Vaillant flue extension 2.0 m Ø 110 mm PP
Code: 0020106386Product detailed description
Vaillant flue extension 2.0 m, Ø 110 mm
The flue extension with a length of 2.0 metres is the longest straight section in the range of original Vaillant Ø 110 mm shaft system components. Where the shorter 0.5 m and 1.0 m extensions allow fine-tuning of the assembly height to the centimetre, this 2-metre piece serves primarily for quickly and economically covering long straight shaft sections – typically in multi-storey apartment buildings or tall masonry chimneys of family houses, where assembling from shorter pieces would mean unnecessarily many joints.
Vaillant LAS Ø 110 mm shaft flue gas discharge system
This part is part of the original Vaillant shaft flue gas discharge system (abbreviated LAS – from the German "Luft-Abgas-System"), which is used with high-output condensing boilers (typically higher output ranges of ecoTEC exclusiv/pro/plus and floor-standing ecoCRAFT exclusiv boilers, as well as equivalent-output Protherm models from the same manufacturing group). Unlike a standard concentric flue (pipe within a pipe) used with small wall-mounted boilers, the shaft system routes flue gases through a single-wall pipe with a diameter of 110 mm inside an existing building chimney shaft (most often an older masonry chimney no longer used for its original purpose), while combustion air is drawn in through the free space of the shaft around this pipe.
The advantage of this solution is that it does not require any new penetration through the facade or roof in addition to the existing shaft, and in multi-storey buildings it allows routing the discharge to the required height without the need to build a new chimney. All system parts are made of durable polypropylene (PP), which withstands long-term contact with the mildly acidic condensate produced during condensing boiler operation, and are joined using a simple socket-to-socket push-fit system with an integrated sealing ring, without the need for gluing or additional sealing.
Why choose the 2-metre piece
Every push-fit joint in the flue is also a potential point requiring attention during installation to ensure correct insertion and orientation of the sealing ring. When the discharge runs through three, four or more storeys of a shaft, it therefore makes sense to use as few but as long pieces as possible – this reduces the number of joints, shortens installation time and reduces the overall risk of leakage over decades of operation. A 2.0 m piece allows a single piece to span, for example, the height of two typical storeys, with the remaining difference to the exact height then resolved by combining it with a shorter 0.5 m or 1.0 m extension from the rest of the range.
The pipe is made of polypropylene (PP) resistant to condensing boiler flue gas condensate (mildly acidic environment, pH approximately 3–5), with a smooth internal surface minimising pressure losses over the long run and ensuring smooth condensate flow back towards the boiler or to a collection point at the base of the shaft.
Installation into the assembly
The extension is inserted socket-end first into the spigot (smooth end) of the adjacent part – joint tightness is ensured by an integrated rubber sealing ring, which we recommend lightly coating with silicone lubricant intended for plastic piping systems before insertion (this eases insertion and extends the seal's service life). Given the 2 m length, when working in a vertical shaft it is advisable to have a second person or suitable lifting/guiding aids available so that the piece does not bend or get scratched against the shaft walls during insertion.
When installing a long straight section, do not forget a sufficient number of spacer brackets, which centre the pipe within the cross-section of the shaft (typically approximately every 2 metres, exact spacing can be found in the boiler's installation manual), and fixing clamps, which secure the entire column against lateral movement without preventing its free thermal expansion.
Step-by-step installation procedure
- Before installation, based on the boiler's installation manual and the actual shaft height, prepare an exact list of parts (number and lengths of extensions, bends, inspection pieces) so that the sum of lengths matches the actual route height.
- Check that the spigot end of the extension and the socket end of the adjacent part are clean, free of mechanical damage and free of deposits from transport.
- Lightly coat the sealing ring in the socket with silicone lubricant intended for plastic piping systems.
- Carefully insert the piece into the socket of the previous section of the assembly all the way to the stop, with two people handling it in a vertical shaft due to the 2 m length.
- Verify that the piece is inserted evenly (without skewing), and continue by connecting the next section of the assembly (bend, further extension, or inspection piece) according to the route design.
- Install spacer brackets and fixing clamps at appropriate intervals according to the boiler's installation manual.
- After completing the entire assembly, carry out a visual inspection of all joints and have the handover of the system confirmed by a chimney sweep or inspection technician before first starting the boiler.
Practical example
When replacing an older atmospheric boiler with a high-output condensing boiler in an apartment building with 4 above-ground storeys, the original masonry chimney with an internal cross-section of approximately 30 × 30 cm was used as a protective shaft for the new plastic Ø 110 mm flue. To span a height of approximately 11 metres from the boiler room in the basement to the termination above the roof, four 2-metre extensions were used (8 m total), supplemented by one 2 m and one 1 m piece from the rest of the range for exact adjustment, together with a support bend at the base and an inspection bend at mid-height of the shaft. Thanks to the predominant use of 2-metre pieces instead of a larger number of shorter sections, the number of push-fit joints along the entire route was reduced by approximately a third compared to a solution made up solely of 0.5 m and 1.0 m pieces.
