Note:The connection between the boiler and the tank is not included in the package.
VAILLANT VU 10CS/1-5 ecoTEC plus IoniDetect - wall-hung condensing boiler - output:2,9 - 10,9 kW (20 kW for domestic hot water)
We have made our best-selling boiler even better - using the latest technology that delivers a reliable heating solution for the future. Its excellent price-to-performance ratio makes it a genuinely good choice. Proven quality guarantees a long service life, while innovative features increase its efficiency. All of this contributes to a significant reduction in your costs.
Be ready for changes in gas composition
Thanks to the new IoniDetect combustion control technology, the boiler automatically detects fluctuations in gas composition, adapts to them, and always operates as efficiently as possible. This feature will be appreciated most of all in the future, as more environmentally friendly gas blends come into use.
Upgrade your system with renewable sources
The new ecoTEC plus offers a sustainable heating solution. Especially in combination with the sensoCOMFORT system controller, you can set up your heating system optimally - saving both energy and heating costs. Thanks to the new installation assistant, you can be sure your boiler will always run at maximum efficiency while giving you maximum comfort. For greater sustainability, you have the option of adding various flexible ways to expand the system with renewable energy sources: solar heating, heat pumps, or ventilation systems with heat recovery. Their shared eBUS communication language enables simple installation and control of the entire system.
It only takes a few steps to be able to control your new heating system from anywhere via an online app. All you need to do is add the sensoNET internet module to the boiler, which connects to your boiler on a plug-and-play basis (i.e. it works right after being connected), and download our free app. After that you can control it, for example, even on the way to your holiday. This option isn't just for your comfort. Since your heating runs at full power only when you actually need it, you save energy, cut your costs, and help the environment.
Convenient heating monitoring
Do you like being in control of your energy consumption? Especially in combination with the sensoCOMFORT system controller, you can control your boiler comprehensively and have detailed consumption data at your fingertips. Thanks to the new touch-enabled user interface, monitoring the boiler's operation becomes more convenient than ever before. Enjoy our modern design and user menu for intuitive, trouble-free operation.
How exactly do I choose the right output for a VAILLANT condensing boiler? The basis is the calculated heat loss of the heated building (most reliably taken from the project documentation or the energy certificate). If you don't have a project, you can estimate roughly 60-100 W per m² of floor area for a typically insulated house built after 2000, or 100-150 W/m² for an older, uninsulated house - the exact figure varies depending on the number of floors, ceiling height, the number and quality of windows, and the building's orientation. A boiler oversized for the required output switches on and off more often (so-called cycling), which shortens its service life and reduces efficiency; an undersized boiler, on the other hand, cannot heat the house sufficiently on frosty days.
Why is a condensing boiler more economical than a conventional one? A condensing boiler also makes use of the heat hidden in the water vapour produced when gas is burned - in a conventional boiler this vapour escapes unused through the flue, whereas in a condensing boiler it is cooled below the so-called dew point, the vapour condenses, and the released heat is returned to the heating circuit. As a result, condensing boilers achieve an efficiency of roughly 105-110% relative to the calorific value of the gas, compared with the usual 85-92% for conventional boilers.
What type of flue gas exhaust does this boiler need? Most modern condensing boilers are so-called turbo boilers (with a sealed combustion chamber) and require a concentric (coaxial) or separate flue gas exhaust and combustion air intake routed through an external wall or the roof - so a working chimney is not required. You will find the exact type and maximum exhaust length (for the 60/100 or 80/125 mm diameter) in the technical documentation for the specific model, or you can consult our customer service.
What does the ErP energy class stated for the boiler mean? This is a mandatory efficiency label for heating appliances under the EU ErP (Ecodesign) directive, similar to the energy labels on refrigerators. Condensing boilers commonly achieve class A, or higher when combined with room controls (e.g. A+ when used with weather-compensated control and a room thermostat).
Can I install and connect this boiler myself? No. Connection to the natural gas supply, the electrical network, and the flue gas exhaust is, by law, reserved exclusively for a person holding the relevant qualification (most often an authorised service technician for the given brand or a gas appliance inspection technician). After installation, the boiler must be commissioned by the manufacturer's authorised service, which is also usually a condition for the warranty to be valid.
