COMPUTHERM Q4Z

Code: NC-22540
The average product rating is 5,0 out of 5 stars. 1 rating Rating details
143,99 € / pcs Measure price:
1 week

Detailed information

Product detailed description

COMPUTHERM Q4Z zone controller

 

Since boilers are equipped with a connection for only one room thermostat, a zone controller is needed to divide the heating network into several zones, i.e. to control the zone valves and operate the boiler using several thermostats. The zone controller receives the switch-on signals of the thermostats, opens/activates the zone valves/pumps connected to the zone outputs  and starts the boiler.

 

The COMPUTHERM Q4Z 1 – 4 zone controller with an operating switch can ensure the control of a heating zone using a wired thermostat in such a way that individual zones can be operated independently of each other, but if necessary they can also be operated all at once. To control more than 4 heating zones we recommend using two or more zone controllers. In this case, the boiler control outputs must be connected to the boiler in parallel.

 

Any room thermostat with an operating switch can be connected to the zone controller, whose output relay load capacity is: 230V AC; min. 1A (inductive load 0.5A)

 

  • Supply voltage: 230V AC; 50Hz
  • Standby power consumption: 0.3W
  • Zone output voltage: 230V AC; 50Hz
  • Zone output load capacity: 1A (inductive load 0.3A)
  • Boiler control relay load capacity: 230V AC, 50Hz; 5A (inductive load 1A)
  • Boiler control relay delay: 4 minutes

 

The COMPUTHERM Q4Z zone controller complies with the standards: EU EMC89/336/EEC; LVD 73/23/EEC; 93/68/EEC and R&TTE 1999/5/EC.

Frequently Asked Questions

  • How exactly does a manual (simple) thermostat work? It measures the temperature at its installation location and, when it drops below the set value, closes a contact that activates the heat source (boiler, pump, radiator) - once the set temperature is reached, the contact opens again. Unlike programmable thermostats, it has no weekly or daily program; the temperature is set manually with a rotary or slide control.
  • Where should the thermostat be placed? In a location that best represents the average room temperature - away from direct sunlight, drafts, radiators or other heat/cold sources that could distort the measurement.
  • Must installation be carried out by an electrician? Connecting the thermostat to the electrical circuit of the heat source should be carried out by a person with electrical qualifications, since it involves work on the electrical wiring and load switching.

Additional parameters

Category: Computherm controls
Warranty: 2 years
Weight: 1 kg
Boiler control relay delay: 4 minutes
Boiler control relay rating: 230V AC, 50Hz; 5A (inductive load 1A)
Standby power consumption: 0,3W
Supply voltage: 230V AC; 50Hz
Zone output rating: 1A (inductive load 0.3A)
Zone output voltage: 230V AC; 50Hz

Product rating

The average product rating is 5,0 out of 5 stars. 1 rating
5
1x
4
0x
3
0x
2
0x
1
0x

Leave a rating

Do not fill out this field:

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

List of ratings

5
J Avatar of author The product rating is 5 out of 5 stars. | 17/07/2022
Velka spokojnosť so zakupenym tovarom, nejednu vec som už kupil tu v ATRII aj kotol,aj radiátor a stále bezproblémové dodanie, tovar prišiel presne taky aky som si objednal.

Discussion

Do not fill out this field:

List of discussions

P Avatar of author 20/12/2021 10:07
Dobry den, bude zonovy regulator fungovat s termostatom VS30W?
A Avatar of author 20/12/2021 10:07
Dobrý deň. V prípade, ak myslíte Salus, tak áno. Žiaľ, neviem Vám povedať aké to bude mať zapojenie. Pekný deň.