Protherm Gepard Condens 25 MKO + WE 100 ME left + Thermolink P
Code: 0010019893Related products
Product detailed description
Protherm Gepard Condens 25 MKO set
+ Gepard Condens 25 MKO - wall-hung condensing boiler with the option to connect a cylinder
+ WE 100 ME left - hot water cylinder, volume: 96 l
+ Thermolink P - eBUS controller
PROTHERM GEPARD CONDENS 25 MKO
- wall-hung condensing boiler with the option to connect an external cylinder
- output: 6,0 - 25,0 kW
- design: turbo
- significant gas savings thanks to condensing technology and continuous output modulation,
- heating comfort using weather-compensated control based on outdoor temperature (equithermal control*),
- instantaneous (flow-through) hot water preparation,
- safety and ease of use thanks to the latest safety functions,
- a simple control panel with a backlit inverse display offering excellent readability even in dark rooms, plus self-diagnostics,
- compatibility with communicating controllers - more savings and comfort.
- low weight and easy installation into the system, whether in a new building or when replacing an older boiler
| Gepard Condens 25 MKO | |
| Heating | |
| Energy class for heating | A |
| Output at 80/60°C flow temp [kW] | 6,0 - 25,0 |
| Output at 50/30°C flow temp [kW] | 6,3 - 26,5 |
| Fuel | natural gas |
| Efficiency at 80/60°C max. output [%] | 98,2 |
| Standardised efficiency rating at 40/30°C [%] | 108,5 |
| Adjustable heating water temperature range [°C] | 10 - 80 |
| Expansion vessel [l] | 8 |
| Max. working pressure [kPa] | 300 |
| Flue gas exhaust | turbo |
| Hot water heating | |
| Output for DHW heating [kW] | 6,0 - 30,0 (applies to water heating in the additional cylinder) |
| DHW supply pressure range [MPa] | - |
| Adjustable DHW temperature range [°C] | 45 - 60 |
| DHW flow rate at Δt 30K [l/min] | - |
| DHW flow rate at Δt 35K [l/min] | - |
| Electrical parameters | |
| Voltage/frequency [V/Hz] | 230/50 |
| Input [W] | 105 |
| Standby input [W] | 2 |
| Electrical protection rating [IP] | IPX4D |
| Dimensions | |
| Unit dimensions (W/H/D) [mm] | 418/740/300 |
| Weight without water [kg] | 31,6 |
PROTHERM WE 100/2 ME
- wall-hung hot water cylinder
- volume: 96 l
- Indirectly heated cylinder a coiled tube heat exchanger
- Net cylinder volume 96 litres
- Wall-hung version suitable for sets with wall-hung boilers
- Built-in electric heating a 2 kW electric heating coil as an additional heating method in case of a boiler fault
- Corrosion protection magnesium anode
- Minimal heat losses thanks to a new type of insulation made of rigid PUR foam
| WEL 100 ME | |
| Energy class for hot water preparation | C |
| Usable water volume | 96 l |
| Max. operating pressure | 800 kPa |
| Heating water connection | G 3/4" |
| Hot water connection | G 1/2" |
| Max. water temperature | 80 °C |
| Maximum output transferable via the cylinder heat exchanger | 19,1 kW |
| Quantity in 10 min. | 135 l |
| Time for the first heat-up of the cylinder (from 10°C to 60°C) | 19 min |
| Height / Diameter | 955 / 469 mm |
| Weight without water | 41 kg |
| Electrical voltage/frequency | 230 V/50 Hz |
| Electrical input | 2 kW |
| Electrical protection rating | IP21 |
| Max. operating temperature | 70 °C |
PROTHERM THERMOLINK P - room communicating controller
eBus programmable the controller allows one weekly programme to be set, with the option of combining up to 7 different time slots with individually adjustable temperatures for both heating and hot water preparation. It allows the heating system to be controlled depending on the room temperature and the set heating programme, or also depending on the outdoor temperature (if an outdoor sensor is connected), with the option of automatic optimisation of the heating curve. A variant of the Thermolink P is the Thermolink RC, with the same features and parameters but with a wireless connection to the boiler.
- Reduces heating costs
- Continuous boiler modulation (eBus)
- Simple controller operation with text prompts on the backlit display
- DHW temperature can be set with a weekly programme
- Automatic weather-compensation curve can be selected
- Optimum heating start to reach the required temperature already at the beginning of the time interval
- Circulation pump control via a weekly programme
- System frost protection
- Display of the current time and day of the week and the current room temperature (or outdoor temperature)
Parameters
| THERMOLINK P | |
| Type | e-BUS |
| Programme type (DHW and heating water) | weekly |
| Number of temperature changes per day | 7 |
| Room temperature setting range | 5 - 30 °C |
| Control characteristic | continuous |
| DHW temperature setting range | 38 - 65 °C |
| Weather-compensation curve setting | yes |
| Automatic heating curve | yes |
| Holiday mode | yes |
| System frost protection | yes |
| Time display | yes |
| Circulation pump control | yes |
| Optimum start | yes |
| Visual low-battery indication | no |
| Connection to the boiler | wired |
Frequently asked questions
- How exactly do I choose the output of a PROTHERM condensing boiler? The starting point is the calculated heat loss of the building being heated (most reliably taken from the project documentation or an energy certificate). If you don't have a project, you can roughly estimate 60-100 W per m² of floor area for a normally insulated house built after 2000, or 100-150 W/m² for an older, uninsulated house - the exact figure varies depending on the number of floors, ceiling height, the number and quality of windows, and the building's orientation. An oversized boiler switches on and off more often (so-called cycling), which shortens its lifespan and reduces efficiency; an undersized boiler, on the other hand, cannot heat the house sufficiently on frosty days.