What about servicing and the warranty? Most manufacturers require a regular annual service inspection by an authorised service centre for the warranty to remain valid even after its standard expiry (an extended warranty for regular servicing is common especially with the Vaillant, Protherm, and Viessmann brands). You will find the exact warranty terms in the warranty certificate supplied with the boiler.
What is included in the delivery of this specific product? The exact package contents (the boiler itself, and where applicable the domestic hot water tank, room controls, and other accessories in the case of a package) are stated in the product name and in its technical parameters above on this page.
Be the first who will post an article to this item!
5,0
The average product rating is 5,0 out of 5 stars.1 rating
5
1x
4
0x
3
0x
2
0x
1
0x
Leave a rating
List of ratings
Discussion
List of discussions
M
Miro
14/06/2022 16:51
Dobry den.
Prosim o zaslanie cenovej ponuky na kombinaciu VAILLANT VU 10CS/1-5 ECOTEC PLUS IONIDETECT + VIH R 120 A + ERELAX
Dakujem
RA
Radka ATRIA.SK
15/06/2022 14:57
Dobrý deň,
cena je ako je uvedené na stránke.
Pekný deň.
D
dominik
08/12/2021 11:37
Dobrý deň, vyberám izbový regulátor ku kotlu protherm leopard a zvažujem bezdrôdový buď Honeywell CM 727 alebo ten od Protermu za ca. 125 €. Chcem sa spýtať či sú oba kompatibilné s týmto kotlom príp. ktorý by ste mi odporučili. Taktiež sa chcem spýtať aký je dosah signálu, či to zvládne prenos aj cez 1 cca 20 cm stenu vzdialenú od kotla cca 15 m. Ďakujem
A
atria
08/12/2021 11:37
Dobrý deň. Obávam sa, že uvedený termostat Vám nebude správne komunikovať s kotlom. Odporučil by som Vám skôr termostatAVANSA 2007 TX https://www.atria.sk/avansa-2007-tx/ Pekný deň.
M
milan
08/12/2021 11:36
Chcem sa pitat v akom teplotnom rozmedzi zapina kotol teda pri akej teplote zapne a pri akej teplote vzpne termostat ked mam napr.nastavenu teplotu v izbe na 22 stupňov.ďakujem
A
atria
08/12/2021 11:36
Dobry den, to zalezi na nastaveni termostatu. Neviem zodpovedne povedaž, ze sa to da nastavit aj u tohto typu. Zvycajne sa kotol zapne, ked teplota klesne o pol stupna a stupne tiez o pol stupne na 22,5. Napriklad u tohto termostatu sa to da nastavit https://www.atria.sk/salus-eurotemp-091fl/
I
ivan
08/12/2021 11:35
dobrý..,, asi.. chcem si vymeniť starú CM707 za CM 727. Samozrejme preto lebo ju mam zle umiestnenú a neviem či možem s tým niečo urobiť, lebo kabel je zamurovaný v stene a trčí sotva 10 cm.. je umiestnený blízko krbu ato je zloba ako hrom,,lebo ked zakurim odstavý celú chalupu.. chcel som vyskušať to dať niekde inde.... čo vy na to.... a ozaj aký to má dosah,, lebo kotol je v pivnici .... dik moc,,, teda ak mi odpíšete...
A
atria
08/12/2021 11:36
Dobry den, tak na taku zlobu treba len bezdrotovy termostat. Bezdrotove termostaty maju dosah vo volnom priestore az sto metrov, takze doma v pohode dosiahnu do pivnice, pokial nebyvate mrakodrape v Dubaji... K dispozicií su aj niektore termostaty s podstavcom, nemusite ho zavesit na stenu, ale pouzit ho napriklad ako dekoraciu na nocny stolik.
I
ivan
08/12/2021 11:36
Pekny den a dakujem za odpoved. Mam este jednu dvojitu otazku: co ked uprostred treskucej zimy skoncia baterie - nevypne system na nudzovy rezim. Cca na 10 oC ??? Mam doma na stene CM 707 a otazka znie, ci sa to neda prerobit a dokupit zbytok a teda ci by to nebolo financne prijatelnejsie.???? Za vasu ochotu vam dakujem .
