Product sorting

4 items total

List of products

16903 image HKPE RT
–20 %
2,44 €

PE-RT pipe - panel connection for ceiling heating/cooling pipework - 10x1.3; 200m

HK-PERT10R2
IVARPEXC ST
–19 %
2,49 €

PEX pipe - for wall/ceiling heating - 12x2mm - 240m

28130718
16070 image IVARPEXa B 1
–19 %
5,73 €

PEX pipe - with a thermally insulated jacket - ceiling heating/cooling...

I-PEXA20RCB25
16069 image IVARPEXa R 1
–19 %
5,73 €

PEX pipe - with thermally insulating jacket - ceiling heating/cooling pipework -...

I-PEXA20RCR25

Listing controls

4 items total
IVAR.PE-Xc-ST - PEX pipe 
  • PN 6 at T = +90 °C, PN 10 at T = +60 °C
  • designed for wall or ceiling heating distribution
  • connected using an IVAR.TP 4410 12 x 2 mm compression fitting
  • material: cross-linked polyethylene with an oxygen barrier

PEX pipe - for wall/ceiling heating - 12x2mm - 240m

IVAR.PE-Xa RCB, IVAR.PE-Xa RCR - PEX pipe with insulating jacket

  • PN 10, T = +95 °C
  • Use: for main distribution lines of IVARCLIMA radiant ceiling heating / cooling
  • pipe material: cross-linked polyethylene with an oxygen barrier
  • thermal insulation material: low-density polyethylene (PE-LD) with a closed cell structure and protective film, red and blue colour

PEX pipe with insulating jacket for radiant ceiling heating/cooling distribution - 20 x 2; bluePEX pipe with insulating jacket for radiant ceiling heating/cooling distribution - 20 x 2; blue

IVAR.HK PE-RT, IVAR-HK PE-RT - PE-RT pipe
  • PN 10, T = +70 °C
  • Use: for connecting IVARCLIMA radiant ceiling heating / cooling panels to the distribution system
  • material: polyethylene with an oxygen barrier

PE-RT pipe - for connecting panels to radiant ceiling heating/cooling distribution - 10x1.3; 200m

Frequently Asked Questions

  • What is the difference between PEX and PE-RT pipe? PEX (cross-linked polyethylene) has higher thermal and pressure resistance thanks to the cross-linking of chains, while PE-RT (heat-resistant polyethylene) is more flexible and easier to handle when installing connecting branches to the panels.
  • Why does the pipe have colour coding (blue/red)? The colour only makes it easier to distinguish between the flow and return pipes during installation of the distribution system; it has no effect on functionality.
  • What does a thermally insulating jacket on the pipe mean? A jacketed pipe reduces heat loss when routed through unheated spaces or when running several circuits alongside each other.
  • Is the pipe also suitable for cooling? Yes, both PEX and PE-RT pipes with an oxygen barrier can withstand the normal operating temperatures of both the cooling and heating circuits of surface systems.