How to decide between 0.5 / 1.0 / 2.0 m lengths
When compiling a bill of materials for a specific installation, we recommend proceeding from the total measured route height downward: first divide the height into as many 2-metre pieces as possible, then adjust the remaining difference to the exact height using a combination of 1.0 m and 0.5 m pieces (or by cutting the last piece to size with a hand saw). This procedure minimises the number of push-fit joints while maintaining the exact assembly height. When ordering, also take into account the length "consumed" by bends and inspection pieces included in the route – do not count these towards the total straight length twice, as their own overall length is part of the given part's specification. If in doubt about the exact number of pieces, it is always worth having the assembly calculated by an installation company or our customer service before ordering, to avoid having to purchase additional individual pieces after installation has begun.
Typical usage scenarios
You will most often reach for this part when:
- installing a new high-output condensing boiler in an apartment building with a tall, originally masonry chimney shaft,
- replacing an older atmospheric boiler with a condensing one, where the original chimney stops being used for direct discharge and becomes merely a protective casing for the new plastic flue,
- extending or supplementing an existing assembly during a boiler room renovation on a higher floor.
By combining several 2-metre pieces (possibly supplemented with shorter pieces for fine adjustment), it is possible to assemble a discharge for almost any real shaft height common in residential construction.
Compatibility and use within the system
This part belongs to the closed range of original Vaillant accessories for Ø 110 mm shaft flue gas discharge and is intended for combination with other parts of the same range – extensions (0.5 m, 1.0 m and 2.0 m), bends of various angles, inspection pieces, support bends, spacer brackets, fixing clamps and a wall rosette. It is used primarily when installing or replacing high-output Vaillant condensing boilers (ecoTEC exclusiv range, ecoTEC pro/plus in higher output versions, and floor-standing ecoCRAFT exclusiv boilers), as well as corresponding Protherm models (Panther Condens, Tiger Condens, Bizon Condens in higher outputs) – Vaillant and Protherm belong to the same manufacturing group, so parts of the discharge system are commonly identical, however always verify the exact type and connection dimension in the installation manual for your specific boiler.
Before ordering, we recommend having a simple assembly design prepared by our customer service or an installation company according to the height and diameter of your existing shaft – the correct number and combination of parts (length of straight sections, number and angle of bends, number of spacer brackets and fixing clamps) is key to the safe and standard-compliant operation of the entire discharge system.
Shaft flue gas discharge systems of this type are designed and assessed in both Slovakia and the Czech Republic according to the STN EN 1443 (Chimneys – General requirements) and STN EN 14471 (Chimneys – System chimneys with plastic flue liners) standards, which among other things define the designation of the so-called temperature, pressure and resistance classes of components (for example, condensate resistance class "W" – wet operation, typical precisely for condensing boilers). Original Vaillant parts of this range correspond to the relevant classes stated in the manufacturer's documentation and installation manual of the specific boiler with which the system is supplied – this compliance is precisely the reason why it is recommended to use only parts from one closed range for shaft discharge, rather than combining them with products from other manufacturers.
Comparison with shorter extensions in the range
The range of Ø 110 mm straight sections offers three lengths – 0.5 m, 1.0 m and this 2.0 m piece. The shorter pieces (0.5 m and 1.0 m) are suitable for fine adjustment of the assembly to an exact height or for short sections between two bends, while the 2.0 m piece is intended for quickly spanning long straight passages with a minimum of joints. In practice, all three lengths are commonly combined in a single assembly – the longer pieces form the main backbone of the route, while the shorter ones are used to fine-tune the remaining height.
Technical parameters
| Brand | Vaillant |
|---|---|
| Part type | Flue extension |
| Diameter | 110 mm (single-wall) |
| Length | 2.0 m |
| Material | Polypropylene (PP) |
| System type | Shaft (LAS) |
| Joint | Push-fit, rubber sealing ring |
| Intended for | ecoTEC exclusiv/pro/plus (higher output), ecoCRAFT exclusiv |
| Compatibility | Protherm (same manufacturing group) – verify in manual |
| Suitable for shaft | masonry/existing building shaft |
| Supplier | WINTNER s.r.o. |
| Warranty | 2 years |
Maintenance and service inspections
A shaft flue gas discharge made of polypropylene requires little maintenance, but as part of the flue gas path it is subject, just like a masonry chimney, to regular inspection by a chimney sweep according to applicable regulations and intervals set by the boiler manufacturer and local chimney inspection regulations. During inspection, the main things checked are joint tightness, pipe patency (deposits, possible foreign objects), the condition of the sealing rings in the push-fit joints, and the functionality of condensate drainage from the lower part of the system. PP parts are not normally cleaned with aggressive solvents – mechanical removal of deposits and rinsing with water, or a mild detergent, is sufficient.
