Product detailed description
Brass manifold for underfloor heating, 2-way, 1" connection.
The manifold is the heart of the entire underfloor (or radiator) heating system - it distributes heating water from a single source (boiler, circulation pump) to the individual circuits, while also allowing each circuit to be regulated, vented and, if necessary, completely shut off separately without affecting the rest of the system. This means that, for example, when repairing one room you can shut off just its circuit while the rest of the house keeps heating.
What makes this manifold stand out
- Complete set ready for installation - shut-off valves, regulating fittings with flow meters, an automatic air vent valve and a drain valve are already included in the delivery; nothing else needs to be purchased apart from the compression fitting for your specific pipe.
- Precise regulation of each circuit separately - the flow meters on the top bar let you set the flow in each loop individually, so you can achieve even heating even with circuits of different lengths.
- Automatic venting - the built-in air vent valve continuously removes air that would otherwise cause bubbling and reduced output.
- Durable brass construction - Press-Messing Ms 58 fitting, nickel-plated, suitable for many years of operation.
Technical parameters
- Number of circuits: 2
- Material: brass, Press-Messing Ms 58 fitting, nickel-plated
- Inlet and outlet connection: 1"
- Branch connection: Ek, Euroconus
- Manifold length without ball valves: 145 mm
- Manifold length with ball valves: 230 mm
- Max. operating pressure: 6 bar (max. test pressure 10 bar)
- Max. operating temperature: + 80 °C
- Flow rate: 1.12 m3/h, measuring range 0-5 l/min, accuracy +/- 10 %
- Thread: DIN ISO EN 228-1
- Seal: EPDM (flat seal WS 3825)
- Suitable fluids: heating water, cooling water, water mixtures with a standard anti-corrosion antifreeze additive
- Purpose: heating and cooling systems
- Country of origin: Slovakia
Step-by-step installation
- Mount the manifold in a cabinet using the supplied brackets (the cabinet is purchased separately, see recommended accessories below) or directly on the wall on a sufficiently solid surface.
- Connect the flow and return from the heat source to the manifold's inlet and outlet (1").
- Screw the compression fitting matching your pipe diameter onto each branch and connect the individual underfloor heating circuits.
- Before starting up, thoroughly fill and vent the system - leave the automatic air vent valve slightly open until only water, with no air, starts to flow out of it.
- Regulate the flow on each circuit using the flow meters so that it matches the length and load of the given loop (longer or more heavily loaded circuits need a higher flow rate).
Recommended accessories
- Pipe: PEX-AL-PEX 16 x 2
- Pipe connection: Compression fitting for ALPEX 16 x 2 ALU-EK pipe
- Placement: Cabinets for manifolds
Frequently Asked Questions
- How do I choose the number of circuits? The number of circuits corresponds to the number of separate underfloor heating loops you want to connect to the manifold - typically one circuit per room, or more circuits for larger rooms.
- What else do I need for installation? A compression fitting to connect the pipe to the manifold (according to your pipe diameter) and a suitable cabinet to house it.
- Can it also be used for cooling? Yes, the manifold is designed for both heating and cooling systems using water or water mixtures with a standard anti-corrosion antifreeze additive.
- What if the exact number of circuits doesn't suit me? Manifolds in this range are available from 2 to 12 circuits, so you can choose exactly according to the needs of your project.
Additional parameters
|
|
Underfloor Heating Manifolds |
|
|
2 years
|
|
|
5 kg
|
|
|
5900308730096
|
|
|
Press-Messing Ms 58, nickel-plated |
|
|
145 mm |
|
|
230 mm |
|
|
Slovensko |
|
|
heating water, cooling water, water mixtures with standard anti-corrosion antifreeze additive |
|
|
mosadz |
|
|
4 - 6 barov |
|
|
+ 80 °C |
|
|
6 barov |
|
|
10 barov |
|
|
PEX-AL-PEX 16 x 2 |
|
|
Compression fitting for ALPEX 16 x 2 ALU-EK pipe |
|
|
Manifold cabinets |
|
|
WS 3825 |
|
|
dva |
|
|
+/- 10 % |
|
|
1,12 m3/h |
|
|
dual-regulation with locking option |
|
|
Ek, Eurokonus |
|
|
1" |
|
|
- 10 °C to 120 °C |
|
|
0-5 l/min |
|
|
EPDM |
|
|
heating and cooling systems |
|
|
DIN ISO EN 228-1 |
|
|
DIN 4109 |
|
|
5900308730096 |
Video Rozdeľovač mosadzný 2 cestný pre podlahové kúrenie
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
Dobrý deň,
áno, produkty, čo ste uviedli, budú spolu fungovať (pasovať k sebe).