A
atria
08/12/2021 11:35
Ked vypadnu baterky, tak to uz potom bude zalezat na kotly, že ci obsahuje protimrazovu funkciu, ale kazdy moderny kotol už taketo nieco ma. Dalsia vec, prerobit sa to proste neda. Prijimac date do kotolne a napojite na kotol a termostat budete mat uz kde chcete. Osobne si myslim, že v klude si možete kupit lacnejsie termostat. Napriklad tento https://www.atria.sk/salus-t105rf-eurotemp-2100rf/ najpredavanejsi. S tym podstavcom.
I
ivan
08/12/2021 11:35
Dobry den, dakujem za pdpoved. Nie som kurenar a ako konzument sa chcem opytat, ze ked si kupim CM 727, ci si ju zapojim sam ako domaci kutil, alebo mam povolat odbornika.? Dalej vas poprosim o informaciu,, ten Salus 105, co ste mi spomenuli sko lacnejsiu alternativu. Sa tiez da nastavit tak ze meni teploty ako CM727?,,, napriklad: doobeda mi staci , 20.•C , - a poobede 22•C a v noci tiez menej 20,5 a rano ked idu deti do skoly tak od 05.hod kurim na 23 •C., A este co je to u toho salusa ked pisu menit dve teploty s moznostou nastavenia.... Som otravny,, prepacte,, ale nechcem kupit dalsi regulator a hodit ho potom do kosa... Dakujem za trpezlivost a za odpoved
A
atria
08/12/2021 11:35
Bry den, ked si kupite termostat je velmi jedhoduche ho zapojit, v podstate ten primac date do kotolne a vodice, ci kable zapojite namiesto tych starych, co tam boli a co viedli hore k tomu krbu. Len asi bude treba odnat niaky kryt na tom kotly. NO ale ked citam, že chcete viace krat zmenit teplotu za den, tak v tom pripade tam nemože ist ten povodny salus co som Vam napisal ale iba tento https://www.atria.sk/salus-eurotemp-2026tx/ . Tento može viacej krat zmenit teplotu aj za den. Primac vopchate do zasuvky do kotolne, z neho trci kabel, ktory teda napojite namiesto tych povodnych kablov. Priechodzia zasuvka je len vyhoda navyše.
M
marek
08/12/2021 11:34
Zdravim je vas termostat CM727 vhodny na Wiessmann vitopend 111? dakujem
A
atria
08/12/2021 11:35
Dobrý deň, kotol Vitopend je riadený obyčajným spínacím kontaktom, takže tento termostat môžete použiť. Je to presný a spoľahlivý termostat s jednoduchou obsluhou.
S
stano
08/12/2021 11:34
Dobrý deň, je CM727 vhodný na kotol Protherm Panther 25KTO? Je v balení / manuáli/ návod na zapojenie alebo musím zavolať odborníka. Vopred ďakujem.
A
atria
08/12/2021 11:34
Dobrý deň, honeywell Vám nebude fungovať, musí tam byť regulátor ktorý komunikuje cez eBus, takže protherm thermolink https://www.atria.sk/protherm-thermolink-p/.Pekný deň.
J
jano
08/12/2021 11:34
dobry den, chcel by som sa informovat, ci nie je problem s montazou bezdrotoveho termostatuHoneywell ku kotlu Junkers rady Eurostar.
A
atria
08/12/2021 11:34
Dobrý deň, pri kotle Eurostar myslím že montáž bude veľmi jednoduchá. Pekný deň.
B
brano
08/12/2021 11:33
Viete zabezpecit aj montaz tohoto termostatu v Bratislave? Co by to stalo?