Condensate produced during condensing boiler operation is mildly acidic (typically in the range of pH approximately 3 to 5, depending on the type of gas burned and the boiler's operating state), which is why the entire system route is designed with a gradient towards the collection point, with condensate being drained either directly into the boiler (where it is usually neutralised or discharged into the sewer via a siphon), or into a separate collection point at the base of the shaft. During regular inspection, therefore, also pay attention to whether the condensate is actually flowing freely and not standing at lower points of the route, which could indicate an incorrect slope or a blockage in some section.
Safety and regulatory notes
A shaft flue gas discharge is subject to the same regulations regarding inspection and cleaning of chimney structures as a classic masonry chimney, since the shaft itself continues to serve as a protective casing around the plastic pipe and as a space for drawing in combustion air. Before commissioning, have the assembly inspected by an authorised chimney sweep and entrust the installation to a company with professional competence for installing gas appliances and flue gas paths.
Why choose the original part
Original Vaillant parts are made of exactly the same material and with the same tolerance dimensions as the boiler's original assembly, guaranteeing 100% compatibility with the rest of the system and preserving the manufacturer's warranty on the flue gas path. With non-original or universal parts, there is a risk not only of problems with the tightness of the push-fit joint, but potentially also issues with warranty recognition or acceptance by a chimney sweep during inspection.
Frequently asked questions
Can the 2-metre extension be cut to size?
Yes, the PP pipe can be cut to the required length with a fine metal or plastic saw – the cut needs to be squared and deburred so that the insertion end can be joined to the adjacent part without problems.
How many spacer brackets do I need for a 2-metre section?
The exact spacing is determined by the specific boiler's installation manual, but in practice one bracket per approximately every 2 metres of length is commonly used, with tighter spacing for longer or more heavily loaded sections.
Can I combine the 2 m extension with 0.5 m and 1.0 m pieces from the same range?
Yes, all lengths in the Ø 110 mm range have the same push-fit system and can be freely combined when assembling an exact assembly height.
Does the extension need to be additionally sealed with silicone?
No, the joint is tight thanks to the integrated rubber sealing ring; additional sealing is not necessary and could make any future disassembly more difficult.
Will this part withstand higher flue gas temperatures during a boiler fault condition?
The parts in this range are dimensioned for the normal operating temperatures of condensing boilers; exact temperature classes can be found in the manufacturer's technical data sheet. If you suspect long-term boiler overheating, address the underlying cause with a service technician first.
Is the part sold individually or only as a package?
It is sold as an individual piece, so you can order exactly as many 2-metre extensions as your specific assembly requires.
Is it necessary to measure the actual shaft height before installation, or is an estimate based on the drawing sufficient?
We recommend always measuring the actual height directly on site, as real building dimensions may differ slightly from the original design documentation.
Can the installation be carried out by the user themselves?
We recommend entrusting installation of the flue gas path to a condensing boiler to a professionally competent installation company, which will also ensure correct commissioning and handover of the boiler, including the necessary documentation.
What should I do if the route length does not exactly match the sum of available parts?
The PP pipe can be cut on site with a saw to the required length, or supplemented with a combination of pieces of other lengths from the same range.
Are additional inspections of this part needed during boiler operation?
The part is part of the flue gas path and is subject to the same regime of regular chimney sweep inspections as the rest of the assembly; it does not require a separate additional inspection.
Can this part be ordered in larger quantities at once for multiple apartments in a building?
Yes, when carrying out a project for multiple housing units or multiple boiler rooms in one building, the required number of pieces can be ordered at once, with the same price and delivery conditions.
Is the colour of the pipe always the same, or does it vary by production batch?
Parts in this range are usually supplied in a uniform greyish/natural shade typical of this type of polypropylene; minor shade variations between production batches are possible but have no effect on function or appearance once installed in the shaft.