Ešte bude potrebný nejaký termostat do izby, postačí manuálny termostat - napríklad tento AVANSA - https://www.atria.sk/avansa-2003/ alebo SASWELL - https://www.atria.sk/saswell-919/.
Pekný deň prajem.
S pozdravom
Dobry den
Chcel by som sa opytat, ci sa da pouzit rozdelovac mosadzny - kod: H4300211 v kombinacii s rozvodnicou SCU 209LED, a elektrotermickou hlavicou na 230V. Zaujimalo by ma, ci tieto hlavice pasuju na tento rozdelovac, alebo tam treba nejaky iny ventil, popripade ak by to nepasovalo, tak ktory rozdelovac by bol vhodny. Dakujem za odpoved.
Dobry den, od SPP som dostal zlavovy kupon na kupu noveho kondenzacneho kotla.Dal by sa tento kupon vyuzit pri kupe kotla od Vas?dakujem za odpoved.Robert
Dobrý deň. Žiaľ u nás nieje možné využiť kupón od SPP.
Je možnost dostat tento plynový kotol i na splátkový kalendár bez navýšenia a kde je najbližšia predajna od Bánoviec n/Bebr.
Žiaľ kotle protherm nieje možné predávať na splátky. Kotol Vám môžme poslať na dobierku. Predajňu protherm v Bánovciach nemáme.
Dobrý deň, je tento kotol možno kombinovať so solárnou zostavou Helioset?
Áno, tento Protherm v tejto verzií KKO sa dá pripojiť s solárku Helioset.
Môžete mi prosím zistiť, aký výkon v kWh má Kotol na zemný plyn Protherm 25 KKO a Plynový ohr. vzduchu LERSEN ALFA ECO 025?
Dobrý deň, výkon kotla na zemný plyn je 24,5 kW a plynový ohrievač lersen alfa nemáme v ponuke.
Dobry den, chcel by som sa spytat ake riesenie by ste mi navrhli. Rodicovsky dom je "klasicky" jednoposchodovy stvorec, nezatepleny, zliatinove radiatory, stary kotol je umiestneny vo verande(turbo), byvame na zahori blizko bratislavy. vyuzivame tiez ohrievanie tuv. chceme tiez vyuzit thermostat, s viacrezimovym vykurovanim. potrebujeme usetrit co najviac energii(stale ich cena stupa). dakujem za vase rady.
Dobrý deň, na otázku som odpovedal v druhom vlákne
Preco je obrazku zobrazney stary typ nekondenzacneho kotla Panther ?
Ďakujeme za upozornenie, bol tam neaktualizovaný obrázok, pekný deň.
Dobry den, Da sa u Vas ku kotolu Protherm Panther Condens 25 KKO vybrat nejaky externy vrstvový zasobnik? Pripadne navrhnite podobny kotol s ext. bivalentnym vrsvovym zasobnikom. Objemom zasobnika okolo 200L.. Dakujem za odpoved.
Dobrý deň, najlepšie máte, keď kúpite originál celu zostavu https://www.atria.sk/kondenzacne-kotly/zostavy-kotol-a-zasobnik/protherm/. Pekný deň.
Aká je záručná doba na tento kotol? Na stránkach PROTHERM-u pri online nákupe uvádzajú 5 rokov. Platí aj pri nákupe u vás? ďakujem. S pozdravom. Peter Nagy
Dobrý deň, štandardná záruka je dva roky, predlžená záruka je vždy možná či už z bežného obchodu, priamo z internetu, alebo od Prothermu ale iba pri dodržiavaní pravidelných servisných kontrol od servisného technika protherm. Pekný deň.
Dobry den, moze mat kotol Protherm Panther Condens 25 KKO splodiny odvedene do komina s pozink vlozkovanim? Alebo je turbo sucastou vyrobku? Dakujem.
Dobry vecer, otazok by som mal viacero, ale aktualne ma trapi toto :) Ideme kupovat novy kotol s moznostou napojenia na externy zasobnik (jestvujuci, takmer novy), kotol (povodny - polofunkcny) aj zasobnik su v pivnici, ale kazdy v inej miestnosti. kotol je spojeny zo zasobnikom plastovymi zateplenymi (tou sivou penovou hmotou) rurkami...vzdialenost cca 3-4m...pocul som nazor, ze ked je externy zasobnik daleko, dochadza tam k "obrovskym stratam" pri udrziavani teplej vody v zasobniku....je to pravda? Jedna sa naozaj o taketo "obrovske straty" oproti tomu, keby som mal nadrz napr. 0,5 m od kotla? (btw. vodu v zasobniku bude dohrievana aj teplovodnym krbom) Dakujem Inak planujem kupit Panther Condens 25 KKO ...je to dobry kotol?