A
atria
08/12/2021 11:33
Sme len internetový predaj, žiaľ montáž nevykonávame. Pekný de§ňň
K
kata
08/12/2021 11:33
Dobrý večer, chcem sa opýtať, že: máme nastavenú teplotu na 23 st. až do 22hod., no termostat ukazuje len 21,5 st. a keď sa pozriem na kotol, tak nezohrieva (nepracuje- nie je tam plamienok) Kotol máme nový kondenzačný, určite v ňom chyba nie je. Ale prečo potom termostatHoneywell CM 727 ak zmeria teplotu v byte na 21,5st., tak by mal zohriať kotol na nami nastavenú teplotu - na tých 23st., nie? a ono to nič nerobí, stá.le je len tých 21,5 prípadne 22,O st.
A
atria
08/12/2021 11:33
Dobrý deň, tak ak máte nový kondenzačný kotol, vôbec nemusí tento termostat s ním komunikovať. Napíšte presný typ a potom budeme vedieť kde je chyba.
P
peter
08/12/2021 11:32
Dobrý večer. Ktorý z ponúkaných PRENOSNÝCH termostatov je možné pripojiť ku kondenzačnému kotluViessmann VITODENTS 100?? Teraz fungujeme na statickom izbovom Viessmann.Za skorú odpoveď ďakujem.
A
atria
08/12/2021 11:32
Dobrý deň, k rade 100 sa dá pripojiť každý prenosný dvojbodový termostat, najviac sa však predáva tento https://www.atria.sk/salus-eurotemp-091flrf/. Pekný deň.
V
vlado
08/12/2021 11:32
Prosím vas je možné pripojiť bezdrotovy termostat cm727 ku plynovemu kondenzacnemu kotlu Buderus Logamax plus GB072-14?? Ďakujem
A
atria
08/12/2021 11:32
Dobrý deň, ku buderusu nebude fungovať tento dvojbodový termostat, treba použiť originál buderusregulátor https://www.atria.sk/buderus-logamatic-rc-35/. Pekný deň.
P
peter
08/12/2021 11:31
Dobry den, mam kotol Protherm LEV 24 KKV, ale nema eBus. Je mozne tento termostat pripojit aj k tomuto kotlu ? Dakujem
A
atria
08/12/2021 11:32
Pokiaľ kotol nemá ebus, tak v tom prípade termostat pôjde použiť. Pekný deň
N
noris
08/12/2021 11:31
Dobrý deň.Chcel by som sa spýtať či je možné pripojiť Honeywel CM 727 ku kondenzačnému kotluJunkers CerapurSmart ZWB 24-3C.Mám teraz ani nie ročnýSalus T105RF a reguluje si ako chce.Mám nastavenú teplotu na 22 C/v miestnosti je 23,5 C/-izbová prenosná jednotka nedáva pokyn na vykurovanie a releova jednotka je zopnutá a pec kúri aj na 28 C.Ďakujem za odpoveď.
A
atria
08/12/2021 11:31
Dobrý deň, ku kotlu Junkers ZWV potrebujete modulačný termostat, salus ani honeywell fungovať nikdy nebude kedžé sú to obyčajné dvojbodové termostaty. V návode na inštaláciu si nájdete zapojenie https://www.atria.sk/junkers-cerapursmart-zwb-24-3-c/#files. Pekný deň.
R
rado
08/12/2021 11:30
Dobrý den. Prosim Vas o radu. Mam kotol Vitopend 100 a termostatHoneywell 727rf. Zapojil som ho podla schemy. Z prijímaca Honeywell-u idu kontakt A a B. KOtol Má na konektore 96 kontakty 1, L, N a uzemnenie. Kntakt A som spojil v prijímaci s kontaktom L (fázu) a z kontaktu B na prijímaci som isiel na kontakt 1 na konektore 96. Zapojenie mi funguje. Mam ale obavy ci je to zapojene spravne. Lebo pred montázou boli kontakty 1 a L na konektore 96 spojene. Neviem teda ci rele rozopina spravny kontakt. Preluskal som uz hodiny na nete a nic konkretne. Za vasu odpoved DAKUJEM.