Additional parameters
| Category: | Vaillant |
|---|---|
| Warranty: | 2 years |
| Brand: | Vaillant |
| Part type: | Flue extension |
| Diameter: | 110 mm (single-wall) |
| Length: | 2.0 m |
| Material: | Polypropylene (PP) |
| System type: | Shaft (LAS) |
| Joint: | Push-fit, rubber sealing ring |
| Intended for: | ecoTEC exclusiv/pro/plus (higher output), ecoCRAFT exclusiv |
| Compatibility: | Protherm (same manufacturing group) – verify in manual |
| Suitable for shaft: | masonry/existing building shaft |
| Supplier: | WINTNER s.r.o. |
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
O spoločnosti
Skupina Vaillant Group je synonymom vykurovania a prípravy teplej vody, pričom hlavný dôraz kladie na kvalitu, spoľahlivosť a užívateľský komfort. Jej produkty tepelnej techniky sú zastúpené vo viac ako 100 krajinách sveta. Združuje značky Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval a Protherm. Každá z týchto značiek má s výrobou vykurovacích zariadení bohaté skúsenosti, pretože väčšina z nich je v danom segmente viac ako 80 rokov. So svojím 140 rokov dlhým pôsobením na trhu však patrí hlavne značka Vaillant k tým najväčším a najvýznamnejším. Dlhodobo je lídrom na trhu a priekopníkom vo vývoji a inováciách v oblasti vykurovacích technológií v Európe. Skupina Vaillant Group má vybudovanú rozsiahlu sieť obchodných zastúpení a tisíce spokojných zákazníkov po celom svete.
Do bohatého portfólia Vaillant Group patria moderné technológie vykurovania, ktoré sú energeticky úsporné, efektívne a prispievajú k ochrane životného prostredia. Vďaka širokému spektru produktov a modelov si tu každý zákazník nájde presne to, čo potrebuje. Sortiment zahŕňa závesné a stacionárne kotly, zásobníky teplej vody či elektrické spotrebiče. Na trhu závesných kotlov je spoločnosť s 26 percentným podielom dokonca číslom jedna v Európe. Vaillant Group sa nešpecializuje len na vývoj a výrobu kotlov, do jej produktového portfólia patria aj technológie využívajúce obnoviteľné zdroje energie, ako sú solárne systémy či najmodernejšie tepelné čerpadlá a klimatizácie. Užívateľom ponúka tiež rekuperačné alebo kogeneračné jednotky či zeolitové tepelné čerpadlá.
Vaillant Group myslí každý deň dopredu a ponúka individuálne riešenia pre každú potrebu a každý druh energie. Jej úspech je založený tiež na výskume a vývoji, ktorý vždy prebieha v súlade so želaniami zákazníkov. Oddelenie výskumu a vývoja spoločnosti patrí k najväčším a predovšetkým k najkreativnejším oddeleniam v tomto segmente. Tím vývojárov neustále pracuje na nových zariadeniach a technologických systémoch, ktoré sa čoraz jednoduchšie obsluhujú a ktoré už dnes spĺňajú požiadavky zajtrajška. Či ide o energetické riešenia budúcnosti, alebo o najlepší spôsob ako využiť fosílne palivá, spoločnosť Vaillant Group sa snaží predvídať nové trendy a byť vždy o krok dopredu pred ostatnými. Dôkazom toho je aj každoročné prihlásenie až 100 nových patentov. V oblasti výroby kladie firma najväčší dôraz na dosiahnutie najvyššej kvality kotlov, ktorá predstavuje dokonalosť do najmenšieho detailu.
Vaillant Group má svoje zastúpenie vo väčšine krajín sveta. Výnimkou nie je ani Slovensko, kde sídli spoločnosť Vaillant Group Slovakia, s. r. o. zastupujúca značky Vaillant a Protherm. Vykurovacie zariadenia Vaillant Group sa vyrábajú v siedmich výrobných závodoch, pričom až dva z nich sa nachádzajú na území našej krajiny. Tieto fabriky zamestnávajú spolu viac ako 1 300 ľudí. Výrobný závod Protherm Production so sídlom v Skalici sa špecializuje na výrobu elektrokotlov a stacionárnych kotlov pre všetky značky patriace do skupiny Vaillant Group. Môže sa pochváliť aj vlastným vývojovým centrom, ktoré patrí k najmodernejším v Európe. Druhým výrobným závodom na Slovensku je Vaillant Industrial Slovakia v Trenčianskych Stankovciach, ktorý pre celú skupinu vyrába moduly pre závesné kotly.
Udržateľnosť
Ako do budúcnosti orientovaný, rodinný podnik, prijímame osobitnú zodpovednosť za životné prostredie, pre našich zamestnancov a pre spoločnosť. Sme presvedčení, že hospodársky úspech, udržateľný a ziskový rast sú neoddeliteľne späté so záväzkom sociálnych a ekologických štandardov.
Aby bolo možné splniť tento záväzok, sme zviazaní plniť naše aktivity trvalo udržateľného rozvoja v strategickom S.E.E.D.S. Program (Udržateľnosť v prostredí, zamestnancoch, rozvoj & produkty a spoločnosť). Definícia tejto oblastí záujmu je založená na komplexnom pochopení udržateľnosti, v ktorej berieme do úvahy aj kľúčové problémy našich hlavných činností.