Stiebel Eltron PSH 80 WE-R - right
Code: 236231Related products
Protherm Panther Condens 25 KKO - 2021 model- wall-hung condensing boiler with the...
Avansa 2007 - programmable weekly thermostat The Avansa 2007 room...
Avansa AUTO 25/6/180 Circulation Pump The Avansa AUTO 25/60 180mm circulation...
Magnetic dirt separator for vertical and horizontal pipework CALEFFI DIRTMAG®...
Screw coupling 16x16 with screw union requires no pressing, for use with...
Product detailed description
- universal bracket
- ergonomically shaped handles
- option to install above a bathtub
- separate pocket for an external heat source sensor
- external setting of the optimal heating temperature via the operating thermostat
- safety thermostat
- fuse against water freezing
- fuse against heater overheating with reset function
- safety valve with non-return valve as an accessory
- protection rating IP25
- stainless steel flange with a stainless steel heating element
- special enamel CoPro – double-sided enamelling
- anode corrosion protection
- high volume of mixed hot water
- short heating times
- visual check of water temperature
- option to connect to a circulation line
- 48 mm thermal polyurethane insulation
DescriptionDimensions| Description | Dimensions |
| 1. Outlet pipe | A = 871 mm |
| 2. Outlet pipe | B = 523 mm |
| 3. Circulation | C = 348 mm |
| 4. Heating element | D = 660 mm |
| 5. Anode | E = universal bracket (accessory) |
| 6. Temperature indicator | |
| 7. Rotary temperature control | |
| 8. Universal bracket (accessory) | |
| 9. Heating water inlet | |
| 10. Heating water outlet |
| Parameters | PSH 80 WE-R | |||
|---|---|---|---|---|
| Rated capacity (l) | 79 | |||
| Electrical connection | 1/N/PE ~ 230 V | |||
| Max. operating pressure (MPa) | 0,6 | |||
| Max. operating pressure in the heat exchanger (MPa) | 0,6 | |||
| Power input (kW) | 2 | |||
| Heat losses (kWh/24h) | 0,89 | |||
| Amount of 40 °C mixed water (l) | 128 | |||
| Electric heating time from 15 °C to 65 °C with 2 kW output (min) | 128 | |||
| Active heat exchanger surface (m2) | 0,6 | |||
| Heat exchanger output (kW) | 10,3 | |||
| Heating time from 15 °C to 65 °C with the heat exchanger (min) | 18 | |||
| Weight without water (kg) | 37,2 | |||
| Weight filled with water (kg) | 113,3 | |||
| PU insulation thickness (mm) | 48 | |||
| Electrical protection rating | IP 25 | |||
| Energy efficiency class | B | |||
| øxH (cm) | 51 x 85,3 | |||
Frequently Asked Questions
- What tank capacity should I choose? A common consumption estimate is based on approx. 40-50 liters of hot water (at approx. 40-45 °C) per person per day for standard use (showering, washing); if bathing in a tub or with more bathrooms/outlets, plan for a higher volume. When choosing, also consider whether the tank will be heated by a high-output boiler (faster heating, a smaller volume may be enough) or, for example, only by a solar system (where a larger volume is instead worthwhile for storing heat accumulated during the day).
- Can I connect this TATRAMAT tank to my existing boiler? In most cases yes, but you should check the compatibility of the hydraulic connection (dimensions and type of fittings) and whether your boiler supports controlling the tank's heating (a temperature sensor in the tank and possibly a diverter valve are needed) - you will find these details in the product's technical parameters, or our customer service can advise you.
- Where and how is the tank installed? The tank is installed as close as possible to the heat source (boiler) to minimize heat losses in the connecting pipework, while still leaving enough space around it for service access (anode replacement, safety valve inspection).
- Does the installation have to be carried out by a professional? We always recommend entrusting the hydraulic connection to the water supply and the heat source, including fitting a safety valve set to the correct pressure, to a heating engineer/installer - an incorrectly fitted or missing safety valve is a safety hazard.
Additional parameters
| Category: | Vertical |
|---|---|
| Warranty: | 2 years |
| Weight: | 33 kg |
Avansa 2007 - programmable weekly thermostat The Avansa 2007 room...
Clamp-on thermostat AVANSA TH 2A for circulation pump used to...
The ADEX TTUV electronic thermostat consists of the TTUV1 control module, the...
Euroster 11 E, thermostat for pump (central heating or DHW) Programmable...
Avansa AUTO 25/6/180 Circulation Pump The Avansa AUTO 25/60 180mm circulation...
Brass manifold for underfloor heating, 6-way, 1" connection.Number of circuits:...
Protherm Gepard Condens 25 MKO- wall-hung condensing boiler with the option to...
Large Thermostatic Head - Varnished size: M30 x 1.5,control range: +6°C...
Two-way regulating thermostatic valve - 1/2"xEK; angle
Tesnenie threads ALPEX-GAS, IVAR.LOCTITE 55, balenie: 160 m,...
Brass threaded reducer 1/2" x 1/4" MF is the most commonly used...
Pipe insulation 18 mm (3/8") / 9mm Pipe insulation, or insulating foam for...
-
(615 kB) Technical Data Sheet
-
(11,04 MB) Instructions for Use
-
(61 kB) Energy Label and Data Sheet
-
(89 kB) Declaration of Conformity
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!