Avansa 110 R
Code: AVANSA 110RProduct detailed description
Avansa 110 R, thermostat for pumps and boiler rooms
The AVANSA 110-R thermostat is a dual-function device - it is designed for the independent control of two pumps.
How the heating pump works
The thermostat's task is to switch the pump on when the temperature exceeds the set value and switch the pump off when the boiler cools down. This prevents excessive pump operation, which saves electricity (depending on boiler usage, savings of up to 60% are possible) and extends the pump's service life.
How pump II works
With the AVANSA 110-R thermostat, we have the ability to control the switch-on and switch-off temperature of the pump. The pump switches on once the user-set switch-on temperature is exceeded, and switches off once the set switch-off temperature is exceeded.
Technical data:
- Supply voltage: 230V 50Hz ±10%
- Ambient temperature: -10...+50 °C
- Switching current: 6A
- Temperature measuring range: 0...90 °C
- Pump temperature setting: 5...80 °C
- Pump II temperature setting: 10...80 °C
- Maximum sensor temperature: -10...120 °C
Frequently Asked Questions
- How exactly does a manual (simple) thermostat work? It measures the temperature at its installation location and, when it drops below the set value, closes a contact that starts the heat source (boiler, pump, heating element) - once the set temperature is reached, the contact opens again. Unlike programmable thermostats, it has no weekly or daily program; the temperature is set manually using a rotary or sliding control.
- Where should the thermostat be placed? In a location that best represents the normal room temperature - away from direct sunlight, draughts, radiators or other heat/cold sources that could distort the measurement.
- Must installation be carried out by an electrician? Connecting the thermostat to the electrical circuit of the heat source should be carried out by a person with electrotechnical qualification, since it involves work on the electrical installation and load switching.
Additional parameters
| Category: | pump and boiler room thermostats |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.15 kg |
| Measuring range of temperature: | 0...90 °C |
| Maximum sensor temperature: | -10...120 °C |
| Pump temperature settings: | 5...80 °C |
| Pump temperature settings II: | 10...80 °C |
| Supply voltage: | 230V 50Hz ±10% |
| Switching Current: | 6A |
| Teplota okolia: | -10...+50 °C |