A
atria
08/12/2021 11:31
Dobrý deň, tak najviac sa predáva tento najjednoduchší. Pri dekoltovaní dymu spustí hlasitý poplach. https://www.atria.sk/detektor-dymu-jablotron-sd-728/
M
marian
08/12/2021 11:30
Dobry den, zhanam regulaciu na 3 vacsie plynove lampy vo vyrobnej hale. Stara regulacia mi zhorela a uz sa nevyraba. Potreboval by som nieco ako 2 stupnovu regulaciu. T.j. ked mi teplota klesne pod zadanu teplotu potreboval by som aby regulacia najskor zapalila "vecne svetlo" a par sekund po nahriati aby pustila plyn. Nevedeli by ste mi ponuknut nejaky vhodny produkt?
A
atria
08/12/2021 11:30
Dobrý deň, V takomto prípade reguláciu nemáme. Jedine použiť dve a nastaviť ich na rozdielne teploty. Pekný deň.
L
ladislav
08/12/2021 11:29
Dobrý deň, momentálne mám nainštalovaný termostat CM 707 - bohužiaľ pri krbe, takže sa vypína. Chcem sa opýtať či je možné ho vymeniť za bezdrôtový CM 727 a či je tam jednoduchá montáž (montážny list v balení) a či by bol kompatibilný s kotlom Junkers ZSBR 28 - 3A23 S7323. Za vašu odpoveď vopred ďakujem.
A
atria
08/12/2021 11:30
Dobrý deň, Ak Vám s daným kotlom funguje CM 707 bude Vám fungovať aj CM 727. Montáž je tam tá istá, tie isté svorky. Prajem pekný zvyšok dňa.
J
julo
08/12/2021 11:30
Dobry den, mam kotol Buderus Logamax U052 (24kw) a momentalne mam termostat CM 707, tiez by som ho chcel vymenit za CM 727 ale techink priamo na centrale v buderuse mi povedal, ze na tento moj kotol neexistuje "bezdrotovy" termostat. som teraz trosku z toho zmateny. Bude mi teda fungovat aj 727? zo steny mi trcia iba 2 droty (L hnedy a N modry). Dakume za odpoved.
A
atria
08/12/2021 11:29
Dobrý deň, ak ste pôvodne mali termostatHoneywell, tak Vám bude fungovať aj bezdrôtový termostat. Ten servisný technik sa pravdepodobne pomýlil.
M
marek
08/12/2021 11:29
Dobry den, rozhodujem sa o vybere bezdrotoveho termostatu pre buderus logamax u052t, ktory z vasej ponuky by bol vhodny? Rad by som vedel nastavit rezimy podobnym sposobom ako na rc35, dakujem
A
atria
08/12/2021 11:29
Dobrý deň. Odporúčame originálny termostat od firmy Buderus, ale momentálne Buderus nepredávame. S pozdravom
M
marek
08/12/2021 11:29
Dobry den, rozhodujem sa o vybere bezdrotoveho termostatu pre buderus logamax u052t, ktory z vasej ponuky by bol vhodny? Rad by som vedel nastavit rezimy podobnym sposobom ako na rc35, dakujem
D
dusan
08/12/2021 11:28
Môžem použiť bezdrôtový termostat CM 727 A na kotol Junkers CerapurSmart ZWB 24-3?
A
atria
08/12/2021 11:28
Dobrý deň, nie, Vami zvolený termostatnie je vhodná voľba ku kotlu Junkers CerapurSmart ZWB 24-3. Na našej stránke nájdete tabuľku použiteľnosti na nasledujúcej adrese: https://www.atria.sk/vykurovacia-technika/izbove-termostaty-a-regulacie/originalne-regulacie-ku-kotlom/regulacie-junkers/ Vašim potrebám by mal vyhovať termostat Junkers FW 120, ktoý nájdete tu: https://www.atria.sk/junkers-fw-120/
L
lubica
08/12/2021 11:28
Dobrý deň. Mám termostatHoneywell CM 727. Mám ho však v obývačke, kde často kúrim v kachľovej peci a termostat sa vypína. Môžem ho vyniesť na poschodie, napríklad do spálne? Bude komunikovať s kotlom aj na takú diaľku a za zatvorenými dverami? Ďakujem za odpoveď.
A
atria
08/12/2021 11:28
Dobrý deň, áno môžete, nemal by sa objaviť žiaden problém v komunikácii kotla a termostatu.
Listing controls
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.