Dobrý deň, Zásobník môže byť aj na streche, ide o to aby bolo potrubie zaizolované a žiadne obrovské straty nehrozia. Čo sa týka kotla Protherm Panther Condens 25 KKO je kvalitný a v dobrej cene. Prajem pekný deň.
Dobry den, mate diely, kominovu zostavu zvisly odvod spalin + 2x 45 stupnove kolena na nizkoteplotny Protherm Panter, 60/100, plech vratane ukoncenia - hlavice, tesnenia so sponami, uchyty plast zdrhovacie pasky, TPT tmel alebo ine vhodne tesnenie- penu do exterieru do stresnej prestupovej tvarovky? Vdaka za info.
Dobrý deň. Je nám ľúto, ale nemáme. S pozdravom
Dobrý deň, rád by som Vás poprosil o radu. Máme rodinný dom. Vykurovacia plocha 120 m2, k tomu mame externý bojler 120 l zavesený na stene. Chceme inštalovať plynový kondenzačný kotol Panther Condenz 25 KKO s vykurovacím výkonom 6,6-26,7 kW alebo či by nebolo lepšie Panther Condenz 30 KKO s rozsahom vykurovacieho výkonu 9,3- 32?8 kW. Ktorý by bol vhodnejší a prosím prečo? Aký je rozdiel v tom, keby sme inštalovali Plynový kondenzačný kotol od firmy Viessmann Vitodens typ 200-W s výkonom 26 kW. Prosíme porovnanie. Za ochotu vyčerpávajúcu a pohotovú odpoveď Vám dopredu ďakujem.
Dobrý deň, na takú malú stavbu Vám kotol Protherm Panther Condens 25 KKO bude bohate stačiť.
Dobry den, idem menit stary plynovy kotol, ktory je napojeny na 1,5rocny 150l boijler a uvazujem bud jednoducho kupim kotol panther, alebo odstavim aj boijler a kupim tiger 25 so 42l, pretoze mate dobru cenu.Viete mi poradit, ktora moznost by bola energiticky uspornejsia?Dakujem
Dobrý deň. Neviem, či sa dá porovnať úspornejšia prevádzka, nakoľko sú oba kotle kondenzačné a majú nízku spotrebu. Kotol Tiger Condenz sa predáva asi najviac. Funguje to tak, že keď sa minie voda v zásobníku, funguje to ako prietokový ohrev. U druhého kotla so zásobníkom sa to nedá tak povedať, tam je potrebné trošku počkať, kým sa voda zohreje znova. Pekný deň
chcem sa spytat chcem kotol panther s prietokovym ohrevom,alebo zasobnikom a rozhodujem sa medzi 25kkv a 25kko.podla dokumentacie sa domnievam ze jeden z tychto dokaze fungovat ako prietokovy a keby to nestacilo tak knemu dokupim zasobnik.je to tak,alebo sa mylim?
vdaka vrstvenym zasobnikom je mozne kombinovat aj kotol Panther Condens 25 KKV z vrstvenym zasobnikom WEL 75ME. Pozrite oficial. cennik na stranke vyrobcu Prortherm ( na dany ucel to vsak musi byt pouzity vrstveny zasobnik z prepojacou sadou, ktore obsahuje aj dobijacie cerpadlo na TV ) Zostava Panther Condens 25 KKV zásobník WEL 75 ME
Dobrý deň, v podstate neexistuje kotol, ktorý by kombinoval prietokový ohrev a ohrev zásobníka. Nedovoluje to konštrukcia kotla, takže bud raz prietokový ohrievač alebo do zásobníka. Avšak môžete k nemu pripojiť akýkoľvek zásobník, takže aj elektrický, ak teda umožňuje pripojenie nejakého iného zdroja. Pekný deň.
ano ale ja ked kupim kotol z moznostou pripojenia zasobnika bude mi najskor fungovat ako prietokovy a ak mi ten prietok nebude stacit tak jednoducho kupim zasobnik?alebo da sa pouzit ako zasobnik 80litrovy elektricky bojler ktory mam?samozrejme ho nedam do elektriky pouzijem ho len ako nadrz.
Dobrý deň, Uvažujem o tomto kotli pre zapojenie do podlahového vykurovania, ktoré má cca. 120m2. Bude expanzná nádoba v kotli (má 8l podľa tech. parametrov kotla) na toto stačiť? Ďakujem. S pozdravom
Dobrý deň. Áno, 8 litrový expanzná nádoba bude bohate stačiť, dokonca aj na väčší dom. Pekný deň
Dobry den. Mam namontovany tento t6p kotla, je spusteny cca 2 tyzdne. Zacal na nom ale stracat tlak, z vecera do rana, z 1, 2 baru - rano 0, 6. Co moze tuto stratu tlaku sposobovat ? Dakujem
Dobrý deň. Tak jednoznačne niekde uniká voda zo systému. Pekný deň.