OMNIGENA 32-60 180mm
Code: OMNIGENA 32-60 180MMRelated products
Product detailed description
Circulation pump OMNIGENA 32-60 180mm
- The OMNIGENA range of solar pumps is designed for water circulation in solar and heating systems.
- The pumps can operate in water systems and circuits containing water with glycol in a 50/50 ratio.
- The maximum temperature of the water / water-glycol circuit must not exceed 120 ° C and must not be lower than 5 ° C
- The pumps cannot operate in water systems or circuits containing water with glycol that may contain solid particles (e.g. pieces of rust, etc.).
Pump installation
- It is recommended to install the pump on the return pipe. Ball valves or a filter should be installed immediately before and after the pump.
The pump must be installed so that:
- The required water flow direction should match the arrow shown on the pump housing.
- The circulation pump must always be in a horizontal position. Setting the pump axis in a different position will lead to premature wear of the bearing and pump block.
- Electronics must not be placed under the pump; any water condensation from the motor housing can flood the electrical connections, leading to failure. Pump failure caused by flooding of the connection box is not covered by the warranty.
- The room where the pump will be installed should not contain excessive humidity.
- The pump should be easily accessible for maintenance and venting.
Before starting, make sure the system is filled with water or glycol; the pump must not run "dry". Running "dry" will destroy the pump. Before starting the pump, set the speed to the highest (fastest) setting III, open the drain screw located on the rear wall of the motor and switch on the pump. If air particles are present in the water flow, the pump needs to be vented.
Pump operation and maintenance
The device only requires a check of the pump when commissioning it, or after a longer period of inactivity (e.g. before the heating season). After a long period of rest, check that the motor shaft is not blocked. This should be done as follows: Open the venting screw. At the end of the opening, the end of a cylinder with a cross-section will be visible. Using a flat screwdriver, turn the shaft in the direction indicated on the pump housing. After performing these operations, tighten the venting screw and start the pump at the highest speed level.
Composition:
- pump housing made of cast iron, impeller made of noryl, ceramic shafts
Features and benefits:
- adjustable speed (3 levels)
- quiet operation
- standard installation dimensions
- robust construction
- reliable and simple operation
|
TYPE |
Maximum output [1/min] |
Water head [m] |
Motor power [W] |
Consumption [A] |
|
OMIS 32-60/180 |
65 |
6 |
Level I – 46 Level II – 67 Level III - 93 |
Level I – 0,2 Level II – 0,29 Level III – 0,4 |
Additional parameters
| Category: | OMNIGENA |
|---|---|
| Warranty: | 2 years |
| Weight: | 3 kg |
| Product replaced by new one: | https://www.atria.sk/avansa-32-6-180/ |
| The item has been sold out… | |