Stiebel Eltron PSH 150 WE-R - right
Code: 236235Related products
Product detailed description
Stiebel Eltron PSH 150 WE-R
- replacement for Tatramat OVK 150 P
- combination vertical wall-mounted water heater with a 0.6 m2 tube heat exchanger - right
- volume:150 liters
- power: 2 kW
The product range PSH R is made up of tank-type wall-mounted combination water heaters in a round design. They are unique for their quality, design created by top designers, and their operating characteristics.
The water can be heated using an all-stainless-steel heating element and tube heat exchanger.
PSH R heaters are manufactured for heat exchanger connection on the right side. The installation must include a central heating pump, which is not included in the delivery.
Easy installation, control and maintenance
- universal bracket
- ergonomically shaped handles
- option to install above a bathtub
- separate pocket for an external heat source sensor
- external setting of the optimal heating temperature via the operating thermostat
Multi-stage protection
- safety thermostat
- fuse against water freezing
- fuse against heater overheating with reset function
- safety valve with non-return valve as an accessory
- protection rating IP25
Long service life
- stainless steel flange with a stainless steel heating element
- special enamel CoPro – double-sided enamelling
- anode corrosion protection
User comfort
- high volume of mixed hot water
- short heating times
- visual check of water temperature
- option to connect to a circulation line
Efficiency and low energy consumption
- 48 mm thermal polyurethane insulation
Description and dimensions
DescriptionDimensions| Description | Dimensions |
| 1. Outlet pipe | A = 1 410 mm |
| 2. Outlet pipe | B = 1 064 mm |
| 3. Circulation | C = 346 mm |
| 4. Heating element | D = 907 mm |
| 5. Anode | E = universal bracket (accessory) |
| 6. Temperature indicator | |
| 7. Rotary temperature control | |
| 8. Universal bracket (accessory) | |
| 9. Heating water inlet | |
| 10. Heating water outlet |
| Parameters | PSH 150 WE-R | |||
|---|---|---|---|---|
| Rated capacity (l) | 151 | |||
| Electrical connection | 1/N/PE ~ 230 V | |||
| Max. operating pressure (MPa) | 0,6 | |||
| Max. operating pressure in the heat exchanger (MPa) | 0,6 | |||
| Power input (kW) | 2 | |||
| Heat losses (kWh/24h) | 1,426 | |||
| Amount of 40 °C mixed water (l) | 278 | |||
| Electric heating time from 15°C to 65°C with 2 kW output (min) | 240 | |||
| Active heat exchanger surface (m2) | 0,6 | |||
| Heat exchanger output (kW) | 11,1 | |||
| Heating time from 15 °C to 65 °C with the heat exchanger (min) | 39,2 | |||
| Weight without water (kg) | 55,2 | |||
| Weight filled with water (kg) | 203,2 | |||
| PU insulation thickness (mm) | 48 | |||
| Electrical protection rating | IP 25 | |||
| Energy efficiency class | C | |||
| øxH (cm) | 51 x 139,2 | |||
Frequently Asked Questions
- What tank capacity should I choose? A common consumption estimate is based on approx. 40-50 liters of hot water (at approx. 40-45 °C) per person per day for standard use (showering, washing); if bathing in a tub or with more bathrooms/outlets, plan for a higher volume. When choosing, also consider whether the tank will be heated by a high-output boiler (faster heating, a smaller volume may be enough) or, for example, only by a solar system (where a larger volume is instead worthwhile for storing heat accumulated during the day).
- Can I connect this TATRAMAT tank to my existing boiler? In most cases yes, but you should check the compatibility of the hydraulic connection (dimensions and type of fittings) and whether your boiler supports controlling the tank's heating (a temperature sensor in the tank and possibly a diverter valve are needed) - you will find these details in the product's technical parameters, or our customer service can advise you.
- Where and how is the tank installed? The tank is installed as close as possible to the heat source (boiler) to minimize heat losses in the connecting pipework, while still leaving enough space around it for service access (anode replacement, safety valve inspection).
- Does the installation have to be carried out by a professional? We always recommend entrusting the hydraulic connection to the water supply and the heat source, including fitting a safety valve set to the correct pressure, to a heating engineer/installer - an incorrectly fitted or missing safety valve is a safety hazard.
Additional parameters
| Category: | Vertical |
|---|---|
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
M
Martin
Dobrý den, je možné ešte tento produkt objednat?
A
ATRIA.SK
Dobrý deň,
nie u nás už nie je dostupný. Pekný deň.