Thermostatic mixing valve for DHW - 3/4“; Kv 1,9; + 36° C to + 50° C

Code: 507035
napojeny tovar
Not rated Rating details
130,38 € –20 %
22688 termostaticky zmiesavaci ventil pre tv 3 4 kv 1 9 36 c az 50 c
130,38 € –20 % 104,30 € / pcs Measure price:
1 week

Detailed information

Product detailed description

Thermostatic mixing valve for DHW, IVAR.MIX T5, size: 3/4", setting: +36˚ C to +50˚ C

 

  • PN 10, T = +90°C
  • IVAR.MIX T5 – continuous setting range +36 °C to +50 °C
  • protection against limescale build-up
  • material: nickel-plated brass CW617N

 

Note: F - cold water inlet, C - hot water inlet

Frequently Asked Questions

  • How do I choose the right type and size of fitting/valve? Follow the nominal pressure (PN) and operating temperature (T) stated in the technical parameters - they must match or exceed the actual operating conditions of your system, and the connection size must match the pipe diameter.
  • How does this fitting/valve work? The exact operating principle (shut-off, pressure regulation, return flow, etc.) depends on the specific type - a detailed description of the function can be found above for this product.
  • Must installation be carried out by a professional? Simple shut-off fittings can be installed even by a skilled home handyman, but for control and safety fittings (safety valves, pressure-reducing valves) we always recommend a professional, as these are components with a safety function.

Additional parameters

Category: mixing valves for DHW
Warranty: 2 years
Weight: 0.668 kg
EAN: 507035
Material type: nickel-plated brass CW617N Note
Operating temperature: +90°C
Nominal pressure: PN 10
Last price update: 13.04.2026 1:04:50

Product rating

Be the first who will post an article to this item!

Do not fill out this field:

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Do not fill out this field:

List of discussions

J Avatar of author 18/01/2022 07:50
Dobrý deň Potreboval by som zmiešavací termostatický ,ideálne mechanicky ventil ktorý by mi púšťal do iba kúrenia prednastavenú konstatnu teplotu vody napríklad 60 stupňov,resp tu teplotu ktorú by som si navolil aj v prípade že budem kúriť na 80-90 stupňov a prebytok teploty by mi hneď smerovalo do akumulačnej teploty a po vyhasnutí v kotli mi zase bude púšťať takto nastavenú teplotu z akumulačnej nádoby.. .Bude toto takto fungovať? Ďakujem
A Avatar of author 18/01/2022 07:53
Dobrý deň, áno bude to fungovať, ale na to sa dáva zmiešavací ventil https://www.atria.sk/vykurovacia-technika/kurenie-profesionalne/regulacne-a-poistne-armatury/zmiesavacie-ventily/ a servo https://www.atria.sk/vykurovacia-technika/kurenie-profesionalne/regulacne-a-poistne-armatury/servopohony-k-ventilom-mix/, plus regulácia adex https://www.atria.sk/regulacia-adex-comfort-12/ Prajem pekný deň.
J Avatar of author 18/01/2022 07:53
Dobry den A ked som tak na to este pozeral to zdaleka nieje cela investicia,asi bude treba este dokupit servopohony na gulove ventily Ta regulacia podla popisu dokaze vela ale ,neviem si prestavit ako zabrani po vyhasnuti kotla tomu aby teplo z AKU neprehanalo cez kotol a na zakladade coho a ako by rozpoznala ze teplo v systeme je z kotla a nie z akumulacky..Vie to vobec rozpoznat? Dik
A Avatar of author 18/01/2022 07:52
Dobrý deň, ešte ma napadlo : https://www.atria.sk/vykurovacia-technika/kurenie-profesionalne/regulacne-a-poistne-armatury/termoreg-prepustacie-ventily/ alebo s čerpadlom : https://www.atria.sk/vykurovacia-technika/stacionarne-kotly-a-zasobniky/klasicke-a-splynovacie-kotly/ladomaty-regulacie/ Pekný deň.
J Avatar of author 18/01/2022 07:52
Dobry den Dakujem.Tie termo ventily..To su tie co sa pouzivaju na ochranu spiatocky na kotloch.??
A Avatar of author 18/01/2022 07:52
Áno to sú tie.
J Avatar of author 18/01/2022 07:51
Dobry den No jeden mam tiez na kotli na spiatocke (esbe) ale ci by to fungovalo aj tuto ..,veru neviem .Ja na nich nastavena minimalna teplota ale potreboval by som osetrit MAX teplotu.Ci robia sa aj v opacnom prevedeni s preddefinovanou MAX teplotou? Preco?Mam od Vas nakupenu tu sedu penovu izolaciu na potrubiach a kedze kurim do akumulacky,niekedy aj 95° tak mi tu izolaciu pravidelne zoskvari a odpadne a tak by som tomuto rad predisiel..Mam tam sice 3cestny zmiesavaci ventil ,tiez esbe ale na nom sa neda nastavit teplota ,teplotu ktoru pusta do systemu , ta sa priebezne meni v zavislosti od teploty kotla,intenzity v ohnisku a nemam cas stale stat pri kotli a regulovat ventil..tak preto hladam jednoduchsie a hlavne mechanicke riesenie... Dakujem
A Avatar of author 18/01/2022 07:51
Dobrý deň, v opačnom nie tam sa dáva potom regulátor - adex uvedený nižšie : https://www.atria.sk/regulacia-adex-comfort-12/ Ak jednoduchšie tak jednoznačne ten ventil čo som písal a maximálnu teplotu to neviem ohraničiť. Prajem pekný deň.
J Avatar of author 18/01/2022 07:51
Dobry den Prosim Vas..zhanam termostat spalin,alebo kominovy..Nieco co mi bude podla teploty kominovej rury spustat a vypinat kotlove cerpadlo..Mate take nieco v ponuke?Nic take som tu na Vasej stranke nenasiel..
A Avatar of author 18/01/2022 07:50
Dobrý deň, skúste si pozrieť : https://www.atria.sk/prilozny-termostat-emos-s-kapilarou/ Prajem pekný deň.