Pipe cap PRESS - C - 42mm

Code: IVC50.42
napojeny tovar
Not rated Rating details
17,47 € –19 %
43661 viecko potrubia press c 42mm
17,47 € –19 % 13,98 € / pcs Measure price:
1 week

Detailed information

Product detailed description

Cap for pipe installation, IVAR.IVC50, size: 42 mm, package: 10 pcs 

 

  • PN 16, T = -20 °C to +85 °C - max. +120 °C
  • pipe cap PRESS
  • purpose of use: for heating systems, permanently flooded sprinkler systems,
    pressurized dry air, inert gases and industry
  • material: carbon galvanized steel, EPDM O-ring
  • Compatible with type M jaws

 

Note: Does not contain substances that impair the surface coating; leaks if not properly pressed
and has a press-fit indicator up to size 54 mm.
 
 
Areas of use
 
  •  installation of central heating pipework in a closed (pressurized) system
  •  installation of cold water and cooling pipework
  •  installation of fire-fighting water pipework
  •  installation of air-conditioning pipework
  •  installation of pipework for solar systems
 
 
Advantages
 
  •  fast and safe installation without welding or making threaded joints
  •  wide range of pipe and fitting diameters from 15 mm up to 108 mm
  •  wide operating temperature range -20 C to +180 C
  •  resistance to high pressures up to 16 bar
  •  possibility of combining with other systems
  •  low weight of pipes and fittings
  •  high aesthetic quality of installation
  •  resistance to mechanical damage

 


The pipe is not certified for drinking water.

 

Frequently asked questions

  • What tools do I need to install this fitting? Press fittings require specialized pressing pliers with the correct jaw type (commonly marked B, F, or TH depending on the system) matching the size and type of fitting - without the correct tool the joint cannot be made or checked.
  • How do I know the joint has been pressed correctly? Quality press fittings have a press indicator (e.g. a sealing O-ring that leaks if pressing is not completed) - before embedding in a wall or screed, a pressure test of the entire system must always be carried out.
  • Can the joint be taken apart after pressing? No, unlike a screwed (compression) connection, a pressed joint is permanent and taking it apart requires cutting off the fitting and replacing it with a new one.
  • Must the installation be carried out by a professional? Yes, pressing fittings requires professional skill and correctly calibrated tools - we recommend leaving it to a heating engineer/plumber, especially for joints that will be embedded in a wall or screed with no possibility of later inspection.

Additional parameters

Category: IVAR.IVC50, IVC51 - cap, plug
Warranty: 2 years
Weight: 0.116 kg
Material type: galvanized carbon steel
Operating temperature: -20 °C
High-pressure resistance up to: 16 bar
Nominal pressure: PN 16
Last price update: 13.04.2026 1:06:42