- Why is a condensing boiler more economical than a conventional one? A condensing boiler also makes use of the heat hidden in the water vapour produced when gas is burned - in a conventional boiler this vapour escapes unused through the flue, while in a condensing boiler it is cooled below the so-called dew point, the vapour condenses, and the released heat is returned to the heating circuit. Thanks to this, condensing boilers achieve an efficiency of roughly 105-110% relative to the calorific value of the gas, compared to the usual 85-92% for conventional boilers.
- What type of flue gas exhaust does this boiler need? Most modern condensing boilers are so-called turbo boilers (with a sealed combustion chamber) and require a concentric (coaxial) or separate flue gas exhaust and combustion air intake routed through an external wall or the roof - so a functional chimney is not required. You will find the exact type and maximum length of the flue (based on a diameter of 60/100 or 80/125 mm) in the technical documentation for the specific model, or you can consult our customer service.
- What does the ErP energy class shown for the boiler mean? This is the mandatory efficiency label for heating appliances under the EU ErP (Ecodesign) directive, similar to the energy labels on refrigerators. Condensing boilers commonly achieve class A, or even higher in combination with room controls (e.g. A+ when using weather-compensated control and a room thermostat).
- Can I install and connect this boiler myself? No. Connecting to the natural gas supply, the electrical network and the flue gas exhaust must, by law, be carried out exclusively by a person with the relevant qualification (most often an authorised service technician of the given brand or a gas appliance inspection technician). After installation, the boiler must be commissioned by the manufacturer's authorised service, which is usually also a condition for the warranty to be valid.
- What about servicing and the warranty? Most manufacturers require a regular annual service inspection by an authorised service provider so that the warranty remains valid even after its standard expiry (an extended warranty subject to regular servicing is common especially for the Vaillant, Protherm and Viessmann brands). You will find the exact warranty terms in the warranty certificate supplied with the boiler.
- What is included in the delivery of this specific product? The exact contents of the package (the boiler itself, possibly a hot water tank, room controls and other accessories in the case of a set) are stated in the product name and in its technical parameters above on this page.
Additional parameters
| Category: | Gepard Condens +100l tank |
|---|---|
| Warranty: | 2 years |
| Weight: | 100 kg |
| Built-in electric heating coil: | 2 kW |
Product rating
Leave a rating
List of ratings
Discussion
List of discussions
O spoločnosti
Spoločnosť Protherm Production patrí do koncernu Vaillant Group a je výrobcom vykurovacej techniky pre mnohé krajiny Európy, Ázie i Afriky. Pre slovenský trh produkuje kotly značiek Vaillant a Protherm. Protherm Production nie je len výrobným závodom. Jeho súčasťou je aj najmodernejšie vývojové centrum, testovacie centrum a distribučno-logistické centrum pre strednú a východnú Európu.
Začiatky spoločnosti siahajú do roku 1991, kedy pôsobila ako predajca vykurovacej techniky v Prahe. Výroba v Skalici bola spustená najprv v spoločnosti Didaktik, odkiaľ bola v roku 1999 presťahovaná do priestorov súčasného závodu. Od roku 2001 sa stala súčasťou nemeckého koncernu Vaillant Group.
Tri slovenské subjekty: Koncern Vaillant Group na Slovensku zamestnáva viac ako 1 800 ľudí. Okrem závodu v Skalici mu patrí aj spoločnosť Vaillant Industrial Slovakia v Trenčianskych Stankovciach, vyrábajúca hydromoduly a rúrky. Predajnou organizáciou pre slovenský trh je spoločnosť Vaillant Group Slovakia, ktorá zabezpečuje i ďalšiu starostlivosť o zákazníka a servis ponúkaných výrobkov.
Koncern Vaillant Group má vyše 140-ročnú históriu a na konte viac ako 2 000 patentov. Je lídrom a priekopníkom v oblasti vykurovacích technológií v Európe. Vo svete má 10 výrobných závodov (osem v Európe, po jednom v Turecku i v Číne) a viac než 12 000 zamestnancov. Vyrába zariadenia značiek Vaillant, Protherm, Saunier Duval, Bulex, AWB, DemirDöküm, Glow-Worm a Hermann.