum rated current – single-phase connection | A | 1x24 | 1x42 | 1x63 |
| Main electrical circuit breaker – single-phase connection | A | 25 | 50 | 80 |
| Rated current of control fuse | A | 1,25 | ||
| Electrical service life of relay | - | 1.105 cycles (16 A, 250V/50 Hz) | ||
| Mechanical service life of relay | - | 10.106 cycles | ||
| Heating-water inlet - outlet | - | G 3/4“ external | ||
| Min. operating pressure of heating system | bar | 0,8 | ||
| Max. operating pressure of heating system | bar | 2,5 | ||
| Maximum heating-water temperature | oC | 80 | ||
| Boiler water volume | l | 6,0 | ||
| Efficiency at rated output | % | 99 | ||
| Expansion-vessel volume | l | 7 | ||
| Maximum number of boilers in cascade | ks | 32 | ||
| Dimensions (height/width/depth) | mm | 625/475/247 | ||
| Boiler weight without water | kg | 26,5 | ||
| Option to heat DHW in an external tank | - | yes | ||
Additional parameters
| Category: | Thermona THERM EL |
|---|---|
| Warranty: | 2 years |
| Product replaced by a new one:: | https://www.atria.sk/protherm-ray-6ke/ |
| The item has been sold out… | |